General
Specifications |
|
Display |
Color transmissive LCD 320 x
240 pixels (70mm diagonal) with two level backlight. |
|
Battery Power (qty 6) |
Battery. 1.5 volt Alkaline
AA MN 1500 or IEC LR6 |
|
Battery Life (typical) |
>10 hours (backlight on
full)
> 12 hours (backlight reduced) |
|
Battery Eliminator
(#BE345) |
Input: 110/230V 50/60 Hz
Output: 15V DC 300mA |
|
Dimensions
|
300mm (L) x 98mm (W) x 52mm
(D)
12" (L) x 3.75" (W) x 2" (D) |
|
Weight (including
batteries) |
820g (1.8 lb) |
|
Jaw Opening |
60mm |
|
Jaw Capacity |
58mm diameter |
|
Cleaning |
The unit can be cleaned with
an Isopropanol impregnated cloth. Do not use abrasives
or other solvents. |
|
| |
|
|
| Ambient Conditions
(for indoor use only) |
|
Reference Conditions |
All accuracies stated at 23°C
±1°C (73.4°F
±1.8°F) |
|
Operating Temperature |
0°C
to 50°C (32°F
to 122°F) |
|
Temperature Coefficient
of Current |
≤±0.15% of reading per
°C |
|
Temperature Coefficient
of Voltage |
≤±0.15% of reading per
°C |
|
Maximum Relative Humidity |
80% for temperatures up to
31°C (87°F)
decreasing linearly to 50% relative humidity at 40°C
(104°F) |
|
Maximum Operating
Altitude |
2000 m |
|
|
|
|
|
|
Electrical Safety |
|
Safety
|
IEC 61010-1 600V CAT. IV
double or reinforced insulation, Pollution Degree 2. |
|
Protection |
IP40; EN 60529 |
|
Maximum Safe Working
Voltages
|
|
Current Measurement: |
600V ACrms or DC
between uninsulated conductor and ground. |
|
Voltage Measurement: |
600V ACrms or DC
between either input terminal and ground, or 825V
between energised phase voltages (delta power
configuration). |
|
|
| |
|
|
|
E.M.C. |
|
Emission |
IEC/EN 61326-1: 1997 Class A |
|
Immunity |
IEC/EN 61326-1: 1997 Annex C
Performance Criterion B |
|
|
|
|
|
|
Electrical Data |
|
Accuracies
|
All accuracies stated at 23°C
±1°C (73.4°F
±1.8°F). See Ambient
condition specifications for temperature coefficients. |
|
| |
|
|
|
Current Measurement
(DC, DC rms, AC rms) |
|
Measuring Range |
0 to 2000 Amps DC or 1400
Amps AC rms |
|
Autorange Facility |
40A/400A/2000A |
|
Resolution
|
10mA in 40 Amp range
100mA in 400 Amp range
1 Amp in 2000 Amp range |
|
Accuracy |
| DC Current > 10A: |
±1.5% of reading ±5
digits |
| DC rms Current
<10A: |
±0.2 A |
| |
|
| AVG Current >10A: |
±3% of reading ±5
digits |
| Current <10A: |
±0.5 A |
| |
|
| Peak Current
>10A: |
±5% of reading ±5
digits |
| Current <10A: |
±0.5 A |
| |
|
| AHr Current >10A: |
±2% of reading ±5
digits |
| Current <10A: |
±0.5 AHr |
| |
|
|
Crest
Factor |
|
| 1.1 ≤ CF <3: |
±3% of reading ±5
digits |
| 3 ≤ CF <5: |
±5% of reading ±5
digits |
| Resolution: |
0.01 |
| |
|
|
Ripple |
|
| 2% ≤ RPL <100%: |
±3% of reading ±5
digits |
