Specifications |
|
AC Voltage |
4.000V, 40.00V,
400.0V, 600V |
|
AC Voltage
Accuracy |
±1.5% of Reading + 5 digits @
(4.000V, 40.00V, 400.0V) |
|
|
|
DC Voltage |
0 to
400.0mV,4.000V, 40.00V, 400.0V, 600V |
|
DC Voltage
Accuracy |
±0.5% of Reading + 3 digits @
(4.000V, 40.00V, 400.0V) |
|
|
|
AC Current |
0 to 40.00A,
400A |
|
AC Current
Accuracy |
±1.9% of Reading + 8 digits* |
|
|
|
AC/DC Micro
Amps (using test leads) |
400µA,
2000µA |
|
AC Micro Amp
Accuracy |
±2.0% of Reading + 5 digits |
|
DC Micro Amp
Accuracy |
±1.5% of Reading + 4 digits |
|
|
|
Resistance
(with continuity buzzer) |
0 to 400.0Ω,
4.000kΩ, 40.00kΩ, 400.0kΩ |
|
Resistance
Accuracy |
±0.6% of Reading + 4 digits @ (4.000kΩ,
40.00kΩ, 400.0kΩ) |
|
|
|
Capacitance |
500nF, 5.000µF,
50.00µF, 500.0µF, 3000µF |
|
Capacitance
Accuracy |
±3.5% of Reading + 6 digits |
|
|
|
Frequency
(using Jaw or Test Leads) |
10Hz to 100kHz |
|
Frequency
Accuracy |
±0.5% of Reading + 4 digits |
|
|
|
Temperature |
-20°C
to 300°C (-4°F
to 572°F) |
|
Temperature
Accuracy |
±2.0% of Reading + 6°F |
| |
|
*Accuracy
specified to 350A continuous, and 400A for 60-second max with
5 minutes cool down interval.
**Added range to indicate instantaneous over-range current
values TRMS model ACD-14 TRMS FX accuracy is specified from
10% to 100% of range. |
| |
|
General Specifications |
|
Size
|
190mm (L) x
63mm (W) x 32mm (D)
7.48" (L) x 2.48" (W) x 1.25" (D) |
|
Weight |
204g (0.450 lb)
approx. |
|
Safety |
CE, CAT III
600V |
|
Battery Life |
98 hours
approx. (in DCV mode) |
|
Warranty |
Limited
Lifetime |
| |
|
Optional Accessories |
|
Part # A47L |
Power Line
Splitter and Energizer |
|
Part #
CT50-1 |
Amptran 5000A
Clamp-On Current Transformer (50:1) |
|
Part #
CT50-2 |
Amptran 3000A
Clamp-On Current Transformer (50:1) |
|
Part # A50-1 |
Deca-Tran 600A
Clamp-On Current Transformer (10:1) |
|
Part #
ACF-3000AK |
3000A Flexible
Current Transducer |
|
Part # TMA-K |
Temperature
Adapter |
|
Part #
VRC-320 |
Set of Push-On
Alligator Clips |
| |
|
Included Accessories |
|
Set of Test Leads, Type-K