Reed Calibrators



    Reed CC-421
    Voltage/Current Calibrator
    $478.00

    Reed CC-421

      Voltage/Current Calibrator


      GST inclusive price for
      Australian Customers is AUD $525.80

      Remove from Cart Add to Cart

    CALIBRATOR, VOLTAGE/CURRENT, DUAL RANGE
  • Source and measure voltage and current
  • Current calibrator drives loads up to 500O
  • 13mm LCD display
  • Includes test leads

    SPECIFICATIONS:
    Current Source: 0 to 24 mA (2 ranges)
    Current Measure: 0 to 24 mA (2 ranges)
    Voltage Source: -199.9 to +199.9 mV DC
    Dimensions: 185 x 78 x 38mm
    Weight: 265g




    Reed CC-422
    Loop Calibrator
    $398.00

    Reed CC-422

      Current Loop Calibrator


      GST inclusive price for
      Australian Customers is AUD $437.80

      Remove from Cart Add to Cart

    CURRENT LOOP CALIBRATOR, 0-24 mA
  • Adjustable 0 to 24mA current source, 2 ranges
  • Current calibrator drives loads up to 500O
  • 13 mm LCD display
  • Includes test leads

    SPECIFICATIONS:
    Range: 0 to 19.99 mA; 0 to 24.0 mA
    Resolution: 0.01 mA; 0.1 mA
    Sampling Time: 0.4 second
    Dimensions: 185 x 78 x 38mm
    Weight: 265g




    Reed VC-01
    Temperature Simulator
    $530.00

    Reed VC-01

      Temperature Simulator


      GST inclusive price for
      Australian Customers is AUD $583.00

      Remove from Cart Add to Cart

    Temperature Simulator
  • Provides a quick and easy way for checking the calibration of Thermocouples
  • Includes test leads, soft carrying case and batteries

    Specifications
    Voltage Range/Resolution:

    -10.00 to 110.00mV/0.01mV;
    -100.00 to 1100.0mV/0.1mV
    Resistance Range/Resolution:
    0.0 to 400.0 ohms/0.1 ohm
    Thermocouple Range
    Resolution: R:-40 to 1760°C/1°C
    S:-20 to 1760°C/1°C
    B: 400 to 1800°C/1°C
    E: -200.0 to 1000.0°C/ 0.1°C
    K: -200.0 to 1370.0°C/0.1°C
    J: -200.0 to 1200.0°C/0.1°C
    T: -200.0 to 400.0°C/0.1°C
    N: -200.0 to 1300.0°C/0.1°C
    Thermo-resistance
    Range/Resolution: Pt100: -200.0 to 850.0°C/0.1°C
    Cu50: -50.0 to 150.0°C/0.1°C
    Accuracy: ±0.05% setting value




    Reed VC04
    Voltage/Current Simulator
    $530.00

    Reed VC04

      Voltage/Curent
      Simulator


      GST inclusive price for
      Australian Customers is AUD $583.00

      Remove from Cart Add to Cart

    Voltage/Current Simulator:
  • Combines Voltage and Current Source and Read Functions into One Instrument.
  • Combines voltage and current source and read functions
  • 5-digit LCD readout
  • ±0.05% accuracy
  • Automatic calibration
  • User selectable auto power-off
  • Includes test leads, soft carrying case and batteries

    SPECIFICATIONS:
    Output function
    Voltage Range: 10V
    Output Range: 0.00 to 11.000V
    Resolution: 1mV
    Accuracy: ±0.05% setting
    Current Range: 20mA
    Output Range: 0.000 to 22.000mA
    Resolution: 0.001mA
    Accuracy: ±0.05% setting + 4µA
    Analogue Transducer: -20mA
    Output Range: 0.000 to -22.000mA
    Resolution: 0.001mA
    Accuracy: ±0.05% setting + 4µA
    Loop Power: 24V
    Accuracy: ±10%
    Power Supply: Single 9V alkaline battery
    Battery Life: Approx. 20 hours
    Ambient Conditions: -10 to 55°C; = 80% RH
    Dimensions: 200 x 100 x 40mm with protective holster
    Weight: 550g w/ holster