| 100% ≤ RPL <600%: |
±5% of reading ±5
digits |
| Resolution: |
0.1% |
| ldc > 5A, lac> 2A |
|
|
|
|
Note: |
All measurements DC and 15Hz to 1kHz |
| |
Maximum overload 10,000 A or rms x frequency <
400,000 |
| |
Amps rms is a true-rms measurement (AC + DC) |
|
| |
|
|
|
Voltage Measurement
(DC, DC rms, AC rms) |
|
Measuring Range |
0 to 825 Volts DC or AC rms |
|
Autorange Facility |
4V/40V/400V/750V |
|
Resolution |
|
1mV |
in 4 volt range |
|
10mV |
in 40 volt range |
|
100mV |
in 400 volt range |
|
1V |
in 750 volt range |
|
|
Accuracy |
|
DC and DC rms |
|
| Volt >1V: |
±1% of reading ±5
digits |
| Volt <1V: |
±0.02 V |
| |
|
| AVG Voltage >1V: |
±3% of reading ±5
digits |
| Voltage <1V: |
±0.03 V |
| |
|
| Peak Voltage
>1V: |
±5% of reading ±5
digits |
| Voltage <1V: |
±0.03 V |
| |
|
|
Crest Factor |
|
| 1.1 ≤ CF <3: |
±3% of reading ±5
digits |
| 3 ≤ CF <5: |
±5% of reading ±5
digits |
| Resolution: |
0.01 |
| |
|
|
Ripple |
|
| 2% ≤ RPL <100%: |
±3% of reading ±5
digits |
| 100% ≤ RPL <600%: |
±5% of reading ±5
digits |
| Resolution: |
0.1% |
| ldc > 5A, lac> 2A |
|
|
|
|
Note: |
All measurements DC and 15Hz
to 1kHz |
|
|
Maximum overload 10,000 A or
rms x frequency < 400,000 |
|
|
Amps rms is a true-rms
measurement (AC + DC) |
|
|
Harmonics |
|
Harmonics |
| Total Harmonic Distortion (THD) |
| 1% ≤THD <100%: |
±3% of reading ±5
digits |
| 100% ≤THD <600%: |
±5% of reading ±5
digits |
| Resolution: |
0.1% |
|
| Distortion Factor (DF) |
| 1% ≤DF <100%: |
±3% of reading ±5
digits |
| Resolution: |
0.1% |
| H02 ≤Vharm <H13: |
±5% ±2 digits |
| H13 ≤Vharm <H30: |
±10% ±2 digits |
|
|
| Note: |
All measurements up to 30th harmonic (40th harmonic
for 15Hz to 22Hz) |
| |
Frequency range of fundamental Fo 15Hz to
22 Hz and 45 Hz to 65 Hz Vacrms >1V |
|
|
|
|
Watts Measurement
(single- and three-phase) (DC, DC rms, AC rms) |
|
Measuring Range |
0 to 1650 kW DC or 1200 kW
AC |
|
Autoranging Facility |
4 kW, 40 kW, 400 kW, 1650 kW |
|
Resolution |
|
1 W |
in 4kW range |
|
10 W |
in 40 kW range |
|
100 W |
in 400 kW range |
|
1 kW |
in 1200 kW range |
|
|
Accuracy |
2.5% of reading ±5 digits
W (single phase) <2 kW ±0.08 kW
W (three phase) <4 kW ±0.25 kW |
|
| |
| |
| VA Measurement (single- and
three-phase) (DC, DC rms, AC rms) |
| Measuring Range |
0 to 1650 kVA DC or 1200 kVA AC |
| Autoranging Facility |
4 kVA, 40 kVA, 400 kVA, 1650 kVA |
| Resolution |
| 1 VA |
in 4 kVA range |
| 10 VA |
in 40 kVA range |
| 100 VA |
in 400 kVA range |
| 1 kVA |
in 1200 kVA range |
|
| Accuracy |
| VA >2 kVA: |
2.5% of reading ±5
digits |
| VA <2kVA: |
±0.08 kVA |
|
|
| |
| |
| VAR Measurement (single- and
three-phase) |
| Measuring Range |
0 to 1250 kVAR |
| Autoranging Facility |
