Overview
The new Fluke iFlex flexible
current probes expand the measurement range of a select
range of Fluke model
current meters to 2500 Amps AC while providing the ultimate
measurement flexibility. The iFlex probes connect directly
to the meter, displaying current measurements without error
prone scaling factors.
The 1.8 meter (6 foot) cord allows
separation between the measurement location and the clamp
meter making it easier to view the display. The large loop
size and thin cross section allow measurement of awkward
sized conductors and improved wire access in crowded spaces.
Available in 25cm (10") and 45cm (18") sizes.
|
|
 |
Features
- Expands the measurement range to 2500 amps AC while
providing increased display flexibility, ability to
measure awkward sized conductors and improved wire
access.
- CAT III 1000V, CAT IV 600V.
- 7.5mm coil diameter allows measurement in tight
spaces.
- Ergonomic design allows easy operation with one
hand.
- 1.8 meter (6 foot) cable.
- 3-year warranty.
|
|
How-to-open the i2500-10 and i2500-18 iFlex flexible current
probes:
|
| Twist to unlock |
Pull to open |
 |
 |
|
|
|
|
Specifications |
|
|
|
|
|
Model i2500-10 and
i2500-18 |
|
Range |
Resolution |
Accuracy |
|
AC Current* |
|
2500 Amps |
0.1A |
3% of reading ± 5 digits** |
|
Frequency* |
|
500Hz |
0.1Hz |
0.5% of reading
± 5 digits |
|
External Magnetic Field
Rejection |
|
40dB (with
cable >10cm from the coupling |
|
Inrush |
|
- |
|
Safety Rating |
|
CAT III
1000V, CAT IV 600V |
|
|
|
|
|
|
|
Note* |
When used with compatible Fluke meter, the
Accuracy Stated includes probe and meter
accuracy. |
|
Note** |
For position accuracy at non-optimum
positions, see Position sensitivity
specifications table below. |
|
|
| |
|
 |
|
Position Sensitivity Specifications |
| Distance from optimum |
Model i2500-10 |
Model i2500-18 |
Additional iFlex Error |
| A |
12.7mm (0.5") |
35.6mm (1.4") |
±0.5% |
| B |
20.3mm (0.8") |
50.8mm (2.0") |
±1.0% |
| C |
35.6mm (1.4") |
63.5mm (2.5") |
±2.0% |
Measurement uncertainty assumes centralized primary
conductor at optimum position, no
external or magnetic field, and within operating
temperature.
|
|
| |
|
Ordering Information |
|
|
|
|
|
Fluke i2500-10 |
|
iFlex™
Flexible Current Probe |
|
Fluke i2500-18 |
|
iFlex™
Flexible Current Probe |
|