Rapid-Tech Equipment Logo Combo Kit Power Quality Recorder Power Quality Analyzer Multifunction Digital Multimeter

Nationwide - Call 1800 358 531 

 Fluke Test Instruments Logo

Model 787 ProcessMeter™
Specifications

 

Technical Specifications

DC Current Output (Internal battery operation)

Range and Resolution
0.000 to 20.000 mA or 4.000 to 20.000 mA (selectable at power-up). Over-range to 24.000 mA
Drive Capability

12 V compliance, or 500 ohms @20 mA
Accuracy (% of span)

0.05 %

DC Current Simulate (External 24 volt loop supply)

Range and Resolution
0.000 to 20.000 mA or 4.000 to 20.000 mA (selectable at power-up). Over-range to 24.000 mA
Drive Capability

1000 ohms @20 mA
Accuracy (% of span)

0.05 %

Current Adjustment Modes

Range and Resolution
Manual: Coarse Fine: 25% step
Automatic: Slow Ramp, Fast Ramp, 25% step

 
 
 

Measurement Accuracy

VDC

Range and Resolution:
400.0 mV, 4.000V, 40.00V, 400.0V, 1000V
Best Accuracy (% of reading + LSD):

0.1% + 1

VAC (true RMS)
to 1 kHz
*

Range and Resolution:
400.0 mV, 4.000V, 40.00V, 400.0V, 1000V
Best Accuracy (% of reading + LSD):

0.7% + 2

mA DC

Range and Resolution:
30.000 mA
Best Accuracy (% of reading + LSD:

0.05% + 2

A DC

Range and Resolution:
1.000 A (0.440 A continuous)
Best Accuracy (% of reading + LSD):

0.2% + 2

A AC

Range and Resolution:
1.000 A (0.440 A continuous)
Best Accuracy (% of reading + LSD):

1% + 2

Resistance

Range and Resolution:
400.0 Ohms, 4.000 kOhms, 40.00 kOhms, 400.0 kOhms, 4.000 MOhms, 40.00MOhms
Best Accuracy (% of reading + LSD):

0.2% + 1

Frequency (0.5 Hz to 20 kHz)

Range and Resolution:
199.99 Hz, 1999.9 Hz, 19.999 kHz, 199.99 kHz
Best Accuracy (% of reading + LSD):

0.005% + 1

Diode Test

Range and Resolution:
2.400 V (measures diode voltage drop)
Best Accuracy (% of reading + LSD):

2% + 1

Continuity

Range and Resolution
Beeps for resistance < approx. 100 ohms

 
 

General Specifications

Maximum voltage applied between any jack and Earth Ground

1000 V rms

Storage Temperature

-40 ēC to 60 ēC

Operating Temperature

-20 ēC to 55 ēC

Temperature Coefficient

0.05 x (specified accuracy) per ēC (for temperatures < 18 ēC or > 28 ēC)

Relative Humidity

95% up to 30 ēC; 75% up to 40 ēC; 45% up to 50 ēC; 35% up to 55 ēC

Vibration

Random, 2g, 5-500 Hz

Shock

1 meter drop test

Safety

Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92 Overvoltage Category III

Size

32 mm H x 87 mm W x 187 mm L (1.25 in H x 3.41 in W x 7.35 in L)

Size, with holster and Flex-Stand

52 mm H x 98 mm W x 201 mm L (2.06 in H x 3.86 in W x 7.93 in L)

Weight

369 g (13 oz); with holster and Flex-Stand 638 g (22.5 oz)

Battery

Single 9V Alkaline battery (ANSI/NEDA 1604A or IEC 6LR61)

Battery Life

50 hours typical (measurement), 12 hours typical (sourcing 12 mA)

Warranty

3 years

 


Fluke | Hart | Reed | Yokogawa | EuroSMC | Kyoritsu | Megger | | Tenmars | Tektronix | Amprobe | CIE | Silvertronic |
 Site Map | Search | About Us | Contact Us

 

Rapid-Tech Equipment
ABN 79 883 184 102
1300 Ferntree Gully Road. Scoresby. Victoria 3179
P.O. Box 4243 Knox City Centre. Victoria 3152

Phone: +61 3 9763 3299     Fax: +61 3 9753 2132