The measuring junction of both the 5649 and the 5650 is
encased in a 0.25-inch (6.35 mm) alumina sheath that can be
ordered in lengths of 20 or 25 inches (50.8 or 63.5 cm) to
fit the specific requirements of your application. A
reference, or “cold,” junction may also be ordered. The
reference junction uses a stainless steel sheath and is 8.25
inches long (21 cm) by 0.188 inches in diameter (4.8 mm).
The thin diameter minimizes the immersion depth needed, but
the extra length ensures you can get all the immersion you
like.
Special tin-plated, solid-copper connecting wires with
ultra-low EMF properties are used to help retain the
integrity of your measurement junction where the probe
attaches to your micro voltmeter or Hart Black Stack.
Each probe comes from a spool of wire that has been sample
tested using fixed-point standards to ensure uncertainties
less than 0.5°C up to 1100°C. From 1100°C to 1450°C, the
uncertainty increases linearly to 3.0°C. If you need greater
accuracy, order an individual calibration with fixed-point
standards to reduce uncertainties to ± 0.15°C up to 962°C,
± 0.25°C up to 1100°C, and increasing linearly to ± 2.0°C at
1450°C.
The probe assembly can be easily disassembled for performing
your own bare-wire calibrations. |