Specifications (23°C
±5°C, <80% R.H.) |
|
|
|
Resistance Measurement: |
|
Range (*) |
Resolution |
Accuracy(**) |
|
0.01Ω to
19.99Ω |
0.01Ω |
±(2% of Rdg + 3 digits) |
|
20.0Ω to
199.9Ω |
0.1Ω |
±(2% of Rdg + 3 digits) |
|
200Ω to 1999Ω |
1Ω |
±(2% of Rdg + 3 digits) |
|
| |
|
Resistivity Measurement p |
|
Range (*) |
Resolution |
Accuracy(**) |
|
0.6Ωm to
125.6Ωm |
0.1Ωm |
±(2% of Rdg + 3 digits) |
|
0.125Ωm to
1.256kΩm |
0.001kΩm |
±(2% of Rdg + 3 digits) |
|
1.25kΩm to
19.99kΩm |
0.01kΩm |
±(2% of Rdg + 3 digits) |
|
20.0kΩm to
199.9kΩm |
0.1kΩm |
±(2% of Rdg + 3 digits) |
|
| |
|
(*) Automatic selection of the range |
|
(**) If Rp > 100RE
and/or Rc > 100RE, Rp > 50kΩ
and/or RC > 50kΩ, if the instrument carries out the test
the accuracy of the instrument is ±(10% of reading). |
|
|
Rp = resistance of the
voltage circuit.
Rc = resistance of the current circuit.
RE = earth resistance
p = 2ΠDRE
= calculated resistivity |
|
| |
|
Testing Frequency |
125Hz, 75Hz, 41.66Hz |
|
Test Current |
10mA |
|
Open-terminal Measuring Voltage |
25Vrms |
|
Waveform of Measuring Voltage |
Sine-wave |
|
| |
|
Interfering Voltage: |
|
Amperometric circuit: The
measurement is taken with the stated accuracy if the interfering
voltage is ≤ 3V, while for interfering voltages
between 3V and 30V inclusive, the accuracy decreases progressively;
with an interfering voltage of about 30V the instrument does not
perform the test. |
|
|
|
Voltmetric circuit: The
measurement is taken if the interfering voltage is
≤ 3; in case of higher voltages the instrument
does not perform the test. |
| |
| |
|
Range |
Resolution |
Accuracy(**) |
|
500V |
1V |
±(2% of Rdg + 2 digits) |
|
| |
|
General Specifications |
|
|
|
Display |
65mm x 65mm LCD |
|
Memory |
999 memory locations |
|
Interfaces |
Opto-insulated serial output
RS-232 (to transfer data to a PC) |
|
Operating Temperature |
-10°C to
50°C, <80% R.H. |
|
Storage Temperature |
-20°C to
60°C, <70% R.H. |
|
Safety |
EN 61010, EN 61557-1, EN 61557-5
standards |
|
Insulation |
Class 2, double insulation |
|
Pollution |
2 |
|
Surge Voltage Category |
CAT III 250V (phase to earth) |
|
|
|
|
Power Supply |
Six 1.5V size 'AA' batteries (LR6,
AM3, MN 1500) |
|
Battery Life |
300 measurements approx. |
|
Auto Power Off |
Yes |
|
Low Battery Indication |
Yes |
|
|
|
|
Dimensions |
8.74" (L) x 6.38" (W) x 2.25" (D) |
|
Weight |
1000gms (2.2 lb) |
|
|
|
| |
|
Included Accessories
|
|
Four each Earth Rods and cables with
banana/crocodile clips, Carrying case, Optical serial cable and
operators manual. |