    Reed VC05
    Current Loop Calibrator
    $595.00

    Reed VC05

      Current Loop Calibrator


      GST inclusive price for
      Australian Customers is AUD $654.50

      Remove from Cart Add to Cart

    LOOP CALIBRATOR
  • mA sourcing, simulation and measurement
  • 0-28 VDC measurement to check loop voltage
  • 0.02% accuracy and 0.001% of span display
  • Simulate mA and % of span display
  • Selectable step or ramp outputs
  • 24V loop power supply
  • Includes test leads, soft carrying case & batteries

    SPECIFICATIONS:
    Output function
    Current Range: 0.000 to 22.000mA
    Resolution: 0.001mA
    Accuracy: ±0.05% ±4µA
    Loop Power Range: 24V
    Accuracy: ±10%
    measurement function
    Voltage Range: -0.200 to 28.000V
    Resolution: 1mV
    Accuracy: ±0.02% rdg. ±2mV
    Current Range: -1.000 to 22.000mA
    Resolution: 0.001 mA
    Accuracy: ±0.02% rdg. ±4µA
    Loop Current Range: 0.000 to 22.000mA
    Resolution: 0.001 mA
    Accuracy: ±0.02% rdg. ±4µA
    Power Supply: Single 9V battery
    Battery Life: Approx. 12 hours
    Dimensions/Weight: 200 x 100 x 40mm/550g




    Reed VC14
    Temperature Calibrator
    $1190.00

    Reed VC14

      Temperature Calibrator


      GST inclusive price for
      Australian Customers is AUD $1,390.00

      Remove from Cart Add to Cart

    TEMPERATURE CALIBRATOR
  • Automatic cold-end temperature offset
  • 2-wire/3-wire/4-wire connectionis user-selectable
  • 6-digit LCD readout
  • ±0.02% accuracy
  • Automatic calibration
  • User selectable auto power-off
  • Includes test leads, soft carrying case and batteries

    SPECIFICATIONS:
    output function
    Voltage Range/Resolution: -10.000 to 110.000mV/10µV; -0.10000 to 1.10000V/0.01mV
    Resistance Range/Resolution:
    0.00 to 400.00 ohm/00.1 ohm
    Thermocouple Range/Resolution: R: -40 to 1760°C/1°C; S: -20 to 1760°C/1°C; B: 400 to 1800°C/1°C; E: -200.0 to 1000.0°C/ 0.1°C; K: -200.0 to 1370.0°C/0.1°C; J: -200.0 to 1200.0°C/0.1°C; T: -200.0 to 400.0°C/0.1°C; N: -200.0 to 1300.0°C/0.1°C
    Thermo-resistance Range/Resolution: Pt100: -200.0 to 850.0°C/0.1°C; Cu50: -50.0 to 150.0°C/0.1°C
    measurement function
    Voltage Range/Resolution: 0.00 to ±450.00mV/10µV
    Resistance Range/Resolution: 0.00 to 450.00O/00.1O
    Thermocouple & Thermo-resistance Range: Same as per Output Function




    Reed VC15
    Voltage & Current Calibrator
    $1190.00

    Reed VC15

      Voltage & Current Calibrator


      GST inclusive price for
      Australian Customers is AUD $1,390.00

      Remove from Cart Add to Cart

    VOLTAGE & CURRENT CALIBRATOR
  • 6-digit LCD readout
  • Auto calibration
  • Auto power off
  • Includes test leads, soft carrying case & batteries

    SPECIFICATIONS:
    Output function
    Voltage Range: 0.000 to 11.000V
    Resolution: 0.1mV
    Accuracy: ±0.02% rdg. ±0.01% range
    Current Range: 0.000 to 22.000mA
    Resolution: 0.001 mA
    Accuracy: ±0.05% ±0.01% range
    Loop Power Range: 24V
    Accuracy: ±10%
    Measurement function
    Voltage Range: 0.000 to 11.000V
    Resolution: 1mV
    Accuracy: ±0.02% rdg. ±0.01% range
    Current Range: 0.000 to 22.000mA
    Resolution: 0.001 mA
    Accuracy: ±0.02% rdg. ±0.01% range
    Loop Current Range: 0.000 to 22.000mA
    Resolution: 0.001 mA
    Accuracy: ±0.02% rdg. ±0.01% range
    Power Supply: Single 9V battery
    Battery Life: Approx. 12 hours
    Dimensions/Weight: 200 x 100 x 40mm/550g