Method of Detection |
Mean value |
|
Display
|
|
Digital display: |
3200 counts |
|
Bar-graph display: |
32 segments, LCD |
|
|
Measurement Cycle
|
|
Digital display: |
2 times/second |
|
Bar-graph display: |
12 times/second |
|
|
Range Switching |
Auto-range |
|
Ambient Temperature |
0°C to 50°C |
|
Humidity |
80% RH (no condensation) |
|
Temperature Coefficient
|
0.05% of range/°C or
less (within the ranges of 0°C to 18°C
and 28°C to 50°C
for measurement of 0 to 50A) |
|
Influence of External Magnetic Field |
0.0005% typical
|
|
Influence of Conductor Position |
Within accuracy
|
|
Circuit Voltage |
<300 Volts rms |
|
Safety Standard
|
EN 61010-1, EN 61010-2-032, 300V CAT. II, Pollution
degree 2 |
|
Withstanding Voltage |
3.7kV AC |
|
Battery Type |
1 x 3Volt Lithium battery (button cell) CR2032 |
|
Battery Life |
Approximately 90 hours (when continuously used) |
|
Auto Power-Off |
Approximately 10 minutes |
|
Measurable Conductor Size |
40mm maximum |
|
Weight |
200g |
|
Dimensions |
176mm (L) x 70mm (W) x 25mm (D) |
|
Operating Altitude |
2000m |