MIT200 Series Insulation Tester - Specifications

Insulation Ranges
Nominal Test Voltage 250V, 500V, 1000V (DC)
Measuring Ranges 10kΩ to 1000MΩ on all ranges
Terminal Voltage open circuit (dc) -0% + 25% of rated voltage
Short Circuit Current 205mA +10mA -5mA
Test Current on Load
 
>1mA at maximum pass values of insulation as specified in
BS 7671, HD 384, IEC 364, and VDE 0413 part 1
Accuracy (at 20°C)

 
±3% of reading ±2 digits up to 10MΩ
±5% of reading ±2 digits up to 100MΩ
±30% of reading up to 1000MΩ

for Models
MIT200, MIT210, MIT220, MIT230

Terminal Characteristics
 
 
Continuity Ranges
Measuring Range 0.01Ω to 100.0Ω (0Ω to 50Ω on analog scale)
Open Circuit Voltage 5V ±1V
Short Circuit Current 205mA ± 5mA (0Ω to 10Ω) > 20mA (0Ω to 100Ω) Ω
Accuracy (at 20°C)
 
±0.01Ω to 9.99Ω ±5% ±2 digits
±10.0Ω to 99.9Ω ±5% ±2 digits

for Models
MIT200, MIT210, MIT220, MIT230

Zero Offset Adjust 0Ω to 9.99Ω
Continuity Buzzer Operates at < 2Ω
 
 
Specifications
Default Voltmeter > 25V AC or DC is applied display will operate as a voltmeter
Test Inhibit If more than 50 volts is detected, testing will be inhibited
Voltmeter Range 25V to 600V at 50/60Hz and DC
Voltmeter Accuracy 25V to 450V AC/DC (±1% ± 1 digit)
450V to 600V AC/DC (±2% ± 1 digit)
Auto Power Down Operates after 10 minutes if left in standby mode
Automatic Discharge

 
After an insulation test the item under test will be discharged automatically. Any voltage present will be indicated on the display so that the discharge can be monitored.
 
 
Environmental Specifications
Operating Temperature -10°C to +55°C
Storage Temperature -25°C to +65°C
Operating Humidity 93% R.H. at +40°C maximum
EMC In accordance with IEC 61326-1
Environmental Protection IP40
 
 
Safety
Meets the requirements of EN 61010-1 CAT III 600V, phase to earth
Terminal Fuse 500mA (fast blow) 600V, 32mm x 6mm, ceramic HBC 50kA minimum.
Automatic Discharge

 
After an insulation test the item under test will be discharged automatically. Any voltage present will be indicated on the display so that the discharge can be monitored.
 
 
General Specifications
Power Supply (battery) Six 1.5V Alkaline type 'AA' (LR6) batteries
(Rechargeable NiMH cells may be used)
Battery Life 3000 consecutive tests (5 seconds per test) on any test using 2Ah batteries
Dimensions 195mm (L) x 98mm (W) x 40mm (D)
Weight 550g approx.

 