4 kVAR, 40 kVAR, 400 kVAR, 1200 kVAR |
| Resolution |
| 1 VAR |
in 4 kVAR range |
| 10 VAR |
in 40 kVAR range |
| 100 VAR |
in 400 kVAR range |
| 1 kVAR |
in 1200 kVAR range |
|
| Accuracy |
| VAR >4 kVAR: |
2.5% of reading ±5
digits |
| VAR <4kVAR: |
±0.25 kVAR |
|
| Power Factor Range |
0.3 <PF <0.99 |
|
| |
| |
| Power Factor (single- and
three-phase) |
| Measuring Range |
0.3 capacitive to 1.0 and 1.0 to 0.3
inductive
(72.5° capacitive to 0°
and 0° to 72.5°
inductive) |
| Resolution |
0.001 |
| Accuracy |
±3° |
| Frequency Range |
15Hz to 1kHz |
|
| |
| |
| Displacement Power Factor (single-
and three-phase) |
| Measuring Range |
0.3 capacitive to 1.0 and 1.0 to 0.3
inductive
(72.5° capacitive to 0°
and 0° to 72.5°
inductive) |
| Resolution |
0.001 |
| Accuracy |
±3° |
| Frequency Range |
15Hz to 22 Hz and 45Hz to 65 Hz |
|
| |
| |
|
Kilowatt Hour
(kWHr) |
|
Measuring Range |
40,000 kWHr |
|
Autoranging Facility |
4 kWHr, 40 kWHr, 400 kWHr, 4000 kWHr,
40,000 kWHr |
|
Resolution |
| 1 WHr |
in 4 kWHr range |
| 10 WHr |
in 40 kWHr range |
| 100 WHr |
in 400 kWHr range |
| 1 kWHr |
in 4,000 kWHr range |
| 10 kWHr |
in 40,000 kWHr range |
|
|
Accuracy |
| kWHr >2 kWHr: |
3% of reading ±5
digits |
| kWHr <2kWHr: |
±0.08 kWHr |
|
|
All
Watts/VA/VAR/PF
Measurements |
| Frequency Range: |
DC and 15 Hz to 1 kHz |
| Current Range: |
10 Amp to 1400 Amps
rms |
| Voltage Range: |
1 Volt to 825 Volts
rms |
| Maximum Input: |
825 Volts rms/1400
Amps rms |
| Maximum Overload: |
1000 Volts rms/10,000
Amps |
|
|
| |
| Note: |
All measurements DC and 15Hz to 1 kHz. |
| |
Maximum overload 10,000 Amps or rms x frequency
<400,000 |
|
| |
|
Frequency
Measurement (from current or voltage sources) |
|
Measuring Range |
15 Hz to 1 kHz |
|
Resolution |
0.1 Hz |
|
Accuracy |
|
15 Hz to 22 Hz |
±0.5% of reading |
|
40Hz to 70 Hz |
±0.5% of reading |
|
15 Hz to 1000 Hz |
±1.0% of reading |
|
|
Current Range |
10 Amps to 1400 Amps rms |
|
Voltage Range |
1 Volt to 825 Volts rms |
|
|
|
|
|
|
Scope Function |
|
Current Measurement |
| Ranges: |
10A/20A/40A/100A/200A/400A/1000A/ |
| |
2000A |
| Resolution: |
|
1 Amp |
in 40 Amp range |
|
10 Amp |
in 400 Amp
range |
|
50 Amp |
in 2000 Amp
range |
|
| Accuracy: |
±3% of reading ±1
pixel |
| Max Overload: |
10,000 Amps |
|
|
Voltage Measurement |
| Ranges: |
4V/10V/20V/40V/100V/200V/400V/ |
| |
1000V |
| Resolution: |
|
100mV |
in 4 Volt range |
|
1 Volt |
in 40 Volt
range |
|
10 Volt |
in 400 Volt
range |
|
31.25 Volt |
in 1000 Volt
range |
|
| Accuracy: |
±2% of reading ±1
pixel |
| Max Overload: |
1000 Volts rms |
| Frequency Range: |
DC and 15 Hz to 600 Hz |
|
|
Time Base |
2.5 ms, 5 ms, 10 ms, 25 ms, and 50
ms/div |
