Model 6500 PAT Tester Specifications

 
Specifications
The accuracy specification for the display range is defined as:
±(% of reading + digit counts) at 23°C ±5°C, ≤ 75% RH. Between 0°C and 18°C and between 28°C and 40°C,
accuracy specifications may degrade by 0.1 x (accuracy specification) per °C.

The measurement range meets the service operating errors specified in:
EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997.
 
 
Power-On Test

(The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency).

Display Range 90V to 264V
Accuracy at 50Hz ±(2% + 3 counts)
Resolution 1V
Input Impedance: > 1MΩ //2.2µF
Maximum Input Mains Voltage 300V
 
 
Earth Bond Test
Display Range 0 to 19.99
Accuracy (after bond test zeroing) ±(5% + 4 counts)
Resolution 0.01
Test Current
 
200mAac -0% + 40% into 1.99
25Aac +20% into
25MΩ at 230V
Open Circuit Voltage > 4Vac,  < 24Vac
Bond Test Zeroing can subtract up to 1.99
 
 
Insulation Test
Display Range 0 to 299M
Accuracy
 
±(5% + 2 counts) from 0.1Ω to 50MΩ
±(10% + 2 counts) from 50Ω to 299MΩ
Resolution

 
0.01MΩ (0Ω to 19.99MΩ)
0.1MΩ (20Ω to 199.9MΩ)
1MΩ (200Ω to 299MΩ)
Test Voltage 500Vdc -0% +25% at 500kΩ load
Test Current > 1mA at 500kΩ load, < 15mA at 0
Auto Discharge Time < 0.5sec for 1µF
Maximum Capacitive Load operational up to 1µF
 
 
Touch Current Test
Display Range 0 to 1.99mAac
Accuracy ±(4% + 2 counts)
Resolution 0.01mA
Internal Resistance (via probe) 2kΩ
Measuring Method Probe
Note: The appliance under test is energized at mains potential
 
 
Substitute Leakage Current Test
Display Range 0 to 19.99mAac
Accuracy ±(5% + 5 counts)
Resolution 0.01mA
Test Voltage 35Vac ±20%
Operational Error 10%
 
 
Load/Leakage Test: Load Current
Display Range 0 to 13A
Accuracy ±(4% + 2 counts)
Resolution 0.1A
Note: The appliance under test is energized at mains potential
 
 
Load/Leakage Test: Load Power
Display Range
 
0 to 999 VA
1.0 kVA to 3.2 kVA
Accuracy ±(5% + 3 counts)
Resolution
 
1 VA (0 to 999 VA)
0.1 kVA (1.0 kVA to 3.2 kVA)
Note: The appliance under test is energized at mains potential
 
 
Load/Leakage Test: Leakage Current
Display Range 0.25mA to 19.99mA
Accuracy ±(4% + 4 counts)
Resolution 0.01mA
Note: The appliance under test is energized at mains potential
 
 
PELV Test
Accuracy at 50Hz ±(2% + 3 counts)
Overload Protection 300Vrms
Warning Threshold 25Vrms
 
 
General Specifications
Size 200mm x 275mm x 100mm
Weight 3 kg
Warranty Two Years

 