Rapid-Tech Equipment Logo Combo Kit Power Quality Recorder Power Quality Analyzer Multifunction Digital Multimeter

Nationwide - Call 1800 358 531 

 Fluke Test Instruments Logo Ti25 Thermal Imager Specifications

 

Specifications
Temperature
Temperature measurement range: -20°C to +350°C (two ranges)
(not calibrated below -10C°)  
Accuracy: ±2°C or 2% (whichever is greater)
On-screen emissivity correction: Yes
Image Performance
Field of view: 23° x 17°
Special resolution (IFOV): 2.5 mRad
Minimum focus distance: Thermal lens 15 cm (6 ins)
  Visible light lens 46 cm (18 ins)
Focus: manual
Image frequency: 9 Hz refresh rate
Detection type: 160 x 120 focal plane array, uncooled
  microbolometer
Infrared lens type: 20 mm F = 0.8 lens
Thermal sensitivity (NETD): 0.1°C at 30°C (100 mk)
Infrared spectral band: 7.5 µm to 14 µm
Visual camera: 640 x 480 resolution
Image Presentation
Palettes:
 
Ironbow, blue-red, high contrast, amber, hot metal, grey
Level and span: Smooth auto-scaling and manual scaling
  of level and span
Minimum span (in manual mode): 2.5°C
Minimum span (in manual auto mode):
5°C (18°F)
IR-Fusion information: Full infrared with MAX, MID, or MIN automatic blending; and picture-in-picture with MAX, MID, or MIN automatic blending (Visual and IR blending)
Picture-in-Picture (PIP):
 
Three levels of on-screen IR blending displayed in center (320 x 240 pixels)
Full screen (PIP off):
 
Three levels of on-screen IR blending displayed in center (640 x 480 LCD)
Voice annotation Voice annotation 60 seconds maximum recording time per image
Image and data storage
Storage medium:


 
SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations or 3000 basic (.bmp) IR images)
File formats:

 
Non-radiometric (.bmp) or fully-radiometric (.is2). No analysis software required for non-radiometric (.bmp) files
Export file formats:
 
JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF and EMF
Software: w/SmartView software
 
 
General Specifications
Temperature
 
Operating: -10°C to 50°C (14°F to 122°F)
Storage: -20°C or 5C (-4°F to 122°F)
Relative humidity 10% to 90% non-condensing
Display
 
9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto)
Controls and adjustments
 
User selectable temperature scale (C°/°F)
Language selection
Time/Date set
Emissivity user selectable Hot Spot and Cold Spot on the image. The Ti25 allows user to adjust palette, alpha blend, level, span, PIP, and emissivity on a captured image before it is stored.
Software SmartView full analysis and reporting software included
Power
Battery:
 
Internal rechargeable battery pack (included)
Battery life:
 
3 to 4 hours continuous use (assumes 50% brightness of LCD)
Battery charge time using AC adapter/charger and DC car charger:
Two hours for full charge
AC operation/charging AC adapter/charger (110V AC to 220V AC, 50/60Hz). Charges battery while imager is operating. (Universal AC mains adapter included.
Power saving Sleep mode activated after 5 minutes of inactivity, automatic power off after 20 minutes of inactivity
Safety standards
CE directive: IEC/EN 61010-1 2nd Edition Pollution Degree 2
Electromagnetic compatibility
 
EMC directive: EN61326-1
C-Tick: IEC/EN 61326
U.S. FCC: CFR 47, Part 15 Class A
Vibration 2 G, IEC 68-2-29
Shock 25 G, IEC 68-2-29 (2 meter (6.5 ft) drop, 5 sides)
Dimensions 27 cm (H) x 13 cm (W) x 15 cm (L)
10.5 " (H) x 5.0" (W) x 6.0" (L)
Weight 1.2 kg (2.65 ib)
IP rating IP54
Warranty Two-years
Calibration cycle Two-years (assumes normal operation and normal aging)
Supported languages

 
English. Italian, German, Spanish, French, Russian, Portuguese, Swedish, Turkish, Czech, Polish, Finnish, Simplified Chinese, Traditional Chinese, Korean, and Japanese

 


Fluke | Hart | Reed | Yokogawa | EuroSMC | Kyoritsu | Megger | | Tenmars | Tektronix | Amprobe | CIE | Silvertronic |
 Site Map | Search | About Us | Contact Us

 