Model 1577 and 1587 Insulation Tester Multimeter - Specifications

 
Specifications
Voltage DC

Maximum Voltage:

1000V

Accuracy 1577:

±(0.2%+2)

Accuracy 1587:

±(0.09%+2)

Accuracy 1587T: ±(0.09%+2)

Maximum Resolution:

0.001V

Voltage AC (True-rms)
Maximum Voltage: 1000V
Accuracy 1577: ±(2%+3)
Accuracy 1587: ±(2%+3)
Accuracy 1587T: ±(2%+3)
AC Bandwidth 1587: 5kHz*
Note* with low pass filter: 3db @ 800Hz
Maximum Resolution: 0.1mV
Current DC
Maximum Current: 400mA
Accuracy 1577: ±(1.0%+2)
Accuracy 1587: ±(0.2%+2)
Accuracy 1587T: ±(0.2%+2)
Maximum Resolution: 0.01mA
Current AC (True-rms)
Maximum Current: 400mA
Accuracy 1577: ±(2.0%+2)*
Accuracy 1587: ±(1.5%+2)*
Accuracy 1587T: ±(1.5%+2)*
Note* 1kHz bandwidth  
Maximum Resolution: 0.01mA
Resistance
Maximum Resistance: 50MΩ
Accuracy 1577: ±(1.2%+2)
Accuracy 1587: ±(0.9%+2)
Accuracy 1587T: ±(0.9%+2)
Maximum Resolution: 0.1Ω
Capacitance 1587/1587T only
Maximum Capacitance: 9.9999µF
Accuracy: ±(1.2%+2)
Maximum Resolution: 1nF
Frequency 1587/1587T only
Maximum Frequency: 100kHz
Accuracy: ±(0.1%+1)
Maximum Resolution: 0.01Hz
Temperature Measurement 1587/1587T only
Temperature: -40°C to 537°C
(excluding probe) -40°F to 998°F
Diode Test 1587/1587T only
Range: 6V
Accuracy: ±(2%+1)
Resolution: 1mV
 
 

Insulation Test

Measurement

1577

Range

1587

 

1587T

0.1M to 600M

0.1M to 2G

0.1M to 100M

Test Voltages

1577

 

1587

 

1587T

500V, 1000V

50V, 100V, 250V, 500V, 1000V

50V, 100V

Test Voltage

1577

Accuracy

1587

 

1587T

+20% -0%

+20% -0%

+20% -0%

Insulation Test

1577

Current

1587

 

1587T

1mA nominal

1mA nominal

1mA nominal

Auto Discharge

1577

 

1587

 

1587T

Discharge time <0.5sec for C=1µF or less

Discharge time <0.5sec for C=1µ or less

Discharge time <0.5sec for C=1µF or less

Maximum

1577

Capacitance Load

1587

 

1587T

Up to 1µF load

Up to 1µF load

Up to 1µF load

 

 

Environmental Specifications

Operating Temperature

-20°C to +55°C

Storage Temperature

-40°C to +60°C

Humidity
(without Condensation)

0% to 95%

10°C to +30°C

0% to 75%

30°C to +40°C

0% to 40%

40°C to +55°C

Operating Altitude

2000 meters

 

 

Safety Standards

Overvoltage Category

 

Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000V and CAT IV 600V.

Agency Approvals
 

2000 m CAT III 1000V, CAT IV 600V
3000 m CAT II 1000V, CAT III 600V

 

 

General Specifications

Size

203mm x 100mm x 50mm (with holster)

Weight

624g

Warranty

3 years

Battery Life  (Alkaline)

      

 

 

 

Meter use:

1000 hours

Insulation

Meter can perform at least 1000 insulation tests

Test use:

with fresh alkaline batteries at room temperature.

 

These are standard tests of 1000V into 1MΩ with

 

a duty cycle of 5 seconds on and 25 seconds off.

IP Rating

IP40

 

 