| Voltage Probe Set, Red 200 MHz for 190 series |
|
GST inclusive price for Australian Customers is AUD$242.00 |
| |
| |
| |
| |
|
Double insulated safety designed probe for ScopeMeter190 series.
Each probe set includes
600 V CAT III / 1000 V CAT II rated
10:1 Voltage Probe,
Hook Clip for Probe Tip, 4 mm Test Probe for Probe,
Ground Lead with Hook Clip,
Ground Lead with Mini Alligator,
The red Probe Set also includes a
30 V CAT II rated
Ground Spring for Probe Tip.
Attenuation: 10x
Bandwidth: 200 MHz
Max. Input Voltage: 1000 V
Max. Voltage to ground: 600 V CAT III 1000 V CAT II per IEC / EN61010-2-031
Input Resistance: 10 Mohm
Input Capacitance: 14 pF
Compensation range: 10 to 22 pF
Cable Length: 1.2 m
|
 |
| Voltage Probe Set, Grey 200 MHz for 190 series |
|
GST inclusive price for Australian Customers is AUD$242.00 |
| |
| |
| |
| |
|
Double insulated safety designed probe for ScopeMeter190 series.
Each probe set includes
600 V CAT III / 1000 V CAT II rated
10:1 Voltage Probe,
Hook Clip for Probe Tip, 4-mm Test Probe for Probe,
Ground Lead with Hook Clip,
Ground Lead with Mini Alligator,
The grey Probe Set also includes a
30 V CAT II rated
Ground Spring for Probe Tip.
Attenuation: 10x
Bandwidth: 200 MHz
Max. Input Voltage: 1000 V
Max. Voltage to ground: 600 V CAT III 1000 V CAT II per IEC / EN61010-031
Input Resistance: 10 Mohm
Input Capacitance: 14 pF
Compensation range: 10 to 22 pF
Cable Length: 1.2 m
|
 |
| Low Cost, High Quality 100 MHz Oscilloscope probe |
|
GST inclusive price for Australian Customers is AUD$49.50 |
| |
| |
| |
| |
|
100MHz Oscilloscope probe with insulated BNC connector
and switchable x10 & x1 attenuation.
SPECIFICATION
X10 Mode
Attenuation Ratio: 10:1
Bandwidth: DC to 100MHz
Rise Time: 3.5ns
Input Resistance: 10 Megohm when used with oscilloscopes with 1Megohm input impedance
Input Capacitance: Approx. 15 pF
Compensation Range: 10 to 50 pF
Working Voltage: 600V DC including peak AC de-rating with frequency
X1 Mode
Attenuation Ratio: 1:1
Bandwidth: DC to 15MHz
Rise Time: 23.3ns
Input Resistance: 1 Megohm (Oscilloscope input)
Input Capacitance: 46 pF Plus Oscilloscope Capacitance
Working Voltage: 600V DC incl. peal AC de-rating with frequency osition X 10
Cable Length: 1.2 Meters
|
 |
| Relacement Shielded Test Leads for Model 123 |
|
GST inclusive price for Australian Customers is AUD$231.00 |
| |
| |
| |
| |
|
Set of two (one red, one gray) double insulated silicone shielded test leads for noise free measurements.
Specially designed for use with the Fluke ScopeMeter 120 Series.
Compatible with AC120 Alligator Clips and HC120 Hook Clips.
Safety designed ground leads included. Integral strain relieve and extra hard probe tips provide extra long service life.
Features safety designed shrouded plugs and notched tip to prevent probe from sliding.
Length: 1.2m
Bandwidth: 12,5 MHz
Maximum Signal Voltage: 600V rms. CAT III per IEC 1010-2-031
Maximum Voltage to Ground: 600V rms. CAT III per IEC 1010-2-031
Maximum Current: 1A
|
 |
| Replacement Battery for 120 series |
|
GST inclusive price for Australian Customers is AUD$93.50 |
| |
| |
| |
| |
|
Ni-Cad battery pack designed for use with the Fluke ScopeMeter 120 Series and Fluke-43B Power Quality Analyzer.
The battery pack has to be charged in the instrument.
Performing refresh cycles on a regular basis, as provided by the 120 Series ScopeMeter, will strongly contribute to the lifespan of the batteries.
Nominal Voltage: 4.8V
Capacity: 1800 mAh
|
 |
| High Capacity Replacement Battery for 120 series |
|
GST inclusive price for Australian Customers is AUD$154.00 |
| |
| |
| |
| |
|
NiMH battery pack designed for use with the Fluke ScopeMeter 124 and 123 (Fluke 123 support BP130 from Rev 2.0 onwards, see Instrument documentation.
BP130 does not support previous versions of Fluke 123).
The battery pack can be charged in the instrument.
Performing refresh cycles on a regular basis, as provided by the ScopeMeter 123 & 124, will strongly contribute to the lifespan of the batteries.
