|
Parameter |
Specification |
|
Method of detection |
Mean Value |
|
Display |
LCD (Digital Display: 3999 counts) |
|
Response Time |
Approx 2 seconds |
|
Range Switching |
Manual on AC current range.
Auto range on AC/DC voltage and Resistance ranges. |
|
Data Hold |
On all ranges |
|
Peak Hold |
On AC Current range |
|
Ambient Temperature |
0°C
to 40°C |
|
Relative Humidity |
up to 40°C
RH 85% (no condensation) |
|
Influence of External Magnetic Field |
1A or less at 400A/m |
|
Influence of Conductor Position |
±(2.0% rdg + 3dgt) or less |
|
Safety Standard |
EN61010-1, EN61010-2-031, EN61010-2-032
|
|
Circuit Voltage |
1000Vrms or less |
|
Withstanding Voltage |
5.55kV AC for one minute |
|
Power Supply |
R6P(SUM-3) x 2 or LR6 x 2 |
|
Battery Life |
Approx. 150 hours (continuous) |
|
Consumed Current |
Approx 5mA |
|
Sleep Function |
Approx. 10 minutes after last switch
operation. |
|
Diameter of Measurable Conductor |
54mm at maximum |
|
Dimensions |
105mm (W) x 247mm (H) x 49mm (D) |
|
Weight |
Approx. 470g |
|
Accessories |
User's manual (IM CL150), batteries,
Carrying case (93034) |