Logo of Rapid-Tech EquipmentRapid-Tech Equipment, Australia's leading supplier of quality test equipment.

Home Up Multimeters Current Clamps Automotive Meters Thermometers


shop_ani.gif (19897 bytes)

cie_logo.gif (2131 bytes)

CIE 2606 1000 Amp AC/DC
True RMS Digital Current Clamp/Multimeter

    • 3¾ digit, 3999 counts, Bar Graph display

    • DC volts (Auto) 0-400mV/4/40/400/1000V ±0.5%

    • AC volts (Auto) (True RMS)
      0-400mV/4/40/400/750V   ±1.5%

    • DC current 0 - 200A/1000A   ±1.5%

    • AC current (True RMS) 0-200A / 1000A ±1.5%

    • Resistance (Auto)
       0-400
      W/4kW/40kW/400kW/4MW/40MW ±1.0%

    • Capacitance (Auto) 0-4nF/40nF/400nF/4µF/40µF ±1.5%

    • Frequency (Auto) 
      0-100Hz/1kHz/10kHz/100kHz/400kHz ±0.5%

    • Resolution 100mV, 100mA, 0.1W, 1pF, 0.01Hz

    • Diode Test

    • Continuity test

    • Data Hold

    • Max/Min Hold

    • Peak Hold

    • (Zero) Relative

    • Auto Power Off

    • Jaw opening capability
                                    57mm Conductor
                                    70mm x 18mm bus bar

    • Safety Test Leads

    • Safety Input Jacks

    • Overload Protection on all Ranges

    • Safety IEC 1010-1,IEC 1010-2-032
                                      UL, CE Approved  

    Download Data Sheet (PDF 130.3kBytes)

     


CIE 2608  2000 DCA/1500 ACA True RMS
Digital Current Clamp/Multimeter

  • 3¾ digit, 3999 counts, Bar Graph display

  • DC volts (Auto) 0 -400mV/4/40/400/1000V ±0.5%

  • AC volts (Auto) (True RMS) 0 -400mV/4/40/400/750V   ±1.5%

  • DC current 0 - 200A/2000A   ±1.5%

  • AC current (True RMS) 0-200A / 1500A ±1.5%

  • Resistance (Auto)
      0 -400
    W/4kW/40kW/400kW/4MW/40MW ±1.0%

  • Capacitance (Auto) 0 -4nF/40nF/400nF/4µF/40µF ±1.5%

  • Frequency (Auto) 
    0-100Hz/1kHz/10kHz/100kHz/400kHz ±0.5%

  • Resolution 100mV, 100mA, 0.1W, 1pF, 0.0 1Hz

  • Diode Test

  • Continuity test

  • Data Hold

  • Max/Min Hold

  • Peak Hold

  • (Zero) Relative

  • Auto Power Off

  • Jaw opening capability
                                  57mm Conductor
                                  70mm x 18mm bus bar

  • Safety Test Leads

  • Safety Input Jacks

  • Overload Protection on all Ranges

  • Safety IEC 1010-1,IEC 1010-2-032
                                    UL, CE Approved.

Download Data Sheet (PDF 44.9kBytes)

 

CIE CA60 60 Amp AC/DC Current Clamp
for use with a Multimeter

  •  

    • Uses two Hall-Effect sensors

    • For use with any multimeter with 200mV or/and 2V  ranges for direct readout.
      (with an input impedance of at least 1M
      W)

    • An LED lights up when the clamp meter is under power.

    • Zero adjustment knob to compensate the hysteresis effect in DC measurements.

    • Transformer ratio 10:1, 100:1

    • Output 1mV/10mA, 1mV/100mA

    • Current Range 0 to 60Amps 

    • Accuracy DC Amps ±1.5%
                        AC Amps±2% (40Hz-2kHz)
                        AC Amps±4%(2kHz-10kHz)
                        AC Amps±6%(10kHz-20kHz)

    • Jaw opening capability
                                    9mm Conductor

    • Safety Designed to meet                                 IEC 1010-1, IEC 1010-2-032 CE

d

Download Data Sheet (PDF26.9kBytes)


 

CIE CA600 600 Amp AC/DC Current Clamp
for use with a Multimeter

  • Uses two Hall-Effect sensors

  • For use with any multimeter with 200mV or/and 2V  ranges for direct readout.
    (with an input impedance of at least 1M
    W)

  • An LED lights up when the clamp meter is under power.

  • Zero adjustment knob to compensate the hysteresis effect in DC measurements.

  • Transformer ratio 1000:1

  • Output 1mV/Amp

  • Current Range 0 to 600Amps 

  • Accuracy DC Amps ±2%+2A
                      AC Amps±3% +2A
                     (50Hz-400Hz)
                      

  • Jaw opening capability
                                  30mm Conductor

  • Safety Designed to meet IEC 1010-1,
    IEC 1010-2-032 CE Approved

CIE 1000D 1000 AMP AC/DC Current Clamp
 for use with a Multimeter

    • Uses two Hall-Effect sensors

    • For use with any multimeter with 200mV or/and 2V  ranges for direct readout.
       (with an input impedance of at least 1M
      W)

    • An LED lights up when the clamp meter is under power.

    • Zero adjustment knob to compensate the hysteresis effect in DC measurements.

    • Transformer ratio 1000:1

    • Output 1mV/Amp

    • Current Range 0 to 1000Amps 

    • Accuracy DC Amps ±1.5%
                        AC Amps±1.5%+2 Amps
                        (50-60Hz)
                        AC Amps±3%+2 Amps
                       (60-400Hz)

    • Jaw opening capability
                                    57mm Conductor
                                    70mm x 18mm bus bar

    • Safety Designed to meet IEC 1010-1,
      IEC 1010-2-032 CE


 

Model CA-1000A AC Current Clamp
 for use with a Multimeter

  • For use with any multimeter with 200mV
     or/and 2V  ranges for direct readout.
     (with an input impedance of at least 1M
    W)

  • Transformer ratio 1000:1

  • Output 1mV/Amp

  • Current Range 0 to 1000Amps RMS

  • Accuracy ±1.5% + 2 Amps (50-60Hz)
                      ±3% + 2 Amps    (60-400Hz)

  • Jaw opening capability
                                  57mm Conductor
                                  70mm x 18mm bus bar

  • Safety Designed to meet                                
    IEC 1010-1, IEC 1010-2-032 CE

 

For additional information, or to order, call Rapid-Tech today

Telephone

+61 3 9887 3777

Facsimile

+61 3 9800 3014

e-mail

rapid.tech@pobox.com