Nominal Voltage: 4.8 V
Capacity: 3000 mAh
|
 |
| Line Voltage Adapter/Battery Charger for 90 & 120 series |
|
GST inclusive price for Australian Customers is AUD$154.00 |
| |
| |
| |
| |
|
Provides power cord operation and charging for 90 and 120 series ScopeMeters
Australia 240 V ± 10%
Frequency 50 to 60 Hz ± 10%
Output Voltage: 15 V
Output Current: 300 mA max
Output Plug: 5 mm power jack per DIN 45323
Power Consumption: 10 VA Max.
Voltage to Ground: 600 V rms. CAT III per IEC 61010-31
|
 |
| Line Voltage Adapter/Battery Charger for 190 series |
|
GST inclusive price for Australian Customers is AUD$176.00 |
| |
| |
| |
| |
|
Provides power cord operation and charging for ScopeMeter 190 Series ScopeMeters.
Mains (Line Voltage): 230V ± 10%
Frequency 50 - 60Hz ± 10%
Output Voltage: 17.8V DC
Output Power: 15W
Power Consumption: 23.7VA
Max. Voltage to Ground: 600V rms.
CAT III per IEC 1010-1
|
 |
| SCC120 Special Value Kit |
|
GST inclusive price for Australian Customers is AUD$715.00 |
| |
| |
| |
| |
|
Accessories Package, including:
FlukeView ® Software for Windows.
OC4USB Optically Isolated RS-232 Adapter/Cable
ScopeMeter 120 Series Hard Carrying Case (black)
One BB120 Adapter
Dimensions case: W x H x D 40 x 34 x 12.0 cm 15.5 x 13.5 x 4.75 inches
|
 |
| Accessory Kit for 190 series ScopeMeters |
|
GST inclusive price for Australian Customers is AUD$786.50 |
| |
| |
| |
| |
|
C190 Hard Carrying Case
OC4USB Optically Isolated RS-232 Adapter/Cable
SW90W/034E FlukeView ® Software for Windows.
|
 |
| USB interface cable |
|
GST inclusive price for Australian Customers is AUD$275.00 |
| |
| |
| |
| |
|
Connects the optical isolated serial to USB adapter
Supports the Fluke 120 Series, 190 Series ScopeMeter and the 430 Series Power Quality analyzer
Supports Windows XP/2000/Me/98 Second edition
|
 |
| Shielded Banana to Female BNC Adapter |
|
GST inclusive price for Australian Customers is AUD$60.50 |
| |
| |
| |
| |
|
Safety designed female BNC to Shielded Banana Adapter for use with Fluke ScopeMeter 120 Series and Fluke-43B Power Quality Analyzer.
Two adapters come in package.
Maximum Signal Voltage: 300V rms CAT III per IEC 1010-02-031
Maximum Voltage to Ground: 600V rms. CAT III per IEC 1010-2-031
|
 |
| Differential Probe |
|
GST inclusive price for Australian Customers is AUD$935.00 |
| |
| |
| |
| |
|
The DP120 differential voltage probe is designed to make measurements on signals with floating reference. The DP120 has two probes with shrouded banana probe tips (one red, one black) and shielded cable for improved noise immunity. Input impedance between each input to shielding BNC is 5 MO in parallel with 6 pF. Input impedance between the inputs is 10 MO with a capacitance of 5 pF.
Input: Probes with shrouded banana probe tip
Probe length: 1.5 meter (60 inch)
Maximum Input Voltage to Ground: 600V rms CAT III per IEC 1010-2-031 / 1000Vrms CAT II, per IEC 1010-2-031
Maximum Differential Voltage: 1000V DC or1000Vrms or 1200V (DC + ACpeak)
Output Cable: Safety designed 0.5m (5ft) BNC Cable
Attenuation: 200x and 20x
Bandwidth: DC to 20 MHz (-3 dB)
Accuracy: ±2.5%
Rise time: 17.5 ns
CMRR: 200x: @ 60 Hz = 80dB, @ 1 MHz = 50 dB 20x: @ 60 Hz = 70dB, @ 1 MHz = 40 dB
Battery type: Alkaline 9 volt, NEDA, IEC6LR61
Battery life: 8-hour operation, 400-hour stand by
Power Adapter: PM 8907/80n (optional)
Included Accessories: AC85A Large Jaw Alligator Clips and AC83 Pin-Grabber Test Clips
|
 |
| Isolated Trigger Probe |
|
GST inclusive price for Australian Customers is AUD$935.00 |
| |
| |
| |
| |
|
Designed for use with Fluke ScopeMeter 123.
The probe connects to the optical port of the ScopeMeter 123, and features isolated external triggering, for measurements that require external triggering or triggering on floating reference signals.
Probe length is 1.2m (48 inch). The probe includes a hookclip with ground lead, and a 9-Volt Alkaline battery. Input impedance is 10MO in parallel with 15pF.
Trigger level: TTL compatible (High = 2V, Low = 0.8V)
Minimum pulsewidth: 7 µs
Maximum frequency: 50 kHz
Maximum signal voltage: 600 Vrms, CAT II per IEC1010-2-031
Maximum voltage to ground: 600 Vrms, CAT II per IEC1010-2-031
Input resistance: 10 MW ±10 kW
Battery type: Alkaline 9 volt, NEDA, IEC6LR61