Model 922 Air Flow Meter - Specifications

 
 
Technical Specifications

Air Pressure




 

Range/Resolution/Accuracy
 



 

±4000 Pascal's / 1 Pascal / ±1% + 1 Pascal

±16 in H2O / 0.001 in H2O / ±1% + 0.01 in H2O

±400 mm H2O / 0.1 mm H20 / ±1% + 01 mm H2O

±40 mbar / 0.01 mbar / ± 1% + 0.01 mbar

±0.6 PSI /0.0001 PSI / ±1% + 0.0001 PSI

Air Velocity
 


 

Range/Resolution/Accuracy



 

250 to 16,000 fpm / ±2.5% of reading at

2000 fpm (10.00 m/s)

1 to 80 m/s / 0.001 m/s / ±2.5% of reading at

2000 fpm (10.00 m/s)

Air Flow (Volume)





 

Range/Resolution/Accuracy
 




 

0 to 99,999cfm / 1 cfm / Accuracy is a function of

velocity and duct size.

0 to 99,999 / 1m3/hr / Accuracy is a function of

velocity and duct size.

0 to 99,999 I/s / 1 I/s / Accuracy is a function of

velocity and duct size.

Temperature
 

Range/Resolution/Accuracy
 

0°C to 50°C / ±1% + 2°C / 0.1°C

32°F to 122°F / ±1% + 4°F / 0.1°F

 
 
General Specifications

Operating Temperature

0°C to +50°C (+32°F to +122°F)

Storage Temperature

-40°C to +60°C (-40°F to +140°F)

Relative Humidity

0% to 90%, non-condensing

IP Rating

IP40

Operating Altitude

2000 meters

Storage Altitude

12000 meters

EMI, RFI, EMC

Meets requirements for EN61326-1

Vibration

MIL-PREF-28800F, Class 3

Maximum Pressure at Each Port

10 PSI

Data Storage Capacity

99 readings

Warranty

2-years

Power

Four AA batteries

Battery Life

280 hours without backlight, 60 hours with backlight

 