Voltage DC |
|
Range: |
0 to 600.0V |
|
Accuracy: |
1% ±5 counts |
|
|
Voltage AC (True RMS) |
|
Range: |
0 to 600.0V |
|
Accuracy: |
1% ±5 counts (50/60Hz) |
|
|
Current AC (True RMS) |
|
Range: |
0 to 600.0A |
|
Accuracy: |
2% ±5 counts (50/60Hz) |
|
|
Current DC |
|
Range: |
0 to 200.0µA |
|
Accuracy: |
1% ±5 counts |
|
|
Resistance |
|
Range: |
0 to 9999Ω |
|
Accuracy: |
1.5% ±5 counts |
|
|
Continuity |
≤ 30Ω |
|
Temperature* (Type K Thermocouple) |
|
Range: |
-10°C to 400°C
(-14°F to 752°F) |
|
Accuracy: |
±1% + 0.8°C
(±1% + 1.5°F)
typical |
|
Range: |
-40°C to 10°C
(-40°F to 14°F) |
|
Accuracy: |
±5.0% + 1.5°C
(±5.0% + 3.3°F)
typical |
|
|
Capacitance |
|
Range: |
1 to 1000µF |
|
Accuracy: |
1.9% ±2 counts |
|