Rapid-Tech Equipment Logo Combo Kit Power Quality Recorder Power Quality Analyzer Multifunction Digital Multimeter

Nationwide - Call 1800 358 531 

Amprobe logo

GP-2 GEOTEST Ground Resistance and Resistivity Tester

 
Benefits
  • Three point test (fall of potential) measures earth ground resistance as required by equipment manufacturer specifications and as mandated by national code requirements for proper grounding.
  • Two point test is used to test grounding wires resistance and resistance of connection points between ground system elements i.e. wires and electrodes.
  • Tests soil for a new ground system design.
  • Does not require any additional meters to test voltage before grounding test is performed.
  • Easy to operate.
  • Data can be stored for later viewing.
  • Downloads data to a personal computer to generate reports and store historical data.

GP-2 GEOTEST Ground Resistance and Resistivity Tester

Features
  • Measure Earth Ground Resistance (Ω).
  • Automatically Calculate Resistivity (mΩ).
  • Test leads, auxiliary electrodes and software are included for a complete instrument.
  • Voltage measurement.
  • Automatically applies three testing frequencies for the most accurate readings.
  • Auto ranging.
  • Stores up to 999 measurements in the memory.
  • DATA download to a PC (via RS-232).
 

Specifications (23°C ±5°C, <80% R.H.)

 

Resistance Measurement:

Range (*)

Resolution Accuracy(**)

0.01Ω to 19.99Ω

0.01Ω ±(2% of Rdg + 3 digits)

20.0Ω to 199.9Ω

0.1Ω ±(2% of Rdg + 3 digits)

200Ω to 1999Ω

1Ω ±(2% of Rdg + 3 digits)
 

Resistivity Measurement p

Range (*)

Resolution Accuracy(**)

0.6Ωm to 125.6Ωm

0.1Ωm ±(2% of Rdg + 3 digits)

0.125Ωm to 1.256kΩm

0.001kΩm ±(2% of Rdg + 3 digits)

1.25kΩm to 19.99kΩm

0.01kΩm ±(2% of Rdg + 3 digits)

20.0kΩm to 199.9kΩm

0.1kΩm ±(2% of Rdg + 3 digits)
 

(*) Automatic selection of the range

(**) If Rp > 100RE and/or Rc > 100RE, Rp > 50kΩ and/or RC > 50kΩ, if the instrument carries out the test the accuracy of the instrument is ±(10% of reading).

 

Rp = resistance of the voltage circuit.
Rc = resistance of the current circuit.
RE = earth resistance
p = 2ΠDRE = calculated resistivity

 

Testing Frequency

125Hz, 75Hz, 41.66Hz

Test Current

10mA

Open-terminal Measuring Voltage

25Vrms

Waveform of Measuring Voltage

Sine-wave

 

Interfering Voltage:

Amperometric circuit: The measurement is taken with the stated accuracy if the interfering voltage is ≤ 3V, while for interfering voltages between 3V and 30V inclusive, the accuracy decreases progressively; with an interfering voltage of about 30V the instrument does not perform the test.

 

Voltmetric circuit: The measurement is taken if the interfering voltage is ≤ 3; in case of higher voltages the instrument does not perform the test.

 
 

Range

Resolution Accuracy(**)

500V

1V ±(2% of Rdg + 2 digits)
 

General Specifications

 

Display

65mm x 65mm LCD

Memory

999 memory locations

Interfaces

Opto-insulated serial output RS-232 (to transfer data to a PC)

Operating Temperature

-10°C to 50°C, <80% R.H.

Storage Temperature

-20°C to 60°C, <70% R.H.

Safety

EN 61010, EN 61557-1, EN 61557-5 standards

Insulation

Class 2, double insulation

Pollution

2

Surge Voltage Category

CAT III 250V (phase to earth)

 

 

Power Supply

Six 1.5V size 'AA' batteries (LR6, AM3, MN 1500)

Battery Life

300 measurements approx.

Auto Power Off

Yes

Low Battery Indication

Yes

 

 

Dimensions

8.74" (L) x 6.38" (W) x 2.25" (D)

Weight

1000gms (2.2 lb)

 

 

Included Accessories

Four each Earth Rods and cables with banana/crocodile clips, Carrying case, Optical serial cable and operators manual.

 


Fluke | Hart | Reed | Yokogawa | EuroSMC | Kyoritsu | Megger | | Tenmars | Tektronix | Amprobe | CIE | Silvertronic |
 Site Map | Search | About Us | Contact Us

 

Rapid-Tech Equipment
ABN 79 883 184 102
1300 Ferntree Gully Road. Scoresby. Victoria 3179
P.O. Box 4243 Knox City Centre. Victoria 3152

Phone: +61 3 9763 3299     Fax: +61 3 9753 2132