| Specifications (Accuracies at 23°C
5°C, <75% R.H.) |
|
AC Voltage Ranges
(40 to 400Hz) |
400mV, 4V, 40V, 400V,
600V |
|
Accuracy (400mV
Range) |
±(1.5% of Rdg + 3 digits) (resolution 0.1mV) |
|
Accuracy
(4V,40V,400V Range) |
±(1.0% of Rdg + 2 digits) (resolution 1mV, 10mV, 100mV |
|
respectively) |
|
Accuracy (600V
Range) |
±(1.5% of Rdg + 3 digits) (resolution 1V) |
|
Impedance |
10MΩ,
More than 100MΩ on 400mV range |
|
AC Current Ranges
(40 to 400Hz) |
400µA,
4000µA, 40mA, 400mA, 4A, 10A |
|
Accuracy (400µ,
4000µA, 40mA, 400mA Ranges) |
±(1.5% of Rdg + 3 digits) (resolution 0.1µA,
1µA, 10µA,
100µA, respectively) |
|
Accuracy (4A, 10A
Ranges) |
±(2.5% of Rdg + 5 digits) (resolution 1mA and 10mA
respectively) |
|
DC Voltage Range |
400mV, 4V, 40V, 400V,
600V |
|
Accuracy (400mV,
4V, 40V, 400V Ranges) |
±(0.5% of Rdg + 2 digits) (resolution 0.1mV, 1mV, 10mV, 100mV
respectively) |
|
Accuracy (600V
Range) |
±(0.8% of Rdg + 3 digits) (resolution 1V) |
|
Impedance |
10MΩ,
More than 100MΩ on 400mV range |
|
DC Current Ranges |
400µA,
4000µA, 40mA, 400mA, 4A, 10A |
|
Accuracy (400µA,
4000µA, 40mA, 400mA Ranges) |
±(1.2% of Rdg + 3 digits) (resolution 0.1µA,
1µA, 10µA,
100µA respectively) |
|
Accuracy (4A, 10A
Ranges) |
±(2.0% of Rdg + 5 digits) (resolution 1mA, 10mA respectively) |
|
Resistance Ranges |
400Ω,
4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ |
|
Accuracy (400Ω,
4kΩ, 40kΩ, 400kΩ, 4MΩ Ranges) |
±(1.0% of Rdg + 2 digits) (resolution 0.1Ω,
1Ω, 10Ω, 100Ω, 1kΩ respectively) |
|
Accuracy (40MΩ
Range) |
±(2.0% of Rdg + 3 digits) (resolution 10kΩ) |
|
Capacitance Ranges |
40nF, 400nF, 4µF,
40µF, 400µF,
4000µF |
|
Accuracy (40nF
Range) |
±(3.0% of Rdg + 10 digits) (resolution 10pF) |
|
Accuracy (400nF, 4µF,
40µF Ranges) |
±(2.5% of Rdg + 5 digits) (resolution 100pF, 1nF, 10nF
respectively) |
|
Accuracy (400µF
Range) |
±(5.0% of Rdg + 10 digits) (resolution 100nF) |
|
Accuracy (4000µF
Range) |
±(20.0% of Rdg + 20 digits) (resolution 1µF) |
|
Frequency Ranges |
10Hz, 100Hz, 1000Hz,
10kHz, 100kHz, 1000kHz, 10MHz |
|
Accuracy |
±(0.1% of Rdg + 5 digits) (resolution 0.01Hz to 10kHz |
|
Sensitivity Sine
wave |
0.6V RMS (10MHz: 1.5V
RMS) |
|
Duty Cycle |
0.1% to 99.9% |
|
Temperature Range |
-50C to +700C |
|
Accuracy |
±(1% + 2°C) Resolution 1° |
| Note: Accuracy specification is
relative to the user-adjustable offset, and assumes ambient
temperature stable to For ambient temperature changes of
±5°C, rated
accuracy applies after 1 hour. Does not include error of the
thermocouple probe. |
| |
| General Specifications |
|
Display |
LCD with a maximum
reading of 4000-counts |
|
Range Control |
Auto range and manual
range control. |
|
Polarity |
Automatic |
|
Zero Adjustment |
Automatic |
|
Overload
Indication |
Yes Displays sign |
|
Low Battery
Indication |
Yes Displays sign |
|
Data Hold Display |
Yes Displays sign |
|
Relative
Measurement |
Yes Displays sign |
|
Auto Power Off |
Yes |
|
Operating
Temperature |
0°C
to 40°C (32°F
to 104°F) Humidity <80% R.H. |
|
Storage
Temperature |
-20°C
to 60°C (-4°F
to 140°F) Humidity <90% R.H. |
|
Safety |
CE EMC/LVD. The
instrument is up to the standards of |
|
EN 61010-1:2001;
Double Insulation, Pollution 2, Overvoltage |
|
Category III-600V. |
|
Power Supply |
Two 1.5V Type 'AA'
batteries |
|
Dimensions |
156mm (H) x 86mm (W)
x 38mm (D) |
|
6.1" (H) x 3.4" (W) x
1.5" (D) |
|
Weight |
260g (9.2 oz) approx.
including battery |
| |
|
Included Accessories |
|
Included Accessories |
Test leads, battery (installed), and
user manual |
|