Model 726 Multifunction Calibrator - Specifications

 
Measurement Accuracy
Voltage DC 30.000 V
  20.000 V
  90.00 mV
  -10mV to 75.00mV
0.01% + 2mV (upper display)
0.01% + 2mV (lower display)
0.01% + 2mV to 10mV
0.025% + 1 count (via TC connection)
Current DC

24.000 mA

0.01% + 2mA
Resistance 0.0 to 4000.0 Ω
±0.015%
Frequency 2.0 to 1000.0 CPM
  1.0 to 1000.0 Hz
  1.00 to 15.00 kHz
  Sensitivity
0.05% + 0.1 cpm
0.05% + 0.1 Hz
0.05% + 0.1 kHz
1V peak-to-peak-minimum
Pressure

Accuracy

from 0.025% of range using any of 29 pressure modules.*
Note: * for detailed specifications refer to pressure modules in Options and Accessories.
           Modules available for differential, gage, vacuum, absolute, dual and high pressure.
 
Source Accuracy
Voltage DC 100.00 mV
  20.000 V
  -10mV to 75.00mV
0.01% + 10mV
0.01% + 2mV
0.025% + 1 count (via TC connection)
Current DC

24.000 mA (Source)

24.000 mA (Simulate)

0.01% + 2mA
0.01% + 2mA
Resistance
 
 
   
   
   
   
   
Range
 
Accuracy
 
Excitation
Current
5Ω to 400Ω 0.015% + 0.1Ω 0.1mA to 0.5mA
5Ω to 400Ω 0.015% + 0.05Ω 0.5mA to 3mA
400Ω to 1500Ω 0.015% + 0.5Ω 0.5mA to 0.8mA
1500Ω to 4000Ω 0.015% + 0.5Ω 0.5mA to 0.4mA
Percent of reading + floor
Frequency 2.0 to 1000.0 CPM
  1.0 to 1000.0 Hz
  1.0 to 10.0 kHz
  10.0 to 15.0 kHz
  Waveform
0.05%
0.05%
0.25%
0.5%
5V p-p square-wave, -0.1V offset
 
 
RTD's and Thermocouples
Measure and Source Accuracy
  Cu10
  NI-120
  PT-100 (385)
  PT-100 (392)
  PT-100 (391-JIS)
  PT-200 (385)
  PT-500 (385)
  PT-1000 (385)
 

Resolution:

 

J:

 

K:

 

T:

 

E:

 

R:

 

S:

 

B:

 

L:

 

U:

 

N:

 

XK:

 

BP:

   

1.8°C

-10°C to 250°C

0.15°C

-80°C to 260°C

0.25°C

-200°C to 800°C

0.15°C

-200°C to 630°C

0.25°C

-200°C to 630°C

0.75°C

-200°C to 630°C

0.35°C

-200°C to 630°C

0.15°C

-200°C to 630°C

0.01°C

 

0.4°C

 

0.5°C

 

0.4°C

 

0.4°C

 

1.4°C

 

1.4°C

 

1.4°C

 

0.4C

 

0.4C

 

0.6°C

 

0.4°C

 

1.1°C

 
 
 
Thermocouple Resolution
J, K, T, E, L, N, U 0.1ºC, 0.1ºF
B, R, S 1ºC, 1ºF
 
 
Specifications
Ramp Functions
  Source Functions
  Ramps
 
Voltage, current, resistance, frequency, temperature
Slow ramp, Fast ramp, 25% step-ramp
Step Functions
  Source Functions
  Steps
 
Voltage, current, resistance, frequency, temperature
25% of range, 100% of range
Loop Power Function
  Voltage
  Accuracy
  Maximum Current
 
24V
10%
22mA (short circuit protected)
 
 
Mechanical and General Specifications
Storage Temperature -20ºC to 71ºC
Operating Temperature -10ºC to 55ºC
Safety Approvals EN 61010-1: 1993, ANSI/ISA S82.01-1994
CSA C22.2 No. 1010.1:1992
Operating Altitude 3000 meters
Size 200mm x 96mm x 47mm (7.9" x 3.8" x 1.9")
Weight 650g (23oz)
Battery Four AA alkaline batteries.
Battery Replacement Separate battery compartment, accessible without breaking calibration seal.
Side Port Connections Pressure module connector, also used for remote real-time programming.

 