Secondary Reference Temperature Standard, PRT, Model 5616 - Specifications

 

Parameter

Value

Temperature Range

-200°C to 420°C

Nominal Resistance at 0.01°C

100Ω ±0.5Ω

Temperature Coefficient

0.003925Ω/Ω/°C nominal

Accuracy Note1

See footnote

Short-term Repeatability Note2

±0.010°C at 0.010°C (see footnote)

Drift Note3

±0.010°C at 0.010°C (see footnote)

Hysteresis

±0.010°C maximum

Sensor Length

50.8mm

Sensor Location

6.0mm ±2.5mm from tip

Sheath Diameter Tolerance

±0.08mm

Sheath Material

INCONEL® 600

Minimum Insulation Resistance

500MΩ at 23°C

Transition Junction Temp Range Note4

-50°C to 150°C (see footnote)

Transition Junction Dimensions

76.2mm x 9.5mm

Minimum Immersion Length Note5
(< 5mK error)

102mm
 

Maximum Immersion Length

254mm

Response Time Note5

8 seconds typical

Self Heating (in 0°C bath)

60mW/°C

Lead-wire Cable Type

Teflon jacketed cable, Teflon insulated conductors, 24 AWG stranded, Silver plated copper.

Lead-wire Length

182.9cm ±2.5cm

Lead-wire Temperature Range

-50°C to 150°C

Calibration

NIST-traceable calibration

 

Note1

 

Accuracy is a difficult term when used to describe a resistance thermometer. The simplest way to derive "accuracy" is to combine the probe drift specification and calibration uncertainty with readout accuracy at a given temperature.

Note2

Three thermal cycles from minimum to maximum temperature, includes hysteresis, 99.8% confidence.

Note3

After 100 hours at maximum temperature, 99.8% confidence.

Note4
 

Temperatures outside this range will cause irreparable damage. For best performance, transition junction should not be too hot to touch.

Note5

Per ASTM E 644
 
Footnote Calibration Uncertainty
Temperature Expanded Uncertainty (K = 2)  

-197°C

0.012°C

Note: Laboratories may periodically reevaluate their uncertainties. Calibration uncertainties depend on the calibration process, the standards used, and the instruments performance.


 

-80°C

0.012°C

-38°C

0.011°C

0°C

0.009°C

156°C

0.011°C

230°C

0.013°C

420°C

0.021°C

 

 