Technical Specifications |
|
Test Voltage 250 Volts DC
|
|
Range: |
200KΩ to
5GΩ |
|
Accuracy: |
5% |
|
Range: |
5GΩ to 50GΩ |
|
Accuracy |
20% |
|
|
Test Voltage 500 Volts DC
|
|
Range: |
200KΩ to
10GΩ |
|
Accuracy: |
5% |
|
Range: |
10GΩ to
100GΩ |
|
Accuracy |
20% |
|
|
Test Voltage 1000 Volts DC
|
|
Range: |
200KΩ to
20GΩ |
|
Accuracy: |
5% |
|
Range: |
20GΩ to
200GΩ |
|
Accuracy |
20% |
|
|
Test Voltage 2500 Volts DC
|
|
Range: |
200KΩ to
50GΩ |
|
Accuracy: |
5% |
|
Range: |
50GΩ to
500GΩ |
|
Accuracy |
20% |
|
|
Test Voltage 5000 Volts DC
|
|
Range: |
200KΩ to
100GΩ |
|
Accuracy: |
5% |
|
Range: |
100GΩ to 1
TΩ |
|
Accuracy |
20% |
|
|
Short Circuit Current |
> 1mA and < 2mA |
|
Bar Graph |
|
|
Insulation Test Voltage |
|
Accuracy: |
0% to 10% at 1mA load current |
|
|
Induced AC Mains Current Rejection |
|
|
Charging Rate for Capacitive Load |
5 s/µF |
|
Leakage Current
|
|
Range: |
1nA to 2mA |
|
Accuracy: |
±(5%
+ 2nA) |
|
|
Capacitance Measurements
|
|
Range: |
0.01µF
to 15.00µF |
|
Accuracy: |
±(15%
of reading + 0.03µF) |
|
|
Live Circuit Indicator
|
|
Range: |
30V to 600V (AC/DC, 50/60Hz) |
|
Accuracy: |
±(5%
+ 2V) |
|
|
|
|
Settable: |
1 minute increments |
|
Indication: |
1 second resolution |
|
|
Ramp
|
0% to 100% of selected test voltage,
or until breakdown. |