Logo of Rapid-Tech EquipmentRapid-Tech Equipment, Australia's leading supplier of quality test equipment.

Home Up Gauss Current Measurements

F.W. Bell, A Division of Bell Technologies Inc.Current Meters & Current Gun Series/Meters & Probes


Current Meter Model mA-2000
ma2000.jpg (50862 bytes)
Description

Advanced patent pending design accurately measures DC and AC currents from 0 to 2000 mA. Simply clamp the retractable probe on the conductor being measured without breaking the circuit. Easy-to-read 31/2 digit LCD. An analog output is provided for connection to an oscilloscope. Comes complete with batteries, optional battery eliminator, hard carrying case and instructions.

Features

  • Measures low level DC & AC currents from 0 to 2000 mA with resolution as low as 0.1mA
  • Basic DC accuracy of 1% of reading
  • True RMS measurement
  • Frequency range DC to 250 kHz
  • Built in 31/2 digit display
  • BNC analog output for connection to oscilloscope or recorder
  • Simple clamp-on operation
  • Supplied with optional AC power adapter and hard carrying case

 Typical Applications

  • Troubleshooting 4-20 mA control loops
  • Isolating faults on electronic circuits
  • Verification of power supply currents
  • Automotive computer control diagnostics
  • Measuring ground current
  • Low current measurements in R&D laboratories

    Download Data Sheet (PDF 209.3kBytes)

Specifications

 
Range  
     Low 0-200 mA (DC or RMS AC)
     High 0-2000 mA (DC or Peak AC)
Resolution  
     Low Range 0.1 mA
     High Range 1 mA
Frequency Range dc to 100 kHz
     ac Low dc to 200 Hz
     ac High 200 Hz  to 100 kHz
     -3 dB 250 kHz
Output  
     Analog 1 mV/mA
Connection BNC
Accuracy  
     dc 1% of reading
     ac - up to 200 Hz 2% of reading
Repeatability 0.5% of reading
Readout 3 1/2 digit LCD
Output (Analog) 1 mV/mA
Output (Connector) BNC
Output (Noise) <100uV RMS
Influences On Accuracy  
     Temperature Coefficient 0.01%/oC
     Adjacent Conductor <100uA/A
Operating Temperature 0oC to 50oC
Storage Temperature Range -25oC to + 70oC
Battery Two 9V Alkaline (NEDA 1640 A)
Battery Life (Typical) 15 hours
Safety IEC 1010 Cat 2 300 V

Pollution degree 2

Aperature Size 0.21 inches (5.3 mm)
Size  
Probe Dimensions: Meter Dimensions:
6.25 inches (15.9 cm) length 5.2 inches (13.2 cm) length
1.2 inches (3.0 cm) diameter 5.3 inches (13.5 cm) width

1.5 inches (3.8 cm) height

Current Gun Series/Meters & Probes

The Current Gun Series of hand-held, noncontact Meter and Probes includes models for a wide variety of applications. The meter has a digital readout located in the normal line of sight in the handle, while the probes are used in conjunction with a multimeter, scope or recorder. All models are for use on conductors up to 3/4inch in diameter.Fw.gif (2005 bytes)

Specifications

Model CG-100D

  • 3-1/2 digit LCD with 5 second readout hold
  • DC/AC Current Range: ±200 A FS
  • Basic Accuracy:  ± 0.75% F.S. to 100A, ± 3% of reading, 100A to 200A
  • Analogue Output: ±2.0V/200A, ±1.0% of reading (plus above stated accuracy)
  • Frequency Response: dc to 1 kHz (readout ac mode 20 Hz to 1 kHz)

Model CG-120A

  • DC/AC Current Ranges: ±50A FS, ±500A FS
  • Basic Accuracy: ±5% of reading
  • Overange Capability: 50 A Range-300% (150A) Accuracy stated above plus ±1% of reading, 500 A range-None
  • Analogue Output: ±0.5V/50A ±0.5V/500A
  • Frequency Response: dc to 1 kHz

Model CG-100A

  • Basic Accuracy: >100A, ±2.0% FS ± 0.9A, ±3.0% of overrange,± 0.9A
  • 65 Hz-1 kHz, 100A add ±6% of reading
  • Analogue Output: ±1.0V/10A, ±1.0V/100A
  • Frequency Response: dc to 1 kHz
Y8100 AC/DC Current Probe
Y8100

Description
The F.W. Bell Y8100 is an exact replacement for the Fluke Model Y8100 clamp-on current probe.  It can be used with a digital multimeter or oscilloscope to measure dc, ac or composite (AC/DC) currents.  The ergonomic pistol shape sets the standard for hand-held comfort. Two ranges, 20 A and 200 A, produce a 2 V output at full current range.  An indicator light turns on when the battery voltage is too low for proper operation.

Ranges  
     Low 20 A ac or dc
     High 200 A ac or dc
Full Scale Output 2V
Basic Accuracy  
     DC to 65 Hz <100 A: +2% of range     

>100 A: +3% of range

     65 Hz to 100 Hz <100 A: add +3% of reading

>100 A: add +6% of range

Calibration cycle 1 year
Frequency response dc to 1 kHz
Recommended load > 1 mW, 100 pF
Temparature range +15oC to +35oC for specified accuracy

-10oC to +50oC for storage & operation at reduced accuracy

Voltage rating  
     Core to ouput 600 Vdc or 480 Vac
     Output to ground 42 Vdc or 30 Vac
Aperature Size 0.75 inches (19 mm) diameter
Weight 14 ounces with batteries
Batteries four "AA" cells
Battery Life Alkaline: 20 hours continuous
Case Material Frame retardant ABS plastic
Color  Black

For additional information, or to order, call Rapid-Tech today