Specifications
(@ 23°C,
5kV) |
| Test Voltage Ranges |
250V, 500V, 1000V, 2500V, 5000V |
Test Voltage Accuracy
|
±5% at 1TΩ
±20% at 10TΩ |
| Guard |
2% error guarding 500 kΩ with
100MΩ load |
Display
|
|
Digital Display: |
10kΩ to 15TΩ (3-Digits) |
|
Analog Display: |
100kΩ to 1TΩ |
|
| Short Circuit/Charge Current |
3mA at 5kV |
| Capacitor Charge Time |
< 3 seconds per µF at 3mA to
5kV |
| Capacitor Discharge Time |
<120ms per µF to discharge
from 5000V to 50V |
| Capacitance Measurement above 500V |
10nF to 50µF (depending on
test voltage) |
| Capacitance Measurement Accuracy |
±5% ±5nF |
| Voltage Output Accuracy (0°C
to 30°C) |
+4%, -0% ±10V of nominal test
voltage at 1GΩ load |
| Current Measurement Range |
0.01nA to 5mA |
| Current Measurement Accuracy |
±5% ±0.2nA at all voltages |
| Interference Rejection |
1mA RMS per 250V test voltage up to a maximum of
2mA |
| Timer Range |
Counts up to 99 minutes from start of test |
| Test Regimes |
Auto IR |