TMD90A Dual Input Digital Thermometer

 

Description
The TMD90A is a dual input thermometer that accepts type
K, J, T, R, S, and E thermocouples and is ideal for HVAC/R technicians, electricians, research, industrial process, and quality control. The dual inputs allow easy super-heat and sub-cool temperature measurement as well as cut-out and in temperature measurements. The triple display with backlight shows T1, T2, and T1 - T2 and includes Hold, Min/Max, Relative, and Timer / Date Stamp function

The TMD90A supports dual channel real time data acquisition using the built-in RS-232 interface and optional software and data transfer cable (Model TM-SWA).

 

TMD90A Dual Input Digital Thermometer

 

 

 

 

 

 

Safety Conformity

Features
  • High accuracy, multiple type input thermometer.
  • Displays T1, T2, and T1-T2 simultaneously.
  • Accepts six different thermocouple types K, J, T, R, S E.
  • Outputs real time measurement data with time stamp and Min/Max indicators.
  • Measures from -328°F / -200°C to 3200°F / 1760°C.
  • Supplied with Deluxe carrying case and two Type K probes.
  • RS232 output with optional cable and software, TM-SW.
Temperature Ranges

Thermocouple Type

Range

 Type K -200°C to 1370°C   -328°F to 2498°F  
 Type J -200°C to 760°C   -328°F to 1400°F  
 Type T -200°C to 390°C   -328°F to 730°F  
 Type R and S 0°C to 1760°C   -32°F to 3200°F  
 Type E -200°C to 736°C   -328°F to 1832°F  
 

Temperature Accuracy °C

T/C Type Range Resolution Accuracy
Type K -200°C to 650°C 0.1° 0.1% of Rdg +0.7°C
651°C to 1370°C 1.0° 0.1% of Rdg +0.7°C
Type J -200°C to 500°C 0.1° 0.1% of Rdg +0.7°C
501°C to 760°C 1.0° 0.1% of Rdg +0.7°C
Type T -200°C to 390°C 0.1° 0.1% of Rdg +0.7°C
Type R 0°C to 1000°C 0.1° 0.3% of Rdg +0.7°C
1001°C to 1760°C 1.0° 0.3% of Rdg +0.7°C
Type S 0°C to 1000°C 0.1° 0.3% of Rdg +0.7°C
1001°C to 1760°C 1.0° 0.3% of Rdg +0.7°C
Type E -200°C to 380°C 0.1° 0.3% of Rdg +0.7°C
-381°C to 736°C 1.0° 0.3% of Rdg +0.7°C
 

Temperature Accuracy °F

T/C Type Range Resolution Accuracy
Type K -328°F to 1000°F 0.1° 0.1% of Rdg +1.4°F
1001°F to 2498°C 1.0° 0.1% of Rdg +1.4°F
Type J -328°F to 940°F 0.1° 0.1% of Rdg +1.4°F
941°F to 1400°F 1.0° 0.1% of Rdg +1.4°F
Type T -328°F to 730°F 0.1° 0.1% of Rdg +1.4°F
Type R 32°F to 1000°F 0.1° 0.1% of Rdg +1.4°F
1001°F to 3200°F 1.0° 0.1% of Rdg +1.4°F
Type S 32°F to 1000°F 0.1° 0.1% of Rdg +1.4°F
1001°F to 3200°F 1.0° 0.1% of Rdg +1.4°F
Type E -328°F to 720°F 0.1° 0.1% of Rdg +1.4°F
721°F to 1832°F 1.0° 0.1% of Rdg +1.4°F
 

General Specifications

Operating Temperature

0 °C to 50 °C (32 °F to 122 °F) at 0 to 85 % R.H. (non-condensing)

Ambient Coefficient

 

0 °C to 18 °C and 28 °F to 50 °C (ambient temperatures) for each °C ambient below     18 °C or above 28 °C, add the following tolerance into the accuracy spec:                 0.01 % of reading +0.03 °C (0.01 % of reading +0.06 °F)
 

Included Accessories

Complete with two K-type bead probes, Hard carrying case, batteries and users manual.

 


Fluke | Hart | Reed | Yokogawa | EuroSMC | Kyoritsu | Megger | | Tenmars | Tektronix | Amprobe | CIE | Silvertronic |
 Site Map | Search | About Us | Contact Us

 

Rapid-Tech Equipment
ABN 79 883 184 102
1300 Ferntree Gully Road. Scoresby. Victoria 3179
P.O. Box 4243 Knox City Centre. Victoria 3152

Phone: +61 3 9763 3299     Fax: +61 3 9753 2132