Model 718 Pressure Calibrator -
Specifications |
|
|
|
|
Technical Specifications |
| Fluke 718 Series |
Measure Pressure |
| |
Accuracy: |
| |
Functions: |
| |
Note: |
|
|
(Internal sensor) |
|
0.05% full scale |
|
Zero, Min, Max, Hold, Damp |
|
dry air, non-corrosives only |
|
| Fluke 718 1G |
Range: |
| |
Resolution: |
| |
Over Pressure: |
| |
Functions: |
|
|
-1 to 1 PSI, -68.9 mbar to 68.9
mbar (-6.89 kPa to 6.89 kPa) |
|
0.0001 PSI, 0.001 mbar, 0.0001 kPa |
|
5 x full scale |
|
Zero, Min, Max, Hold, Damp |
|
| Fluke 718 30G |
Range: |
| |
Resolution: |
| |
Over Pressure: |
| |
Functions: |
|
|
-12 to 30 PSI, (-850 mbar to 2
bar, -85 to 206.84 kPa) |
|
0.001 PSI, 0.1 mbar, 0.01 kPa |
|
5 x full scale |
|
Zero, Min, Max, Hold, Damp |
|
| Fluke 718 100G |
Range: |
| |
Resolution: |
| |
Over Pressure: |
| |
Functions: |
|
|
-12 to 100 PSI, (-850 mbar to 7
bar, -85 to 689.48 kPa) |
|
0.01 PSI, 0.1 mbar, 0.01 kPa |
|
2 x full scale |
|
Zero, Min, Max, Hold, Damp |
|
| Fluke 718 300G |
Range: |
| |
Resolution: |
| |
Over Pressure: |
| |
Functions: |
|
|
-12 to 300 PSI, (-850 mbar to 20
bar, -85 to 2068.42 kPa) |
|
0.01 PSI, 1 mbar, 0.1 kPa |
|
375 PSI, 25 bar |
|
Zero, Min, Max, Hold, Damp |
|
| Fluke 718 Series using 700 Series |
| Pressure Modules |
|
Range: |
|
|
|
|
Resolution: |
|
|
Accuracy: |
|
|
Functions: |
| |
|
|
| |
|
(via pressure module connector
using optional Pressure Module) |
|
29 pressure modules, 0 - 1 in H20
to 10,000 PSI, 2.5 mbar to 700 |
|
bar. Over pressure per pressure
module specifications. |
|
Per pressure module specs |
|
To 0.025% of full span, per
pressure module specifications |
|
Zero, Min, Max, Hold, Damp |
| Note: media compatibility per pressure module specs. |
|
| Fluke 718 Series via Built in Pump |
| |
|
| |
Range: |
| |
|
| |
|
|
Loop Power |
|
| |
Accuracy: |
| |
|
| |
|
|
mA Measure |
|
| |
Range: |
| |
Resolution: |
| |
Accuracy |
|
| |
| |
|
-12 PSI or -850 mbar to full scale
Supported Pressure Units; psi, |
|
in H20 (4°C),
in H20 (20°C), cm H20 (20°C),
bar, mbar, kPa, in Hg, |
|
mmHg, kg/cm |
|
|
|
±10% |
|
Note: Drive; 20mA into 1000 for
battery > 6.8V; 700 for battery |
|
5.8 to 6.8V |
|
|
|
0 mA to 24 mA |
|
0.0001 mA |
|
0.015% + 1 count |
|
|
|
|
|
|
|
General Specifications |
| Maximum
voltage |
30 volts:
Non-operating |
|
Operating
temperature |
-10șC to 55șC |
|
Non-operating
temperature |
-40șC to 60șC |
|
Relative humidity
(% RH operating without condensation) |
95% (10șC to 30șC);
75% (30șC to 40șC);
45% (40șC to 50șC); 35% (50șC to 55șC) |
|
Operating altitude |
3,000m max |
|
Vibration |
Random, 2g, 5-500 Hz |
|
Shock |
1m drop test |
|
Vibration |
Random,
2g, 5Hz - 500Hz |
|
Safety |
CSA C22.2 No.
1010.1:1992 |
| EMC
|
EN50082-1:
1992 and EN55022: 1994 Class B |
|
Power |
Two 9V battery
ANSI/NEDA 1604A or IEC 6LR61 |
| Battery
life |
4 to 20
hours typical, depending on functions used |
|
Size
|
216
mm (L) x 94mm (W) x 66mm (D)
(8.5 in X 3.72 in x 2.6 in) |
|
Weight
|
992g (35 oz) |
|
Display: |
LCD, 5 digit pressure and
current simultaneous |
|
Warranty: |
3 years (one year on
pressure pump) |
|
|
|
|