Specifications |
|
Measuring Range |
Earth
Resistance:0-10-100-1,000Ω
(Min Scale Div 0.1Ω) |
|
|
Earth
Voltage:0-30Volts |
|
Scale |
Earth
Resistance:3-digit logarithmic continuous scale on measuring
dial. |
|
|
Earth
Voltage: Uniform scale on galvanometer. |
|
Accuracy |
Earth
Resistance: |
|
|
±5% of 2Ω(±0.1Ω
or min one div) in range of 0-2Ω |
|
|
±2.5% of
20Ω(±0.5Ω
or min one div) in range of 2-20Ω |
|
|
±2.5% of
200Ω(±5Ω
or min one div) in range of 20-200Ω |
|
|
±5% of
1000Ω(±50Ω
or min one div) in range of 200-1000Ω |
|
|
Earth
Voltage:±5% of full scale |
|
Measuring Frequency |
500Hz |
|
Ambient Temperature Influence |
Variation in indication is within one scale division of
corresponding range against a temperature change of 20±20°C. |
|
Battery Voltage Influence |
Accuracy
is maintained within specified limit even if voltage decreases to
4 Volts under operating conditions. |
|
Earth
Voltage
Influence |
Variation in indication is within one scale division of
corresponding range for earth voltages up to 10 Volts at the line
frequency. |
|
Power
Source |
Four 1.5
Volt batteries (IEC R20P, ANSI D, Mono 1.5 V or equivalent). |
|
Insulation Resistance |
More
than 20MΩat
500 V DC between terminals and case. |
|
Standard Accessories |
Supplied With Instrument: |
|
|
Four 1.5
Volt batteries fitted in Instrument.
Three measuring leads.
Two earth spikes.
One carrying case.
One accessory storage bag. |
|
Optional Accessory |
B9646CG
Auxiliary earthing net (two sheets per unit). |
|
Size |
190mm
(W) x 122mm (H) x 124mm (D) |
|
Weight |
1.5kg |