Features
- Two 5000 count true RMS digital multimeters.
- A dual-input TrentPlotTM recorder.
- Connect-and-ViewTM trigger simplicity for
hands-off operation.
- Industrial Network Bus Health mode.
- Power Measurements for single phase and balanced 3-phase
systems.
- Harmonics mode, up to 33rd harmonic (24th in 400Hz).
- High resolution, low impedance measurements.
- Reading of Hz and Rotations Per Minute (RPM) for use
with electrical and combustion engines.
- Measurement of Vpwm for use on motor drive outputs.
- ‘Save and recall’ using a user-defined name.
- Fluke i400s Current Clamp included as a standard.
ScopeMeter® Performance
Features |
|
Key Benefits
-
Bus Health mode
Industrial Buses (so called ‘Field Buses’) link the
machinery on the factory floor to each other, to sensors,
actuators and to a central computer and control system. The
Fluke 125 now offers extensive capabilities to test the
proper functioning of the network by analyzing the
electrical signals on the network (see screen copy).
-
Supported Field bus types are:
|
| |
- AS-i bus
- CAN-bus
- Interbus
- ControlNet
- MOD-Bus
- Foundation Fieldbus
- Capacity to define two ‘user defined’
network type.
- Profibus
- Ethernet (coax and TP, 10 Mb/s)
- RS-232
- RS-485
|
Note: the Bus Health function is not
a protocol analyzer but is a tool to investigate
the electrical layer of the communications system, giving
‘good’ or ‘no good’ indicators for individual parameters of
the electrical system.
|

Example of Bus Health screen
|
|
| |
- Watts
- VA
- VAR
- Power Factor (PF)
- High resolution, low impedance measurements
|
|
|
- Harmonics mode, up to 33rd harmonic
(see screen copy). This mode supports a wide range
of fundamental mains frequencies including 16.?, 50, 60
and 400 Hz systems!
- High resolution, low impedance measurements
50.00 W full scale, for use on motor windings and
other low resistance wiring.
- Reading of Hz and Rotations Per Minute (RPM) for
use with electrical and combustion engines.
Input signal can be:
| |
- 2 rotations per 1 pulse.
- 1 rotation per 1 pulse.
- 1 rotation per 2 pulses.
- 1 rotation per 4 pulses
|
|

Example of Harmonics mode screen |
| |
|
- Measurement of Vpwm for use on motor drive
outputs
as was implemented on the 190-series before
‘Save and recall’ using a user-defined name
for the stored data set. Each data set (up 9 pieces)
contains screen + set-up + data. Names can be created
freely and altered at a later stage.
- Fluke i400s Current Clamp included as a standard
with Fluke 125. Furthermore, the i5s current clamp
is supported by the 125 firmware. Note: The full level
of functionality of the Fluke 124 is included in the
125. And also all accessories found with the 124 are
included.
- New edition of FlukeView ScopeMeter SW90W V4.4
The functionality level in conjunction with the
120-series is no different from V4.3 and V4.2
- Shipments of the Fluke-125/S and of the SCC120 will
include the V4.4 per the release of the Fluke-125. For
customers who have release V4.x, a free update will be
available through the Fluke public website.
|

|
|
|
|
|