Specifications
(Accuracies are specified as ±(...% of reading
+ ...digits) at
23°C ±5°C, <80% R.H. |
|
|
|
Insulation Resistance |
| Voltage
Range |
Resistance
Range |
Resolution |
Accuracy |
Test
Voltages |
|
250v |
40MΩ to 400MΩ |
40MΩ: 10kΩ
400MΩ: 100kΩ
4000MΩ: 10MΩ |
3% +5 (<1000MΩ)
5% +5 (>1000MΩ) |
250V +20%
~ -0% |
|
500V |
400MΩ to
1000MΩ |
500V +20%
~ -0% |
|
1000V |
400MΩ to
2000MΩ |
1000V +20%
~ -0% |
|
Analog Bar Graph |
0 to 4000MΩ |
|
Nominal Current |
≥ 1mA |
|
| |
|
Resistance and Continuity
(<40Ω) |
| Resistance
Range |
Resolution |
Accuracy |
Max. open
Circuit |
Overload
Protection |
| 999.9Ω |
0.1Ω |
1% +2 |
3V |
1000Vrms |
|
| |
|
General Specifications |
|
Display: |
Dual Display, 3-3/4 digit readout
with bar graph |
|
Sample Rate: |
2-1/2 samples/second |
|
Manual Data Memory and Read: |
Memory capacity 9 sets data |
|
Safety: |
CAT III, 1000V |
|
Pollution Degree: |
2 |
|
Over-range Indicator: |
'OL' will be displayed |
|
Power Supply: |
6 x 1.5V size 'AA' batteries |
|
Operating Temperature: |
0°C to 50°C
(32°F to 122°F) <80% R.H. (non-condensing) |
|
Storage Temperature: |
-10°C to 60°C
(14°F to 140°F) <70% R.H. (non-condensing) |
|
Dimensions: |
235mm (L) x 116mm (W) x 54mm (D) |
|
9.3" (L) x 4.6" (W) x 2.1" (D) |
|
Weight: |
520gms (!.15 lb), including
batteries |
|
| |
|
Included
Accessories |
|
Included Accessories |
Test Leads, batteries, holster
and operation manual |
|
|