Model 80i-110s Features |
|
80i-110s AC/DC Current Clamp for use with DMM's,
Oscilloscopes, ScopeMeters and Power Quality Analyzers
The 80I-110s
is compatible with any Fluke ScopeMeter Test Tool, Power
Harmonics Analyzer, Oscilloscope, Multimeter, or other
voltage measurement device that has the following features:
BNC input connectors or if using a meter convert the banana
plugs to a BNC connector using the adapter PM9081/001.
|
|

|
Features
- DC Range 0.1 Amp to 100 Amp.
- AC Range 0.1 Amp to 70 Amp.
- Accuracy 0.1A to 10A, DC to 1kHZ ± 3% + 50mA;
up to 100A add 15%; up to 20kHz add 12%.
- Frequency Response (-3db) 100kHz.
- Zero Error Adjustment.
- Maximum Conductor Diameter 0.46" (11.8mm).
- Maximum Conductor Size 1 AWG.
- Output Levels 10mV/A, 100mV/A.
- Output Cable 1.6 meters with BNC Termination.
- Battery Life 40 Hours.
- Safety CAT III, 600V; CAT III, 300V.
- Warranty 1 year.
|
|
|
|
|
Technical Specifications |
|
Nominal Current Range
|
10 Amps AC/DC
100 Amps AC/DC |
|
Continuous Current Range
|
0.1 Amp to 10 Amps AC/DC
1 Amp to 100 Amps AC/DC |
|
Maximum Non-Destructive
Current |
140 Amps to 2kHz |
|
Lowest Measurable Current |
0.1 Amp |
|
Basic Accuracy
|
3% + 50mA (@10 Amps)
(% of reading + floor-spec) |
|
Useable Frequency |
DC to 100 kHz |
|
Output Level(s)
|
100mV/Amp
10mV/Amp |
|
Zero Error Adjustment |
Yes |
|
Safety |
CAT III, 300 Volts, CAT II, 600
Volts |
|
Maximum Voltage |
600 Volts AC |
|
| |
| |
|
General Specifications |
|
Warranty |
One year |
|
Maximum Conductor Diameter |
11.8mm |
|
Output Cable Length |
1.6 meters |
|
BNC Adapter |
Yes |
|
Battery Life |
9 Volt, 55-hours |
|
|