Rapid-Tech Equipment Logo Combo Kit Power Quality Recorder Power Quality Analyzer Multifunction Digital Multimeter

Nationwide - Call 1800 358 531 

Reed Instruments Logo Model SD-4214 
Hot Wire Thermo-Anemometer/Logger
 
Air Velocity Meters

Model SD-4214  Thermo-Anemometer

 

Features

  • Measures air velocity as well as temperature with a type 'J' or type 'K' thermocouple probe.
  • Hot wire probe for precise low air velocity measurements.
  • Data Hold and Min/Max record.
  • Real-Time data logger with integral 2GB SD memory card (optional).
  • RS-232 and USB interface.
  • Air velocity is measured in m/s, ft/m, km/h, mph or knots.
  • Temperature in °C or °F switchable.
  • Air Velocity Range: 0.2 to 25.0 m/s.
  • Type 'J' thermocouple range: -50°C to 1200.0°C.
  • Type 'K' thermocouple range: -50°C to 1300.0°C.

 

 

Air Velocity

Measurement Range Resolution Accuracy
m/S 0.2 to 5.0 m/S 0.01 m/S ±(2% + a) of reading
or
±(1% + a) of full scale
5.1 to 25.0 m/S 0.1 m/S
Km/h 0.70 to 18.00 Km/h 0.01 Km/h
18.0 to 72.0 Km/h 0.1 Km/h
Mph 0.50 to 11.20 mph 0.01 mph
11.2 to 44.7 mph 0.1 mph
Knots 0.040 to 9.70 knots 0.01 Knots
9.7 to 38.8 knots 0.1 Knot
FPM 40 to 3940 FPM 1 FPM
 
 
Ait Temperature
Measuring Range °C to 50°C (0°F to 122°F)
Resolution 0.1°C / 0.1°F
Accuracy ±0.8°C (±1.5°F)
 
 

Thermometer Specifications

Sensor Type Resolution Range Accuracy
Type K 0.1°C -50.0°C to 1300.0°C ±(0.04% + 0.5°C
-50.1°C to -100.0°C ±(0.04% + 1°C
0.1°F -58.0°F to 2372.0°F ±(0.04% + 1°F
-58.1°F to -148.0°F ±(0.04% + 1.8°F
Type J 0.1°C -50.0°C to 1200.0°C ±(0.04% + 0.5°C
-50.1°C to -100.0°C ±(0.04% + 1°C
0.1°F -58-0°F to 2192.0°F ±(0.04% + 1°F
-58.1°F to -148.0°F ±(0.04% + 1.8°F
 

Above specification tests under the environment RF Field Strength less than 3 V/M and frequency
less than30 MHz only.

 
 
Specifications
Circuit Custom microprocessor LSI circuit
Display 52mm x 38mm LCD with backlight
Air Velocity Units m/S, Km/h, FPM, Knots, Mph
Temperature Units (°C, °F)
Auto Sampling Time 1, 2, 5, 10, 30, 60, 120, 300, 600, 1800, 3600 seconds
Memory Card SD memory card; 1GB to 16GB
Sampling Time of Display 1 second approx.
Data Output USB / RS-232 PC Computer interface
Temperature Range °C to 50°C (0°F to 122°F)
Resolution 0.1°C / 0.1°F
Accuracy ±0.8°C (±1.5°F)
Operating Temperature °C to 50°C (0°F to 122°F)
Operating Humidity Less than 85% R.H.
 
 
General Specifications
Power Supply Six (6) UM3 type 'AA' batteries
Dimensions (Main Instrument) 203mm (L) x 76mm (W) x 38mm (D)
Dimensions (Telescopic Probe) 12mm Diameter, 280mm to 940mm Long
 
 
Ordering Information
Model SD-4214 Hot-Wire Thermo-Anemometer including Telescopic Probe, Hard Carrying Case and Operating Manual
 
 
Ordering Information
Model SD-2GB 2G SD Card
Model TP-01 Type 'K' thermocouple probe
Model USB-01 USB cable
Model UPCB-01 RS-232 cable
Model SW-U801-WIN Data Acquisition Software
 
 


Fluke | Hart | Reed | Yokogawa | EuroSMC | Kyoritsu | Megger | | Tenmars | Tektronix | Amprobe | CIE | Silvertronic |
 Site Map | Search | About Us | Contact Us

 

Rapid-Tech Equipment
ABN 79 883 184 102
1300 Ferntree Gully Road. Scoresby. Victoria 3179
P.O. Box 4243 Knox City Centre. Victoria 3152

Phone: +61 3 9763 3299     Fax: +61 3 9753 2132