Rapid-Tech Equipment Logo Combo Kit Power Quality Recorder Power Quality Analyzer Multifunction Digital Multimeter

Nationwide - Call 1800 358 531 

 Yokogawa Test Instruments Logo

DL750 and DL750P
Digital Oscilloscope - Specifications

 

Main Unit Specifications

Input
 

Type

Plug-in modules (each unit has a built-in A/D converter)

Slots

8

Horizontal Input

 

 







 

Max record length


 

2.5 MW/CH, 50MW total (standard)
10MW/CH, 250 MW total (with /M1 option)
25MW/CH, 500 MW total (with /M2 option)
50MW/CH, 1GW total (with /M3 option)

Time axis accuracy
 

±0.005% (operating conditions: Ambient temperature of
23°C, ambient humidity (RH) of 55 ±10%

Sweep time

500ns to 5 sec/div (in steps of 1, 2, or 5), 10 sec/div,
20 sec/div, 30 sec/div
3, 4, 6, 8, 10, 20, 30 sec/div
1 to 10 min/div (1 min steps), 12 min/div, 15 min/div,
30 min/div.
1 to 10 hour/div (1 hour steps), 12 hours/div
1 day/div, 2 days/div, 3 days/div

Acquisition




 

Mode Normal

Maximum sampling rate 10 MS/s

Mode Envelope
 

Holds peak value at maximum sampling rate, regardless of time/div setting.

Box average

Increases A/D resolution up to 4 bits (up to 16 bits)

Averaging

Number of averages: 2 to 65,536 (2n steps)

Roll

100msec/div or less

Triggers










 

Mode

AUTO, AUTO LEVEL, NORMAL, SINGLE, SINGLE (N), LOG

Pre-trigger

0 to 100% (in 0.1% steps)

Simple trigger source

CH1 TO CH16, DSP1 TO DSP6, LINE, EXT, LOGIC_A, LOGIC_B, TIME

Slope selection



 

CH1 to CH16, DSP1 to DSP6: Rise, fall, rise-fall
EXT (external trigger input), LOGIC_A
LOGIC_B: Rise, fall
Time: Date (year/month/date), hour (hours/ minutes),
time interval (1 minute to 24 hours)

Enhanced trigger source

CH1 to CH16, LOGIC_A, LOGIC_B

Enhanced trigger type
 

A→B(N), A delay B,B> Time, B< Time, B Time Out, Period, Window, OR, Edge On A, Wave Window

Screen

Updating rate

Maximum 30 screens/sec for a single waveform.

Display



 

Display

10.4 inch color TFT liquid crystal display

Effective screen size

211.2mm x 158.4mm

Resolution

800 x 600

Waveform display pixels
 

650 x 512 (in normal waveform mode)
750 x 512 (in wide waveform display mode)

Display modes





 

Split

Single, dual, triad, quad, octal

Zoom

 

Main, Main & Z1, Main & Z1 & Z2, Main & Z2, Z1 only, Z2 only, Z1 & Z2 (Z1 & Z2 are abbreviations for zoom area 1 and zoom area 2, respectively)

X-Y
 

Single mode (X is fixed, Y is set by user), Quad Mode (XY1, XY2, XY3, XY4)

Accumulation

PERSIST Overlays in one color.

 