Voltage DC
|
Maximum voltage:
Accuracy:
Maximum resolution: |
1000V
±(0.05% +1)
10µV |
|
Voltage AC
|
Maximum voltage:
Accuracy:
AC bandwidth:
Maximum resolution: |
1000V
±(0.7% +2) True-RMS
20kHz*
0.1mV |
|
Current DC
|
Maximum amps:
Accuracy:
Maximum resolution: |
10A (20A for 30 seconds max)
±(0.02% +2)
0.01µA |
|
Current AC
|
Maximum amps:
Accuracy:
Maximum resolution: |
10A (20A for 30 seconds max)
±(1.0% +2) True-RMS
0.1µA |
|
Resistance
|
Maximum resistance:
Accuracy:
Maximum resolution: |
50MΩ
±(0.2% +1)
0.1Ω |
|
Capacitance
|
Maximum capacitance:
Accuracy:
Maximum resolution: |
9.999µF
±(1% +2)
0.01nF |
|
Frequency
|
Maximum frequency:
Accuracy:
Maximum resolution: |
200kHz
±(0.005% +1)
0.01Hz |
|
Duty Cycle
|
Maximum duty cycle:
Accuracy:
Maximum resolution: |
99.90%
±(0.2% per kHz +0.1%)
0.10% |
|
Temperature Measurement
|
Range:
|
-200.0°C to 1090°C
(-328°F to 1994°F) |
|
80BK Temperature Probe
|
Range:
Accuracy: |
-40°C to 260°C
(-40°F to 500°F)
2.2C or 2% whichever is greater |
|
Conductance
|
Maximum conductance
Accuracy:
Maximum resolution: |
60.00nS
±(1% +10)
0.01nS |
|
Diode
|
Range:
Accuracy:
Resolution: |
3V
±(2% +1)
1mV |
|
Duty Cycle Range |
Accuracy: |
Within ±(0.2% per kHz
+0.1%) |
|
Measurements Restriction in Ex-hazardous area |
Voltage:
Current: |
≤65V
≤5A |
|
Environmental Specifications
|
Operating temperature:
Storage temperature:
Humidity (without condensation):
Operating altitude: |
-20°C to +55°C
-40°C to +60°C
0% to 90% (0°C to 35°C)
0% to 70% (35°C to 55°C)
2000m |
|
Safety Specifications
|
Overvoltage category:
Agency approvals:
ATEX specification:
Agency approvals: |
EN 61010-1 to 1000V CAT III,
600V CAT IV.
CSA, TUV
EX II 2 G EEx ia IIC T4
ZELM 05 ATEX 027 |
|
Mechanical and General Specifications
|
Size including holster:
Weight:
Weight with holster:
Display (digital):
Display (analog):
Battery life (Alkaline):
Shock:
Vibration:
Warranty: |
201mm x 98mm x 52mm
1.09 lbs
1.46 lbs
6000 counts updates 4/sec
19,999 counts in high-resolution mode.
32 segments, updates 40/sec
400 hours typical, without backlight
1 meter drop
per IEC 61010-1:2001
Per MIL-PRF-28800 for a class 2 instrument
1 year |