751574
600 Amp AC/DC Current Sensor


Specifications

Input Type

Floating input using CT

Rated Currents

DC: ± 600 amps
AC: 600 amps peak

Output Current

400mA (with primary rated current of 600 amps

Current Transformation Ratio

1500:1

Current Direction

Direction of arrow on unit

Amplitude Accuracy

±(0.05% of reading + 40µA) DC

±(0.05% of reading + 40µA) AC 50/60Hz (within three months of calibration)

Reference Conditions

23°C ±5°C, 30% to 70% R.H., AC input as sine-wave
Primary Current: 2A to 600A; In-Phase Voltage: 0V
Supply Voltage: DC ±(15V ±0.75V)
Conductor: Use a straight conductor (dia. 25mm, 300mm or longer), positioned
at the center of the primary hole.

Accuracy 12 Months after Calibration

Add (reading error x 0.5) to the above accuracy values.

Conductor Position Effect

Add ±0.5% of reading

Temperature Coefficient

0.01% / °C (10°C to 18°C, 28°C to 50°C)

Measurement Range

DC to 100kHz (-3dB)

Continuous Maximum Allowable Input

600A peak

Secondary Load Resistance

2.5Ω or higher, 92.5Ω or less
See diagram titled 'Derating of input current based on load resistance below.

 

 

General Specifications  

Primary Current Hole Diameter

26mm

Secondary Conductor

D-Sub 9-pin

Supply Voltage

±15 Volts ±5%

Consumed Power

approx. 5VA (when secondary output current is zero)

Consumed Current

approx. (330mA + output current)

Emissions

Standard EN 61326

Immunity

Standard

EN 61326

 

Operating Temperature

10°C to 50°C (20% to 80% R.H. non-condensing)

Storage Temperature

0°C to 60°C (20% to 80% R.H. non-condensing)

Dimensions

approx. 122mm (W) x 98mm (H) x 57mm (D)

Weight

approx. 1 kg

 

Primary Current Derating by Frequency

Primary Current Derating by Frequency

751574 and 751523 CMRR Characteristic Comparison
(example)

751574 and 751523 CMRR Characteristic Comparison

 
 


Fluke | Hart | Reed | Yokogawa | EuroSMC | Kyoritsu | Megger | | Tenmars | Tektronix | Amprobe | CIE | Silvertronic |