Rapid-Tech Equipment Logo Combo Kit Power Quality Recorder Power Quality Analyzer Multifunction Digital Multimeter

Nationwide - Call 1800 358 531 

Amprobe logo

AM-150 True-rms Precision DMM

 

AM-150 True-rms Precision DMM

Features
  • True RMS measurements
  • Optical isolated PC interface capability
  • Auto and manual ranging
  • Auto power 'Off'
  • Data Hold
  • Peak Hold
  • Auto and Manual Ranging
  • Backlight Display
  • Large, easy to read LCD display
  • Auto compensation of the test lead resistance
  • Diode Test
  • Audible continuity
  • Safety CAT III, 1000V, CAT IV 600V

Safety Conformity

 

Specifications

AC Voltage Ranges  (50/60Hz)

50.00mV, 500.0mV, 5.000V,50.00V, 500.0V,1000.0V

AC Voltage Accuracy

±(0.5% of Rdg + 3 digits)

AC Current Ranges (50 to 60Hz

500.0/5000µA, 50.00/500.0mA, 5.000/10.00A

AC Current Accuracy

±(1.0% of Rdg + 4 digits)

DC Voltage Ranges

50.00mV, 500.0mV, 5.000V,50.00V, 500.0V,1000.0V

DC Voltage Accuracy

±(0.08% of Rdg + 2 digits)  5V to 1000V range

DC Current Ranges

500.0µA, 5000µA, 50.00mA, 500.0mA, 5.000A, 10.00A

DC Current Accuracy

±(0.2% of Rdg + 4 digits)

Resistance Ranges

50.00Ω, 500.0Ω, 5.000kΩ, 50.00kΩ, 500.0kΩ, 5.000MΩ, 50.00MΩ

Resistance Accuracy

±(0.02% of Rdg + 6 digits) for 50Ω to 500kΩ range

Frequency Ranges

6Hz to 20kHz

Accuracy

±(0.1% of Rdg + 2 digits) for 50 volt range

Capacitance Ranges

50.00nF, 500.0nF, 5.000µF, 50.00µF, 500.0µF, 9999µF

Accuracy

±(2.0% of Rdg + 3 digits) for 50nF to 50µF range

Temperature Ranges

-50°C to 1000°C (-58°F to 1832°F)

Accuracy

±(0.3% of Rdg + 1°C), (±(0.3% of Rdg + 2°F)

Duty Cycle

0.1% to 99.99% ±(3 digits/kHz + 2 digits)

 

General Specifications

Display

3-4/5 digits 5000 counts LCD display

Display Refresh Rate

5 per second nominal, 60 per second for 52 segment Bar-graph display

AC Sensing

True RMS

Operating Temperature

0°C to 45°C

Storage Temperature

-20°C to 60°C, 80% R.H. (with battery removed)

Relative Humidity

Max. R.H. 80% for temperature up to 31°C decreasing linearly

to 50% R.H. at 45°C

Pollution Degree

2

Overload Protection (µA and mA)

1A/1kV (or 0.44A/1kV), IR 10kA, F fuse

Overload Protection (Amps)

15A/1kV, IR 10kA (or 11A/1kV, IR 20kA), F fuse

Overload Protection (mV, V, other)

1050Vrms/1450Vpeak

Power Supply

Single Alkaline 9 volt battery

Power Consumption

2.6mA Typical

Low Battery

Below 7 volts approx.

Dimensions

193mm (L) x 97mm (W) x 46mm (D)

Weight

370g

 

Included Accessories

Included Accessories

Test leads, Battery (installed), Thermocouple and User manual

 


Fluke | Hart | Reed | Yokogawa | EuroSMC | Kyoritsu | Megger | | Tenmars | Tektronix | Amprobe | CIE | Silvertronic |
 Site Map | Search | About Us | Contact Us

 

Rapid-Tech Equipment
ABN 79 883 184 102
1300 Ferntree Gully Road. Scoresby. Victoria 3179
P.O. Box 4243 Knox City Centre. Victoria 3152

Phone: +61 3 9763 3299     Fax: +61 3 9753 2132