Model 5080A Multi-Product Calibrator Specifications

 

Technical Specifications

Measurement

Range

Best 1-Year Specification

DC Voltage

0 to ±1020V

±0.01% of setting

DC Current

0 to ±20.5A

±0.05% of setting

DC Power

10.9mW to 20.5kW

±0.11% of setting

AC Voltage

0 to ±1020V, 45Hz to 1kHz Sine

±0.1% of setting

AC Current

29mA to 20.5A, 45Hz to 1kHz Sine

±0.1% of setting

AC Power

10.9mW to 20.5kW, 45-65Hz, PF=1

±0.36% of setting

Resistance

0 to 190MΩ, 19 values in x1 and x1.9

±0.025% of setting

Phase

0° to 179.99°, 45Hz to 1kHz

±0.25° of setting

Frequency

45Hz to 1kHz

±50ppm of setting

 
 

General Specifications

Warm Up Time

Twice the time since last warmed up, to a maximum of 30 minutes

Setting Time

Less than 5 seconds for all functions and ranges except as noted

Standard Interfaces

RS-232 and Ethernet

Temperature Performance

Operating: 0°C to 50°C
Calibration (tcal): 15°C to 35°C
Storage: -20°C to +70°C

Temperature Coefficient

Temperature coefficient for temperatures outside tcal ±5°C is 10% of stated specification per °C for temperatures in the range of 0°C to 35°C. Above 35°C, the temperature coefficient is 20% of the stated specification per °C.

Relative Humidity

Operating: <80% to 30°C, <70% to 40°C, <40% to 50°C
Storage: <95%, non-condensing

Altitude

Operating: 2000 meters (6500ft) maximum
Non-Operating: 12200 meters (40000ft) maximum

Safety

Meets EN 61010-1-2001, CAN/CSA-C22.2 No. 61010-1-04. UL 61010-1: 2004

Analog Low Isolation

20V

EMC

Meets EN 613261: 2006

Line Power

Line Voltage (selectable): 100V, 120V, 220V, 240V
Line Frequency: 47Hz to 63Hz
Line Voltage Variation: +10% about line voltage setting

Power Consumption

600VA

Dimensions

Height: 19.3cm (7.6 ins)
Width: 43.2cm (17 ins)
Width with Handles: 44.3cm (17.5 ins)
Depth: 53.8cm (21.2 ins)

Weight (without options)

22kg (48lb)

Absolute Uncertainty Definition

The specification includes stability, temperature coefficient, linearity, line and load regulation, and traceability of the external standards used for calibration. It is not necessary to add anything to determine the total specification for the temperature range indicated.

Specification Confidence Interval

99%

 


Fluke | Hart | Reed | Yokogawa | EuroSMC | Kyoritsu | Megger | | Tenmars | Tektronix | Amprobe | CIE | Silvertronic |
 Site Map | Search | About Us | Contact Us

 

Rapid-Tech Equipment
ABN 79 883 184 102
1300 Ferntree Gully Road. Scoresby. Victoria 3179
P.O. Box 4243 Knox City Centre. Victoria 3152