AC
Voltage Range (50Hz to 500Hz) |
1.3V
to 750.0V |
|
AC
Voltage Basic Accuracy |
±(1.5% of Rdg + 3
digits) |
|
Overload Protection |
750V
rms |
| |
|
AC Current (50/60Hz) Range |
|
AC Current Basic Accuracy
|
0.0 to 60A |
|
60.0 to 400.0A |
|
401 to 500A |
|
501 to 600A |
|
|
0 to 600A |
|
±(1.9% of Rdg + 2A) |
|
±(1.9% of Rdg + 5A) |
|
±(2.5% of Rdg + 7A) |
|
±(3.0% of Rdg + 10A) |
|
|
Overload Protection |
0 to
500 amps continuous operation |
|
|
|
DC
Voltage Range |
1.8V
to 1000V |
|
DC
Voltage Accuracy |
±(1.0% of Rdg + 2
digits) |
|
Overload Protection |
1000V
DC |
|
|
|
Resistance |
0 to
2000 Ohms |
|
Resistance Accuracy (0.0Ω
to 99.9Ω) |
±(2.0% of Rdg + 1Ω)
|
|
Resistance Accuracy (100Ω
to 2000Ω |
±(2.0% of Rdg + 2
digits) |
| |
|
General Specifications |
|
Display |
6000
digit large scale liquid crystal display (LCD) |
|
Refresh Rate |
5
times per second |
|
Overrange Display |
'OL'
displayed |
|
Automatic Power Off Time |
Approx. 30 minutes after power-on Low Battery
indication. |
|
The
battery symbol is displayed when the battery voltage |
|
drops
below the required level |
|
Power |
Single 9V battery NEDA 160A |
|
Battery Life |
250
hours with an Alkaline battery |
|
Operating Temperature |
0°C
to 30°C 80% R.H. CAT II |
|
30°C
to 40°C 75% R.H. CAT II |
|
40°C
to 50°C 45% R.H. CAT II |
|
Storage Temperature |
-20°C
to 60°C, 0 to 80% R.H.
(battery removed) |
|
Conductor Size |
32mm
(1.3") diameter |
| |
|
Included Accessories
|
|
Test Leads, Battery
(installed), Users Manual, and Carrying Case. |