Specifications |
The accuracy specification for the display
range is defined as:
±(% of reading + digit counts) at 23°C ±5°C, ≤ 75% RH. Between 0°C
and 18°C and between 28°C and 40°C,
accuracy specifications may degrade by 0.1 x (accuracy
specification) per °C.
The measurement range meets the service operating errors specified
in:
EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997. |
|
|
|
|
|
|
Power-On Test |
|
(The test indicates reversed L-N, missing PE, and
measures the mains voltage and frequency). |
| Display Range |
90V to 264V |
| Accuracy at 50Hz |
±(2% + 3 counts) |
| Resolution |
1V |
| Input Impedance: |
> 1MΩ //2.2µF |
| Maximum Input Mains Voltage |
300V |
|
|
|
|
|
|
Earth Bond Test |
| Display Range |
0 to 19.99Ω |
| Accuracy (after bond test
zeroing) |
±(5% + 4 counts) |
| Resolution |
0.01Ω |
Test Current
|
200mAac -0% + 40% into 1.99Ω
25Aac +20% into 25MΩ at 230V |
| Open Circuit Voltage |
> 4Vac, < 24Vac |
| Bond Test Zeroing |
can subtract up to 1.99Ω |
|
|
|
|
|
|
Insulation Test |
| Display Range |
0 to 299MΩ |
Accuracy
|
±(5% + 2 counts) from 0.1Ω
to 50MΩ
±(10% + 2 counts) from 50Ω to 299MΩ |
Resolution
|
0.01MΩ (0Ω to
19.99MΩ)
0.1MΩ (20Ω to 199.9MΩ)
1MΩ (200Ω to 299MΩ) |
| Test Voltage |
500Vdc -0% +25% at 500kΩ
load |
| Test Current |
> 1mA at 500kΩ
load, < 15mA at 0Ω |
| Auto Discharge Time |
< 0.5sec for 1µF |
| Maximum Capacitive Load |
operational up to 1µF |
|
|
|
|
|
|
Touch Current Test |
| Display Range |
0 to 1.99mAac |
| Accuracy |
±(4% + 2 counts) |
| Resolution |
0.01mA |
| Internal Resistance (via probe) |
2kΩ |
| Measuring Method |
Probe |
| Note: The appliance
under test is energized at mains potential |
|
|
|
|
|
|
Substitute Leakage Current Test |
| Display Range |
0 to 19.99mAac |
| Accuracy |
±(5% + 5 counts) |
| Resolution |
0.01mA |
| Test Voltage |
35Vac ±20% |
| Operational Error |
10% |
|
|
|
|
|
|
Load/Leakage Test: Load Current |
| Display Range |
0 to 13A |
| Accuracy |
±(4% + 2 counts) |
| Resolution |
0.1A |
| Note: The appliance
under test is energized at mains potential |
|
|
|
|
|
|
Load/Leakage Test: Load Power |
Display Range
|
0 to 999 VA
1.0 kVA to 3.2 kVA |
| Accuracy |
±(5% + 3 counts) |
Resolution
|
1 VA (0 to 999 VA)
0.1 kVA (1.0 kVA to 3.2 kVA) |
| Note: The appliance
under test is energized at mains potential |
|
|
|
|
|
|
Load/Leakage Test: Leakage Current |
| Display Range |
0.25mA to 19.99mA |
| Accuracy |
±(4% + 4 counts) |
| Resolution |
0.01mA |
| Note: The appliance
under test is energized at mains potential |
|
|
|
|
|
|
PELV Test |
| Accuracy at 50Hz |
±(2% + 3 counts) |
| Overload Protection |
300Vrms |
| Warning Threshold |
25Vrms |
|
|
|
|
|
|
General Specifications |
| Size |
200mm x 275mm x 100mm |
| Weight |
3 kg |
| Warranty |
Two Years |
|