Model SD-4214
Hot Wire Thermo-Anemometer/Logger |
|
|
|
|
Air Velocity Meters |
|
 |
Features
- Measures air velocity as well as temperature with a type 'J'
or type 'K' thermocouple probe.
- Hot wire probe for precise low air velocity measurements.
- Data Hold and Min/Max record.
- Real-Time data logger with integral 2GB SD memory card
(optional).
- RS-232 and USB interface.
- Air velocity is measured in m/s, ft/m, km/h, mph or knots.
- Temperature in °C or °F switchable.
- Air Velocity Range: 0.2 to 25.0 m/s.
- Type 'J' thermocouple range: -50°C to
1200.0°C.
- Type 'K' thermocouple range: -50°C to
1300.0°C.
|
|
|
Air Velocity |
|
Measurement |
Range |
Resolution |
Accuracy |
|
m/S |
0.2 to 5.0
m/S |
0.01 m/S |
±(2% + a) of reading
or
±(1% + a) of full scale |
| 5.1 to 25.0
m/S |
0.1 m/S |
|
Km/h |
0.70 to
18.00 Km/h |
0.01 Km/h |
| 18.0 to
72.0 Km/h |
0.1 Km/h |
|
Mph |
0.50 to
11.20 mph |
0.01 mph |
| 11.2 to
44.7 mph |
0.1 mph |
|
Knots |
0.040 to
9.70 knots |
0.01 Knots |
| 9.7 to 38.8
knots |
0.1 Knot |
| FPM |
40 to 3940
FPM |
1 FPM |
|
|
|
|
|
|
Ait Temperature |
|
Measuring Range |
°C to 50°C (0°F to 122°F) |
|
Resolution |
0.1°C / 0.1°F |
|
Accuracy |
±0.8°C (±1.5°F) |
|
|
|
|
|
|
Thermometer Specifications |
|
Sensor Type |
Resolution |
Range |
Accuracy |
|
Type K |
0.1°C |
-50.0°C to 1300.0°C |
±(0.04% + 0.5°C |
| -50.1°C
to -100.0°C |
±(0.04% + 1°C |
|
0.1°F |
-58.0°F to 2372.0°F |
±(0.04% + 1°F |
|
-58.1°F to -148.0°F |
±(0.04% + 1.8°F |
|
Type J |
0.1°C |
-50.0°C to 1200.0°C |
±(0.04% + 0.5°C |
| -50.1°C
to -100.0°C |
±(0.04% + 1°C |
|
0.1°F |
-58-0°F to 2192.0°F |
±(0.04% + 1°F |
|
-58.1°F to -148.0°F |
±(0.04% + 1.8°F |
|
|
|
|
Above specification tests under the
environment RF Field Strength less than 3 V/M and frequency
less than30 MHz only. |
|
|
|
|
|
Specifications |
|
Circuit |
Custom microprocessor LSI circuit |
|
Display |
52mm x 38mm LCD with backlight |
|
Air Velocity Units |
m/S, Km/h, FPM, Knots, Mph |
|
Temperature Units |
(°C, °F) |
|
Auto Sampling Time |
1, 2, 5, 10, 30, 60, 120, 300, 600, 1800, 3600 seconds |
|
Memory Card |
SD memory card; 1GB to 16GB |
|
Sampling Time of Display |
1 second approx. |
|
Data Output |
USB / RS-232 PC Computer interface |
|
Temperature Range |
°C to 50°C (0°F to 122°F) |
|
Resolution |
0.1°C / 0.1°F |
|
Accuracy |
±0.8°C (±1.5°F) |
|
Operating Temperature |
°C to 50°C (0°F to 122°F) |
|
Operating Humidity |
Less than 85% R.H. |
|
|
|
|
|
|
General Specifications |
|
Power Supply |
Six (6) UM3 type 'AA' batteries |
|
Dimensions (Main Instrument) |
203mm (L) x 76mm (W) x 38mm (D) |
|
Dimensions (Telescopic Probe) |
12mm Diameter, 280mm to 940mm Long |
|
|
|
|
|
|
Ordering Information |
|
Model SD-4214 |
Hot-Wire
Thermo-Anemometer including Telescopic Probe, Hard Carrying Case and
Operating Manual |
|
|
|
|
|
|
Ordering Information |
|
Model SD-2GB |
2G SD Card |
|
Model TP-01 |
Type 'K' thermocouple probe |
|
Model USB-01 |
USB cable |
|
Model UPCB-01 |
RS-232 cable |
|
Model SW-U801-WIN |
Data Acquisition Software |
|
|
|
|
|