MV1000 and MV2000 Recorder
Functions Page 1.

Input Components

Number of Inputs

Series MV1000

4, 6,8, 12 or 24 channels

Series MV2000

8, 10, 20, 30, 40 or 48 channels

Measurement Intervals

(A/D integration time is fixed at 1.67ms in High-Speed mode)

Model MV1004

125ms, 250ms or 25ms in High-Speed mode

Model MV1008

Model MV2008

Model MV1006

1s, 5s or 125ms in High-Speed mode

Model MV1012

Model MV1024

Model MV2010

Model MV2020

Model MV2030

Model MV2040

Model MV2048

Points to consider when using
High-Speed Mode



 

When using High-Speed mode (an A/D integration time of 1.67ms) with the MVAdvanced, power supply noise and other factors may cause the measured values to fluctuate.

If this is the case, then measure using Normal mode (A/D integration time of 16.7ms, 20ms or 100ms).

 

 

Input Types

DC Voltage

2omV, 60mV, 200mV, 2V, 6V, 20V, 50V and 1 to 5V

Thermocouple Types

R, S, B, K, E, L, T, N, W, L, U, WRe

RTD Types

Pt100, JPt100

DI

at the contact input or the TTL level

DC Current

with external shunt resistor

 

 

Measurement: Range, Accuracy, and Display Resolution

Input
 

Range and
Type

Measurement Accuracy
(when the integration time is 16.7ms or more)

Display Resolution
 

DC Voltage

1-5V

±(0.05% of reading + 3 digits)

1mV

Thermocouple*

'K'

±(0.15% of reading + 0.7°C)

0.1°C

RTD's

'Pt100'

±(0.15% of reading + 0.3°C)

0.1°C

Note: * Does not include the accuracy of reference junction compensation

 

Display

Display Device

Series MV1000

5.5-inch TFT color LCD (320 x 240 dots)

Series MV2000

10.4-inch TFT color LCD (640 x 480 dots)

Note: the LCD may contain some pixels that are always lighted or that never light, and variations in brightness may occur due to the characteristics of liquid crystals. Please note that these are not defects.

Display Groups

Number of display groups:

Series MV1000

10 groups

Series MV2000

36 groups

Maximum number of channels assigned per group:

Series MV1000

6 channels

Series MV2000

10 channels

Display Colors

Trend/bar

24 available colors

Background

white or black

Trend Display

Display Types

Vertical, horizontal,, horizontal wide, separated horizontal

Bar Graph Display

Direction

Vertical or horizontal

Digital Display

Update rate

1 second

Overview Display

Channel number

Displays a list of all measurement and MATH channels along with their alarm states.

Information display

Alarm Summary, Message Summery, Memory Summery, Report, Relay and Modbus Condition.

Log Display

Display content

Log-in, Error, Transmission, FTP, Web, E-mail, SNTP, DHCP, Modbus

Tag Display

Maximum displayable characters: 16 alphanumeric

Message Display

Maximum displayable characters: 32 alphanumeric

Historical display function: Allows for the display of data stored to internal or external memory.

LCD Screen Saver Function

You can DIM or turn OFF the LCD backlight if there are no keystrokes for a set time (set times: 1, 2, 5, 10, 30 min or 1 hour)

Display Screen Registration

You can assign a name to a display screen and register it. Maximum registration screens: 8

 

 

 

Memory Functions

External Media

Media

Compact Flash (CF) card

Internal Memory

Media

Flash memory

Memory size

80MB or 200MB (selected when purchasing)

 

Save Interval

125ms

1s

5s

10s

60s

120s

Sample Time (with 200MB of memory)

Approx.
217 hours

Approx.
72 days

Approx.
362 days

Approx.
723 days

Approx.
12.1 years

Approx.
24 years

Sample Time (with 80MB of memory)

Approx.
86 hours

Approx.
28 days

Approx.
144 days

Approx.
289 days

Approx.
4.8 years

Approx.
9.6 years

Examples of internal memory sample times (with the Model MV1012 recording only event data files for 12 measuring channels and no calculation channels).

 

Maximum Saveable Data Files

400 (saveable display data files and event data files combined)

Manual Save

Saves data files to the internal memory manually. You can save all data or only selected data to a Destination drive (CF card or USB memory).

Auto Save

Save displayed data to the CF card at set interval.
Save event data to the CF card at a set interval (in Free Trigger mode) Save when finished sampling (when setting the trigger).

Data Formats

When saving to external media, both event data and display data can be saved in either binary or text format (data is always stored to internal memory in binary format).

Manual Sample Data

You can choose when to save measurement/ MATH channel data files to the internal memory or to a CF card.

Report Data

Saves calculation results as data to a CF card at set times. (only available if the unit is equipped with the calculation option).

Types

Hourly, daily, hourly + daily, weekly, daily + monthly

Trigger Function

Data can be saved using Free mode or Trigger mode. When using Trigger mode, the user must set the data length, pre-trigger, and trigger source.

Snapshot Function

Saves the displayed screen image data to a CF card.

Data File Loading

Data files saved to a CF card or to a USB memory (if equipped with the USB option) can be loaded and displayed.

Loading and saving setup data: Settings data can be saved and loaded in Binary format.

USB Interface

USB specification 1.1 host

Ports

Two (front and back)

Connection Devices

104 keyboards (US) compliant with USB HID Class Version 1.1
109 keyboards (Japanese)
External media: USB memory (not all types of USB memory are guaranteed to work).

 