Technical Specifications

Current measurement
dc and ac
10Hz to 100Hz











 

Range 40A



 

Resolution:

10mA

Current Accuracy:

1.5% of reading + 15 digits

Trigger Level for Inrush:

0.50A

Trigger Level for Hz Filter OFF:

2.50A

Trigger Level for Hz Filter ON:

0.50A

Range 400A



 

Resolution:

100mA

Current Accuracy:

1.5% of reading + 5 digits

Trigger Level for Inrush:

5.0A

Trigger Level for Hz Filter OFF:

2.5A

Trigger Level for Hz Filter ON:

2.5A

Range 2000A;
1400A ac rms


 

Resolution:

1A

Current Accuracy:

1.5% of reading + 5 digits

Trigger Level for Inrush:

5A

Trigger Level for Hz Filter OFF:

8A

Trigger Level for Hz Filter ON:

8A

Crest Factor
50/60Hz

 

Range 40A

Crest Factor*:

2 @ 33A, 2.4 @ 27A

Range 400A

Crest Factor*:

2 @ 330A, 2.4 @ 270A

Range 2000A;

Crest Factor*:

2 @ 1000A, 2.4 @ 833A

1400A ac rms

Note*: Add 2% to error spec for CF >2

Current Measurement
ac 100.1Hz to 1kHz

 

 

 

 



 

Range 40A



 

Resolution:

10mA

Current Accuracy >10A:

3.5% of reading + 15 digits

Trigger Level for Inrush:

0.50A

Trigger Level for Hz Filter OFF:

2.50A

Trigger Level for Hz Filter ON:

0.50A

Range 400A



 

Resolution:

100mA

Current Accuracy >10A:

3.5% of reading + 5 digits

Trigger Level for Inrush:

5.0A

Trigger Level for Hz Filter OFF:

2.5A

Trigger Level for Hz Filter ON:

2.5A

Range 2000A;
1400A ac rms


 

Resolution:

1A

Current Accuracy >10A:

3.5% of reading + 5 digits

Trigger Level for Inrush:

5A

Trigger Level for Hz Filter OFF:

8A

Trigger Level for Hz Filter ON:

8A

Voltage
measurement (355 only) dc and ac 10Hz to 100Hz (600V and 1000V ranges have 10% over range to 660V and 1100V respectively)









 

Range 4V


 

Resolution:

10mV

Accuracy:

1.0% of reading + 10 digits

Trigger Level for Hz Filter OFF:

0.050V

Trigger Level for Hz Filter ON:

0.050V

Range 40V


 

Resolution:

10mV

Accuracy:

1.0% of reading + 5 digits

Trigger Level for Hz Filter OFF:

0.25V

Trigger Level for Hz Filter ON:

0.25V

Range 400V


 

Resolution:

100mV

Accuracy:

1.0% of reading + 5 digits

Trigger Level for Hz Filter OFF:

6V

Trigger Level for Hz Filter ON:

6V

Range 600V
ac rms

 

Resolution:

1V

Accuracy:

1.0% of reading + 5 digits

Trigger Level for Hz Filter OFF:

6V

Trigger Level for Hz Filter ON:

6V

Range 1000V dc

Resolution:

1V

 

Accuracy:

1.0% of reading + 5 digits

Voltage
measurement (355 only) ac 100.1Hz to 1kHz (600V and 1000V ranges have 10% over range to 660V and 1100V respectively)








 

Range 4V


 

Resolution:

1mV

Accuracy:

3.0% of reading + 10 digits

Trigger Level for Hz Filter OFF:

0.050V

Trigger Level for Hz Filter ON:

0.050V

Range 40V


 

Resolution:

10mV

Accuracy:

3.0% of reading + 5 digits

Trigger Level for Hz Filter OFF:

0.25V

Trigger Level for Hz Filter ON:

0.25V

Range 400V


 

Resolution:

100mV

Accuracy:

3.0% of reading + 5 digits

Trigger Level for Hz Filter OFF:

6V

Trigger Level for Hz Filter ON:

6V

Range 600V
ac rms

 

Resolution:

1V

Accuracy:

3.0% of reading + 5 digits

Trigger Level for Hz Filter OFF:

6V

Trigger Level for Hz Filter ON:

6V

Ohms measurement (355 only)




 

Range 400Ω
 

Resolution:

0.1Ω

Accuracy:

1.5% of reading + 5 digits

Range 4kΩ
 

Resolution:

1Ω

Accuracy:

1.5% of reading + 5 digits

Range 40kΩ
 

Resolution:

10Ω

Accuracy:

1.5% of reading + 5 digits

Range 400kΩ
 

Resolution:

100Ω

Accuracy:

1.5% of reading + 5 digits

Continuity beeper
(355 only)

On at ≤30Ω
Off at ≥100Ω

Frequency measurement

 

 

Measurement



 

Range:

5.0Hz to 1kHz

Resolution:

0.1Hz (15Hz to 399.9Hz); 1Hz (400Hz to 1kHz)

Accuracy:

0.2% + 2 counts (5.0Hz to 100Hz)

Accuracy:

0.5% + 5 counts (100.1Hz to 1kHz)

Trigger level:

Refer to current and voltage tables

 
 

General Specifications

Batteries

Six 1.5V 'AA' NEDA 15 A or IEC LR6 batteries

Battery life

100 hours (typical usage, backlight off)

Test leads

Rated to 1000V

Weight

814g (1.8 lb)

Jaw size

58mm (2.28 in)

Dimensions

300mm (L) x 98mm (W) x 52mm (D) (12" (L) x 3.75" (W) x 2" (D)

Safety rating

IEC 61010-2-032, 600V CAT IV, 1000V CAT III

 

 

Environmental Specifications

Operating temperature

0°C to +50°C (32°F to +122°F)

Storage temperature

-20°C to +60°C (-4°F to 140°F)

Operating humidity

0 to 95% (non-condensing)

Operating altitude

2000 meters

Storage altitude

10,000 meters

IP rating

42 (indoor use only)

Drop test requirements

1 meter

EMI, RFI, EMC

FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m,
performance criteria B, EN 61325

Temperature coefficients
 

Current: 0.1% of reading per °C outside 22°C to 24°C
Voltage: 0.1% of reading per °C outside 22°C to 24°C

 


Fluke | Hart | Reed | Yokogawa | EuroSMC | Kyoritsu | Megger | | Tenmars | Tektronix | Amprobe | CIE | Silvertronic |
 Site Map | Search | About Us | Contact Us

 

Rapid-Tech Equipment
ABN 79 883 184 102
1300 Ferntree Gully Road. Scoresby. Victoria 3179
P.O. Box 4243 Knox City Centre. Victoria 3152

Phone: +61 3 9763 3299     Fax: +61 3 9753 2132