|
Refresh Rate |
0.5 seconds |
|
Maximum Sampling Rate |
15.625 kHz |
|
| |
| |
|
Inrush Current |
|
Ranges |
40A, 400A and 2000 Amp |
|
Resolution |
|
10 mA |
in 40 Amp range |
|
100 mA |
in 400 Amp range |
|
1 Amp |
in 2000 Amp range |
|
|
Accuracy |
|
Current >10A: |
±5% of reading ±1
pixel |
|
Current <10A: |
±0.5A |
|
All measurements DC
and 15 kHz to 1 kHz |
|
|
Maximum Overload |
Maximum overload 10,000 A or
rms x frequency <400,000 Amps rms is a true-rms
measurement (AC + DC) |
|
Capture Time |
1s, 3s, 10s, 30s, 100s, and
300 seconds |
|
Maximum Sampling Rate |
15.625 kHz |
|
|
|
|
|
|
Interface |
|
Interface |
USB interface to a PC |
|
Software |
Power Log software for
download, analysis and reporting |
|
Upgrade Utility |
345 Upgrade Utility for
installing a new firmware version |
|
|
|
|
|
|
Logging Memory |
|
Logging Areas |
Three areas that can be used
individually or combined into one large area. |
|
Averaging Periods |
1s, 2s, 5s, 10s, 30s, 1 min,
5 min, 10 min, 15 min and custom |
|
|
|
|
|
|
Logging Timer |
|
Volts and Current Mode |
|
Average Time |
Logging Time (1
area) |
|
1 sec |
1 h 49 m |
|
2 sec |
3 h 38 m |
|
5 sec |
9 h 6 m |
|
10 sec |
18 h 12 m |
|
30 sec |
2 d 6 h 36 m |
|
1 min |
4 d 13 h 12 m |
|
5 min |
22 d 18 h 0 m |
|
10 min |
45 d 12 h 0 m |
|
15 min |
68 d 6 h 0 m |
|
|
|
|
|
Logging Time (3
areas) |
|
1 sec |
5 h 12 m |
|
2 sec |
10 h 24 m |
|
5 sec |
1 d 2 h 00 m |
|
10 sec |
2 d 4 h 00 m |
|
30 sec |
6 d 12 h 1 m |
|
1 min |
13 d 0 h 12 m |
|
5 min |
65 d 0 h 15 m |
|
10 min |
130 d 0 h 30 m |
|
15 min |
195 d 0 h 45 m |
|
|
V & A Harmonics Mode |
|
Average Time |
Logging Time (1
area) |
|
1 sec |
1 h 34 m |
|
2 sec |
1 h 8 m |
|
5 sec |
2 h 52 m |
|
10 sec |
5 h 44 m |
|
30 sec |
17 h 13 m |
|
1 min |
1 d 10 h 26 m |
|
5 min |
7 d 4 h 10 m |
|
10 min |
14 d 8 h 20 m |
|
15 min |
21 d 12 h 30 m |
|
|
|
|
|
Logging Time (3
areas) |
|
1 sec |
1 h 38 m |
|
2 sec |
3 h 16 m |
|
5 sec |
8 h 11 m |
|
10 sec |
16 h 23 m |
|
30 sec |
2 d 1 h 11 m |
|
1 min |
4 d 2 h 23 m |
|
5 min |
20 d 11h 25 m |
|
10 min |
81 d 0 h 50 m |
|
15 min |
121 d 13 h 15 m |
|
|
Single- and Three-Phase
Power Mode |
|
Average Time |
Logging Time (1
area) |
|
1 sec |
1 h 40 m |
|
2 sec |
3 h 21 m |
|
5 sec |
8 h 22 m |
|
10 sec |
16 h 45 m |
|
30 sec |
2 d 2 h 17 m |
|
1 min |
4 d 4 h 35 m |
|
5 min |
20 d 22 h 55 m |
|
10 min |
41 d 21 h 50 m |
|
15 min |
62 d 20 h 45 m |
|
|
|
|
|
Logging Time (3
areas) |
|
1 sec |
4 h 47 m |
|
2 sec |
9 h 34 m |
|
5 sec |
23 h 57 m |
|
10 sec |
1 d 23 h 54 m |
|
30 sec |
5 d 23 h 25 m |
|
1 min |
11 d 23 h 25 m |
|
5 min |
59 d 21h 5 m |
|
10 min |
119 d 18 h 10 m |
|
15 min |
179 d 15 h 15 m |
|
|