Model 726 Multifunction Calibrator -
Specifications |
|
|
|
|
Measurement Accuracy |
| Voltage DC |
30.000 V |
| |
20.000 V |
| |
90.00 mV |
| |
-10mV to 75.00mV |
|
| 0.01% + 2mV (upper display) |
| 0.01% + 2mV (lower display) |
| 0.01% + 2mV to 10mV |
| 0.025% + 1 count (via TC connection) |
|
|
|
|
| Resistance |
0.0 to 4000.0 Ω |
|
|
| Frequency |
2.0 to 1000.0 CPM |
| |
1.0 to 1000.0 Hz |
| |
1.00 to 15.00 kHz |
| |
Sensitivity |
|
| 0.05% + 0.1 cpm |
| 0.05% + 0.1 Hz |
| 0.05% + 0.1 kHz |
| 1V peak-to-peak-minimum |
|
|
|
| from 0.025% of range using any of 29 pressure modules.* |
|
|
| Note: * for detailed specifications refer to pressure
modules in Options and Accessories. |
| Modules available for differential, gage, vacuum,
absolute, dual and high pressure. |
|
|
|
|
Source Accuracy |
| Voltage DC |
100.00 mV |
| |
20.000 V |
| |
-10mV to 75.00mV |
|
| 0.01% + 10mV |
| 0.01% + 2mV |
| 0.025% + 1 count (via TC connection) |
|
| Current DC |
24.000 mA (Source) |
|
24.000 mA (Simulate) |
|
|
|
|
Range
|
Accuracy
|
Excitation
Current |
| 5Ω
to 400Ω |
0.015% + 0.1Ω |
0.1mA to
0.5mA |
| 5Ω
to 400Ω |
0.015% + 0.05Ω |
0.5mA to 3mA |
| 400Ω
to 1500Ω |
0.015% + 0.5Ω |
0.5mA to
0.8mA |
|
1500Ω to 4000Ω |
0.015% + 0.5Ω |
0.5mA to
0.4mA |
| Percent of reading + floor |
|
| Frequency |
2.0 to 1000.0 CPM |
| |
1.0 to 1000.0 Hz |
| |
1.0 to 10.0 kHz |
| |
10.0 to 15.0 kHz |
| |
Waveform |
|
| 0.05% |
| 0.05% |
| 0.25% |
| 0.5% |
| 5V p-p square-wave, -0.1V offset |
|
|
|
|
|
|
|
RTD's and Thermocouples |
| Measure and Source Accuracy |
| |
Cu10 |
| |
NI-120 |
| |
PT-100 (385) |
| |
PT-100 (392) |
| |
PT-100 (391-JIS) |
| |
PT-200 (385) |
| |
PT-500 (385) |
| |
PT-1000 (385) |
| |
Resolution: |
| |
J: |
| |
K: |
| |
T: |
| |
E: |
| |
R: |
| |
S: |
| |
B: |
| |
L: |
| |
U: |
| |
N: |
| |
XK: |
| |
BP: |
|
| |
|
|
1.8°C |
-10°C to 250°C |
|
0.15°C |
-80°C to 260°C |
|
0.25°C |
-200°C to 800°C |
|
0.15°C |
-200°C to 630°C |
|
0.25°C |
-200°C to 630°C |
|
0.75°C |
-200°C to 630°C |
|
0.35°C |
-200°C to 630°C |
|
0.15°C |
-200°C to 630°C |
|
0.01°C |
|
|
0.4°C |
|
|
0.5°C |
|
|
0.4°C |
|
|
0.4°C |
|
|
1.4°C |
|
|
1.4°C |
|
|
1.4°C |
|
|
0.45°C |
|
|
0.45°C |
|
|
0.6°C |
|
|
0.4°C |
|
|
1.1°C |
|
|
|
|
|
|
|
|
Thermocouple Resolution |
|
J, K, T, E, L, N, U |
0.1ºC, 0.1ºF |
|
B, R, S |
1ºC, 1ºF |
|
|
|
|
|
|
Specifications |
| Ramp Functions |
| |
Source Functions |
| |
Ramps |
|
| |
| Voltage, current, resistance, frequency, temperature |
| Slow ramp, Fast ramp, 25% step-ramp |
|
| Step Functions |
| |
Source Functions |
| |
Steps |
|
| |
| Voltage, current, resistance, frequency, temperature |
| 25% of range, 100% of range |
|
| Loop Power Function |
| |
Voltage |
| |
Accuracy |
| |
Maximum Current |
|
| |
| 24V |
| 10% |
| 22mA (short circuit protected) |
|
|
|
|
|
|
|
Mechanical and General
Specifications |
|
Storage Temperature |
-20ºC to 71ºC |
|
Operating
Temperature |
-10ºC to 55ºC |
|
Safety Approvals |
EN 61010-1: 1993,
ANSI/ISA S82.01-1994
CSA C22.2 No. 1010.1:1992 |
|
Operating Altitude |
3000 meters |
|
Size |
200mm x 96mm x 47mm (7.9" x
3.8" x 1.9") |
|
Weight |
650g (23oz) |
|
Battery |
Four AA alkaline
batteries. |
|
Battery Replacement |
Separate battery compartment,
accessible without breaking calibration seal. |
| Side
Port Connections |
Pressure
module connector, also used for remote real-time programming. |
|
|
|