Rapid-Tech Equipment Logo Combo Kit Power Quality Recorder Power Quality Analyzer Multifunction Digital Multimeter

Nationwide - Call 1800 358 531 

   
Fluke/Hart Scientific Logo

Models 1502A and 1504 Reference Thermometer Readouts for RTD, PRT and Thermistor Sensors

 

Specifications

1502A 1504

Temperature Range

-200°C to 962°C (-328°F to 1764°F) Any thermistor range

Resistance Range

0Ω to 400Ω, auto-ranging 0Ω to 1MΩ, auto-ranging

Probe
 

Nominal RTPW: 10Ω to 100Ω
RTD, PRT, or SPRT
Thermistors
 

Characterizations

 

ITS-90 subranges 4, 6, 7, 8, 9, 10, 11
IPTS-68:R0, a, d, a4, and c4
Callendar-Van Dusen:R
0, a, d, and b 
Steinhart-Hart thermistor polynomial
Callendar-Van Dusen:R0, a, d, and b 
 

Resistance Accuracy
(ppm of reading) (1-year)
 

0Ω to 20Ω: 0.0005Ω
20Ω to 400Ω: 25ppm
 
0Ω to 5kΩ: 0.5Ω
5kΩ to 200kΩ: 100ppm
200kΩ to 1MΩ: 300ppm

Temperature Accuracy

±0.004°C at -100°C
±0.006°C at 0°C
±0.009°C at 100°C
±0.012°C at 200°C
±0.018°C at 400°C
±0.024°C at 600°C

 
±0.002°C at 0°C
±0.002°C at 25°C
±0.004°C at 50°C
±0.010°C at 75°C
±0.020°C at 100°C
(Using 10kΩ thermistor sensor,
a=0.04.
Does not include probe uncertainty or characterization errors.)

Operating Temperature Range
Full Accuracy

16°C to 30°C 13°C to 33°C

Resistance Resolution

0Ω to 20Ω: 0.0001Ω
20Ω to 400Ω: 0.001Ω
0Ω to 10kΩ: 0.01Ω
10kΩ to 100kΩ: 0.1Ω
100kΩ to 1MΩ: 1Ω

Temperature Resolution

0.001°C 0.0001°C

Excitation Current

0.5mA and 1mA, user selectable, 2Hz 2µA and 10µA, automatically selected

Measurement Period

1-second

Digital Filter

Exponential, 0 to 60 seconds time constant (user selectable)

Probe Connection

4-wire with shield, 5-pin DIN connector

Communications

RS-232 serial interface standard
IEEE-488 (GPIB) interface (Optional)

Display

8-digit, 7-segment, yellow-green LED; 0.5-inch-high characters

Power

115V AC (±10%), 50/60Hz, 1 Amp maximum
230V AC
(±10%), 50/60Hz, 1 Amp nominal
Specify Voltage when ordering

Dimensions

61mm (H) x 143mm (W) x 181mm (D)

Weight

1.0kg

Calibration

Accredited NIST-traceable calibration provided
 
Note: Temperature ranges and accuracy may be limited by the sensor probe you use.

 


Fluke | Hart | Reed | Yokogawa | EuroSMC | Kyoritsu | Megger | | Tenmars | Tektronix | Amprobe | CIE | Silvertronic |
 Site Map | Search | About Us | Contact Us

 

Rapid-Tech Equipment
ABN 79 883 184 102
1300 Ferntree Gully Road. Scoresby. Victoria 3179
P.O. Box 4243 Knox City Centre. Victoria 3152

Phone: +61 3 9763 3299     Fax: +61 3 9753 2132