Specifications |
|
AC
Current Range |
400.0A,
2000A |
|
AC
Current Basic Accuracy |
±(1.5% of Rdg + 5 digits)
50/60Hz |
|
AC
Voltage Range |
6.000V,
60.00V, 600V |
|
AC
Voltage Basic Accuracy |
±(2.0% of Rdg + 5 digits)
50/60Hz |
| |
|
DC
Voltage Range |
6.000V,
60.00V, 600V |
|
DC
Voltage Basic Accuracy |
±(2.0% of Rdg + 5 digits)
|
| |
|
Resistance Ranges |
6.000Ω,
60.00Ω, 600.0kΩ, 6.000MΩ |
|
Resistance Basic Accuracy |
±(1.0% of Rdg + 4 digits)
60.00 to 600.0kΩ |
|
Frequency |
10Hz to
1kHz (0.5% +4 digits) |
|
Capacitance Ranges |
100.0nF,
1000nF, 10.00µF, 100.0µF,
2000µF (3.5% +5 digits) |
|
Non-contact Voltage |
15V to
85V, 40V to 130V, 60V to 210V, 90V to 300V, Above 120V |
| |
|
General
Specifications |
|
Display |
3-5/6
digits 6000-count LCD display |
|
Refresh Rate |
5 per
second nominal |
|
Polarity |
Automatic |
|
Low
Battery |
Below 2.4
volts approx. |
|
Operating Temperature |
0°C
to 40°C |
|
Relative Humidity |
Max R.H.
80% for temperature up to 31°C
decreasing |
|
linearly
to 50% R.H. at 40°C |
|
Storage Temperature |
-20°C
to 60°C, <80% R.H. (with
battery removed) |
|
Temperature Coefficient |
Nominal
0.15 x (specified accuracy)/°C
at |
|
(0°C
to 18°C or 28°C
to 40°C), or otherwise
specified |
|
Sensing |
True RMS |
|
Safety |
Meets
EN61010-1: 2001; IEC61010-2-032 (1994), |
|
EN61010-2-032 (1995), UL3111-2-032 (1999), |
|
CAT III
600 Volts AC/DC |
|
Transient Protection |
6.5kV
(1.2/50µs surge) |
|
Pollution Degree |
2 |
|
EMC |
Meets
EN61326-1 |
|
Power
Supply |
Two 1.5V
size 'AAA' (NEDA 24G or IEC R03) batteries |
|
Power
Consumption |
2.2mA
typical |
|
Jaw
opening/Conductor size |
45mm
maximum |
|
Size |
224mm (L)
x 78mm (W) x 40mm (D) |
|
Weight |
220g
approx. |
| |
|
Included Accessories
|
|
Test Leads, Batteries