DL9040 and DL9040L
Digital Scope - Specifications |
|
|
|
|
Basic Specification |
|
Maximum Sample Rate |
5GS/s |
|
Frequency Bandwidth |
500MHz |
|
Max. Record Length |
2.5MW (model DL9040), 6.25MW (model
DL9040L) |
|
Input Channels |
4 (CH1 to CH4) |
|
Input Coupling |
AC, DC, GND, DC50Ω |
|
Input Impedance
|
1MΩ ±1%
approx. 20pF
(when using PB500 probe, 10MΩ 2%, approx. 14pF)
50Ω ±1.5% |
|
Voltage Axis Sensitivity
|
For 1MΩ
Input: |
2mV/div to 5V/div (steps 1-2-5) |
|
For 50Ω
Input: |
2mV/div to 500mV/div (steps 1-2-5) |
|
Maximum Input Voltage
|
For 1MΩ
Input: |
150Vrms CAT I (less than 1kHz) |
|
For 50Ω
Input: |
5Vrms or less and 10V peak or less |
|
DC Offset Max. Setting
when
probe attenuation
set to 1:1
|
2mV/div to 50mV/div: |
±1V for 1MΩ
input |
|
100mV/div to 500mV/div: |
±10V for 1MΩ input |
|
1V/div to 5V/div: |
±100V for 1MΩ input |
|
2mV/div to 50mV/div: |
±1V for 50Ω
input |
|
100mV/div to 500mV/div: |
±5V for 50Ω
input |
|
Vertical (voltage) Axis Sensitivity |
|
DC Accuracy
|
For 1MΩ
Input: |
±(1.5% of 8 div + offset Volt Accy) |
|
For 50Ω
Input: |
±(1.5% of 8 div + offset Volt Accy) |
|
Offset Voltage Axis
Accuracy note 1
|
2mV/div to 50mV/div: |
±(1% of reading + 0.2mV) |
|
100mV/div to 500mV/div: |
±(1% of reading + 2mV) |
|
1V/div to 5V/div: |
±(1% of reading + 20mV) |
|
Frequency Characteristics
notes 1,2 For 50Ω Input and
For 1MΩ Input [from probe tip when
using the dedicated passive probe (PB500)].
(attenuation point -3dB when inputting a sinewave of amplitude ±2
div or equivalent) |
| |
5V/div to 10mV/div: |
DC to 500MHz |
|
5mV/div to 2mV/div: |
DC to 400MHz |
|
Residual Noise
Level note3 |
0.4mV rms or 0.05 div rms, whichever
is larger (typical value)
|
|
A/D Resolution |
8-bit (25 LSB/div) |
Bandwidth Limit
|
For each channel, select Full, 200MHz,
20MHz, 8MHz, 4MHz,
2MHz, 1MHz, 500kHz, 250kHz, 125kHz, 62.5kHz, 32kHz, 16kHz,
8kHz |
|
Maximum Sampling
Rate
Real time sampling mode |
Interleave mode ON: |
5GS/s |
|
Interleave mode OFF: |
2.5GS/s |
|
Repetitive sampling mode: |
2.5TS/s |
|
|
Note 1. |
Please order /P2 option if you use either current probes or
differential probes. |
|
Note 2. |
Choose either one |
|
Note 3. |
PC and SPI triggers are standard. |
|
|
|
| Trigger Section |
|
Trigger Modes |
Auto, Auto Level, Normal, Single, and
N Single |
|
Trigger Source |
CH1 to CH4, LINE, EXT |
|
Window Comparator |
Channels CH1 to CH4, or individual
channels |
|
Trigger Types
|
Edge/State: |
Edge, Edge (Qualified), Edge OR, State |
|
Width: |
Pulse, Pulse (Qualified), Pulse State |
|
Event Interval |
Event Cycle, Event Delay, Event
Sequence |
|
Enhanced
|
TV (NTSC), PAL, HDTV, USER/PC, SPI
(3-wire, 4-wire) serial pattern |
|
|
|
|
Display |
|
Display |
8.4-inch color TFT liquid crystal
display |
|
| Functions (waveform
acquisition/display functions) |
|
Acquisition Modes |
Select from three acquisition modes:
Normal, Envelope, and Average. |
|
Other Acquisition Modes |
High resolution mode, Repetitive
sampling mode, Interleave mode, Interpolate mode. |
|
Interpolate Function |
Interpolates actual sampled data by up
to 1000 times (or up to 2000 times in High-Res. mode) and
increases the time resolution (up to 2.5 TS/s). |
|
X - Y |
Displays XY1, XY2 and T-Y
simultaneously. |
|
Accumulation |
Accumulates waveforms on
the display. Choose Count/Time and Inten/Color. |
|
Snapshot |
Retains the current displayed waveform
on the screen. |
|
|
|
|
|
| Analysis Functions |
|
Search and Zoom
|
Zooms the displayed waveform along the
time (Horizontal Zoom) and voltage (Vertical Zoom) axes.
Independent zooming factors can be applied to two zoom areas.
Search Types: Edge, Edge Qualified, State, Pulse, Pulse Qualified,
Pulse State, Serial Pattern, PC (optional), SPI (optional). |
|
History Memory
|
|
Model DL9040: |
1000 waveforms (2.5 kW) |
|
Model
DL9040L: |
2000 waveforms (2.5 kW) |
|
|
Cursor Measurements |
Vertical, Horizontal, VT, Marker,
Serial |
|
Automatic Measurement
of Waveform Parameter
Function
|
MAX, MIN, HIGH, LOW, P-P,
HIGH-LOW, +OVER, -OVER, RMS, MEAN, Sdev, IntegTY.
C.rms, C.mean, C.Sdev, C.IntegTY, (1/FREQ), FREQ, COUNT, BURST.
+WIDTH, -WIDTH, PERIOD, DUTY, RISE, FALL, DELAY |
|
Telecom Test |
Performs mask test and
eye pattern measurement |
|
Computation Functions |
Computes up to eight traces (CH1 -
CH4/M1 -M4) |
|
Reference Functions |
Display and analysis (computation and
cursors) on up to four traces (M1-M4) of the saved waveform data. |
|
Action-on-trigger
|
|
Modes:
|
OFF, All Condition, (GO/NOGO Zone/Parameter), GO/NOGO
Telecom Test) |
|
Actions: |
Buzzer, Print, Save, Mail |
|
|
|
|
|
|
| Optional Functions |
|
Option /B5 |
Built-in Printer |
|
Option /C8 |
Internal Hard Disk Drive |
|
Option /C10 and C8 |
Ethernet Communication |
|
Option /F5 |
Bus Analysis Function (PC + SPI) |
|
Option /F7 |
CAN+SPI bus analyzer |
|
Option /F8 |
I2+CAN+SPI bus analyzer |
|
|
|
|
Measured value under standard operating conditions after 30-minute
warm-up and performing calibration |
|
|
| Standard Operating Conditions
|
Ambient temperature
|
23°C ±5°C
|
| Ambient humidity |
55°C ±10% |
| Error in supply voltage and frequency |
within 1% of reading |
|
|
|
|
Value in the case of a repetitive signal. The frequency bandwidth of a
single-shot phenomenon is the smaller of the two values. DC to sampling
frequency/2.5 or the frequency bandwidth of the repetitive phenomenon.
When the input section is shorted, the acquisition mode is set to
normal, interleave mode is OFF, accumulation is OFF, and the probe
attenuation is set to 1:1. |
|
|