Model 16 multimeter
With Thermometer
Its a thermometer
The Fluke 16 measures temperature quickly and accurately. Standard
equipment includes an 80PK-1 bead probe thermocouple and an 80AK temperature adaptor,
which is compatible with a wide range of type K thermocouples with mini-connectors.
Its a flame rod circuit tester
A microamp function is included for flame sensor measurements down to
0.1 microamps.
Its a multimeter with capacitance
Use the Fluke test motor start and run capacitors up to 10,000
microfarads. Rely on the Fluke 16 to make your everyday measurements - up to 600 volts ac
or dc, 40 megohms, diode test and exceptionally fast continuity.
Accurate temperature measurement from -40° C to 400° C
Confidently test flame sensor circuits with microamp measurement down to 0.1
microamps
Capacitance up to 10,000 microfarads
Min/Max recording with relative time stamp records the highest and lowest voltage
readings during a 100-hour period
Auto-ranging
High resistance ranges to 40 Megohm
Millivolt range for compatibility with other accessories
V-Check mode is designed for safety. When measuring ohms, continuity, or
diode test modes, the meter automatically switches to measuring ac or dc volts if more
than 4.5V is present
Continuity Capture locates intermittent opens as brief as
250 microseconds and identifies them in a symbolic display as short-to-open or
open-to-short
Sleep mode preserves battery life
4000 count digital display
Meter includes: 80PK-1 Bead Temperature Probe, 80AK Temperature Adaptor, TL75 Test
Leads, and C10 Holster
Safety
- 600V ac/dc, maximum voltage between any terminal and earth ground.
- Conforms to the requirements of IEC-1010-1, 1990-09 and
ANSI/ISA-S82.01-94 for use in Overvoltage Category III locations.
- Make ac or dc voltage measurements on electrical distribution systems to
600V where transients do not exceed 6 kV and only on circuits limited to 14 kVA if the
circuit voltage rating is above 250V.
Certification agencies (approvals/listings pending):
- UL Per standard UL 3111
- CSA Per standard CSA/CAN C22.2 No.1010.1-92
- TÜV Per standard EN61010 Part 1-1993
Drop test ANSI/ISA-S82.01-94 and EN61010 Part1-1993. 10 ft. drop to
hardwood on concrete
Size (HxWxL) 2.8 cm x 7.5 cm x 16.6 cm
Battery life 650 hours with Alkaline
Weight 340g
Function
|
Range
|
Resolution
|
Accuracy
|
DC Volts
|
4000 mV *
4.000 V
40.00 V
400.0 V
600. V |
1 mV
0.001 V
0.01 V
0.1 V
1 V |
0.9%+2
0.9%+2
0.9%+1
0.9%+1
0.9%+1 |
AC Volts
|
4000 mV*
4.000 V
40.00 V
400.0 V
600 V |
1 mV
0.001 V
0.01 V
0.1 V
1 V |
1.9%+3
1.9%+3
1.9%+3
1.9%+3
1.9%+3 |
Current AC/DC
|
200uA |
0.1uA |
0.5%+2 |
Ohms
|
400.0 Ohms
4.000 k Ohms
40.00 k Ohms
4.000 M Ohms
40.00 M Ohms |
0.1 Ohms
0.001 k Ohms
0.01 k Ohms
0.001 M Ohms
0.01 M Ohms |
0.9%+2
0.9%+1
0.9%+1
0.9%+1
0.9%+1 |
Capacitance
|
1.000 uF
10.00 uF
100.0 uF
1000 uF
10,000 uF |
0.001 uF
0.01 uF
00.1 uF
001 uF
0010 uF |
1.9%+2**
1.9%+2**
1.9%+2**
1.9%+2**
10%+90 typical** |
Temperature
|
15 to 750° F
-40 to -15° F
-10 to 400° C
-40 to -10° C |
0.1° F
0.1° F
0.1° C
0.1° C |
1%+1.5° F typical***
1%+2.7° F***
1%+.8° C typical***
1%+1.5° C *** |
* The 4000 mV range can only be entered in manual
range mode. Use the 4000 mV range with accessories
**The accuracy specification is for capacitors that have negligible dielectric absorption.
Capacitance measured with rc charge technique that evaluates C=Q/V. Capacitors with
non-negligible dielectric absorption can be measured, but measurement values may be in
error.
***The accuracy specifications for temperature do not include the error caused by the
thermocouple.
For additional information or to order, call Rapid-Tech