Rapid-Tech Equipment Logo Combo Kit Power Quality Recorder Power Quality Analyzer Multifunction Digital Multimeter

Nationwide - Call 1800 358 531 

Amprobe logo

ACD-41PQ
Power Quality Clamp-Meter


The ACD-41PQ provides a simple and effective way to verify if the electrical system is affected by harmonics. Get complete Power analysis with the ACD-41PQ and increased measuring efficiency with an optional PC interface kit.
 

ACD-41PQ Power Quality Clamp-Meter

Features
  • TRMS sensing.
  • Total Harmonics Distortion THD, AC/DC Voltage up to 600V, AC Current up to 1000A.
  • Peak and Data Hold.
  • Temperature
  • Resistance Measurements.
  • Frequency Measurements.
  • Active (W), Reactive (VAR) and Apparent (VA) Power with Power Factor.
  • Optional PC interface capacity (RS-232 KIT2).
  • Audible continuity.
  • Auto Power Off.
  • Automatic Polarity.
  • Low Battery Indication.
  • Measurement Category CAT III 600V (AC/DC)
  • Voltage overload protection for all functions up to 600V AC/DC.
  • Large easy to read LCD display with backlight.
  • Accommodates conductors up to 45mm (1.77") in diameter.

Safety Conformity

Specifications

True RMS

True RMS sensing

AC Voltage

600.0V

AC Voltage Basic Accuracy

±(0.5% of reading + 5 digits) at 50/60Hz

AC Current

40.0A, 400.0A, 1000A

AC Current Basic Accuracy

±(1.0% of reading + 5 digits) at 50/60Hz

 

DC Voltage

600.0V

DC Voltage Basic Accuracy

±(0.5% of reading + 5 digits)

 

Resistance

999.9 Ohms

Resistance Basic Accuracy

±(1.0% of reading + 6 digits)

Frequency

5.00Hz to 500Hz

Frequency Basis Accuracy

±(0.5% of reading + 4 digits)

 

THD-F

0.0% to 99.9%

THD-F Basic Accuracy

1.5% of Rdg = 6 digits at Fund Frequency

 

Active Power (W)

0 to 600.0 kW

Active Power (W) Basic Accuracy

±(2.0% of rdg + 6 digits) at Harmonics Fund to 10th and PF>0.7

Reactive Power (VAR)

0 to 600.0 kVAR

Reactive Power (VAR) Basic Accuracy

±(2.0% of rdg + 6 digits) at Harmonics Fund to 10th and PF>0.7

Apparent Power (VA)

0 to 600.0 kVA

Apparent Power (VA) Basic Accuracy

±(2.0% of rdg + 6 digits) at Harmonics Fund to 10th

 

Power Factor

0.10 to 0.99

Power Factor Basic Accuracy

±3 digits at Harmonics Fund to 21th

 

Temperature

-50°C to 300°C (-58°F to 572°F)

Temperature Basic Accuracy

±(2.0% of Rdg + 3°C), ±(2.0% of Rdg + 6°F)

 

Sampling Rate  

1 per second (Power Function)

4 per second (Voltage, ACA clamp-on, Hz and Temp Functions)

Polarity

Automatic

Low Battery

Below 2.4V approx.

Transient Protection

6.5kV (1.2/50μs surge)

Pollution

Degree 2

E.M.C.

Meets EN61326 (1997, 1998/A1), EN61000-4-2 (1995), and

EN61000-4-3 (1996) an RF field of 3V/m:

Specified Accuracy + 45 digits

performance above 3V/m is not specified

 

General Specifications

Operating Temperature

0°C to 40°C

Storage Temperature

-20°C to 60°C, <80% R.H. (battery removed)

Power Supply

Standard 1.5V 'AAA' size (NEDA 24A or IEC LR03) battery x 2

Power Consumption

10mA typical (Voltage, ACA, Hz and Power Functions)

4mA typical (HM and Temperature functions)

Size

224mm (L) x 78mm (W) x 40mm (D)

Weight

224g approx

 

Included Accessories

Users Manual, Batteries, Thermocouple, Carrying Case and Test Leads

 

Optional Accessory

RS-232 KIT2 Data recording System

 


Fluke | Hart | Reed | Yokogawa | EuroSMC | Kyoritsu | Megger | | Tenmars | Tektronix | Amprobe | CIE | Silvertronic |
 Site Map | Search | About Us | Contact Us

 

Rapid-Tech Equipment
ABN 79 883 184 102
1300 Ferntree Gully Road. Scoresby. Victoria 3179
P.O. Box 4243 Knox City Centre. Victoria 3152

Phone: +61 3 9763 3299     Fax: +61 3 9753 2132