1740 Series 3-Phase Power Quality
Logger - Specifications |
|
|
|
|
General Specifications |
|
Intrinsic Error |
Refers to the reference conditions and is guaranteed
for two years. |
|
Warranty |
Two years |
|
Recalibration Interval |
Two years recommended |
|
Quality System
|
Developed, designed, and manufactured according to
DIN ISO 9001. |
|
Reference Conditions
|
| |
23°C
2K; 74°F ±2K, Vm=230V ±10%,
50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz |
|
Phase Sequence: |
L1, L2, L3 |
|
Interval length: |
10 minutes |
|
Wye connection: |
(l1, L2, L3 to N) |
|
Power supply: |
88 volts to 265 volts AC |
|
|
|
|
Environmental Condition Ranges |
|
Working Temperature |
-10°C to 55°C;
14°F to 131°F |
|
Operating Temperature |
0°C to 35°C;
32°F to 95°F |
|
Storage Temperature |
-20°C to 60°C;
-4°F to 140°F |
|
Reference Temperature |
23°C ±2K; 74°F
±2K |
|
Relative Humidity |
Class C2 acc. IEC 60654-1 (Model 1743) |
|
Class C2 acc. IEC 60654-1 (Model 1744) |
|
Class B2 acc. IEC 60654-1 (Model 1745) |
|
Housing |
Robust, fully insulated housing and accessories |
|
Protection Type |
IP65 as per EN 60529 (Model 1743) |
|
IP65 as per EN 60529 (Model 1744) |
|
IP50 as per EN 60529 (Model 1745) |
|
Safety
|
IEC/EN 61010-1 600V CAT III, 300V CAT IV,
pollution degree 2, double insulated |
|
Type Test Voltage |
5.2 kV rms, 50 Hz/60Hz, 5 sec |
|
EMC
|
|
Emission: |
IEC/EN 61326-1, EN 55022 |
|
Immunity: |
IEC/EN 61326-1 |
|
|
|
|
|
|
|
Voltage and Current Measurements |
|
Input Voltage |
|
|
Input range VIP-N: |
maximum 480 V AC |
|
Input range VIP-P: |
maximum 830 V AC |
|
Max. overload voltage: |
1.2 VI |
|
Input range selection: |
by job programming |
|
Connections: |
P-P or P-N, 1- or 3-phase |
|
Nominal voltage VN: |
less than or equal to 999 kV
with PTs and ratio |
|
Input resistance:
|
approx. 820 KΩ
per channel Lx-N single-phase (L1 or A, L2 or B, L3 or C
connected) approx. 300 KΩ |
|
Intrinsic uncertainty: |
0.1% of VI |
|
Voltage transformer: |
ratio: <999 kV/V |
|
Ration selection: |
by job programming |
|
|
Current Input with Flexi Set |
|
|
Input ranges II
L1 or A, L2 or B, L3 or CN: |
15A /150A / 1500A / 3000A AC
|
|
Measuring Range: |
0.75A to 3000A AC |
|
Intrinsic uncertainty: |
<2% of II |
|
Position influence:
|
maximum ±2% of measured
value - for distance conductor to measurement head >30mm |
|
Stray field influence:
|
< ±2A AC for Iext=500A AC
and distance to measuring head >200mm |
|
Temperature coefficient: |
<0.05%/k |
|
Current transformer: |
ratio less than or equal to
999 kA/II |
|
Ratio selection: |
by job programming |
|
Connection:
|
3-phase, 3-phase +N, 2-phase
L1 or A and L3 or C (2 Wire-meter-method) 7 pole
connector |
|
|
Current Input for Clamp |
|
|
Input ranges II
L1 or A,
L2 or B, L3 or C, N: |
0.5V nominal (for II)
1.4V peak
|
|
Intrinsic uncertainty: |
<3% of II |
|
Maximum overload: |
10V AC |
|
Input resistance: |
Approx. 8.2KΩ |
|
Current transformer: |
ratioΩ
999kA/II |
|
|
Power Systems |
Delta, 2-Element Delta, Wye,
Single-Phase, Split Single-Phase |
|
| |
| |
|
Mechanical and General Specifications |
|
Power
Supply Functional range: |
| |
|
Power consumption: |
|
Ride through model 1743: |
|
Ride through model 1744: |
|
Ride Through model 1745: |
|
Fuse:
|
|
|
88V to 660V absolute,
50Hz/60Hz |
|
100V to 350V DC internal fuse 630mA T |
|
5 watts |
|
3 second capacitor |
|
3 second capacitor |
|
Internal battery for typical
> 5 hours ride through with intelligent power management |
|
Power supply fuse can be
replaced in service facility only.
Supply can be connected in parallel to measuring inputs
(up to 660V) |
|
|
Display Indicators
|
LED's for status and voltage
levels
Fluke model 1745: LC-display with backlight for voltage,
current, active power, phase sequence |
|
Memory |
|
Intervals:
|
|
Events: |
|
Memory model: |
|
|
Capacity 8 MB Flash-EPROM |
|
A function >12000 intervals
for >85 days with 10 minute intervals.
P function >30000 intervals for >212 days with 10 minute
intervals. |
|
>13000 |
|
linear, circular |
|
|
Interface
|
RS232, 9600 ...115000 baud,
automatic baud rate selection, 3-wire communication |
|
Measurement |
|
A/D converter: |
|
Anti-aliasing filter: |
|
Frequency response: |
|
Interval length: |
|
Averaging time for
Min/Max values: |
|
Time base |
|
Resolution: |
|
Deviation: |
|
| |
|
16 bit, sample rate: 10.24
kHz |
|
FIR-Filter, fc=4.9
kHz |
|
uncertainty <1 % of Vm for
40 Hz to 2500 Hz |
|
1, 3, 5, 10, 30s, 1, 5,10,
15, 60 minutes |
|
1/2, 1 mains period, 200 ms,
1, 3, 5 seconds
|
|
|
|
10ms (at 50Hz) |
|
2s/day at 23°C
(74°F) ±2K |
|
|
Dimensions |
|
Model 1743:
|
|
Model 1744:
|
|
Model 1745:
|
|
| |
|
170mm (H) x 125mm (W) x 55mm
(D)
69" (H) x 51" (W) x 22" (D) |
|
170mm (H) x 125mm (W) x 55mm
(D)
69" (H) x 51" (W) x 22" (D) |
|
282mm (H) x 216mm (W) x 74mm
(D)
115" (H) x 88" (W) x 33" (D) |
|
|
Weight |
|
Model 1743: |
|
Model 1744: |
|
Model 1745 |
|
|
|
|
|
|