MV1000 and MV2000 Recorder
Options

 

Alarm Output

Alarm Output Relays
 Options (/A1,/A2, /A3, /A4)

Activates the relay output on the rear panel when an alarm occurs

Alarm Output Points

Choose from 2, 4, 6 or 12 (only with the MV2000 series)
(not installable on models MV1008 or MV1024)

 
 

Serial Communication

Options (/C2, /C3) Media

EIA RS-232 (/C2) and RS-422/485 (four-wire) (/C3) compatible

Protocols Implemented

The dedicated protocol and the Modbus (master/slave) protocol

Settings/Measurement Server Functions

Using the dedicated protocol, the following functions are available.

Settings and commands equivalent to the unit's key commands

Data output

Modbus master/slave functions

Loads data from other devices using Modbus protocol. (the calculation option (/M1) or the external input channel option (/MC1) is required to load data).

 
 

Fail/Status Output Relay

Option (/F1)

Activates a relay output upon the detection of a CPU abnormality on the MV or a set condition.

 
 

Calculation Function

Option (/M1)

Performs calculations as well as displays and records the trends or numeric values of calculation channels listed below.

 

Maximum No. of Calculation Channels

Model MV1004

12 channels

Model MV1006

24 channels

Model MV1008

12 channels

Model MV1012

24 channels

Model MV1024

24 channels

Model MV2008

12 channels

Model MV2010

60 channels

Model MV2020

60 channels

Model MV2030

60 channels

Model MV2040

60 channels

Model MV2048

60 channels

Maximum Equation Length

120 characters

Calculation Types

General Calculations

Basic arithmetic, square root, absolute value,

common logarithm, natural logarithm, exponent,

power, relational operations (<, ≤, >, ≥, =, ≠),

logical operations (AND, OR, NOT, XOR)

Statistical Calculations

TLOG (maximum value, minimum value, and P-P

value for time series data)

Special Calculations

PRE, HOLD(a):b, RESET(a):b, CARRY(a):b

Conditional Statement

[a?b:c]

Max. Settable Constant

60 (K01 to K60)

Report Function

Report Types

Hourly, daily, hourly + daily, daily + weekly,

daily + monthly

Calculation Types

Reports can be calculated using a combination of up to four of the following:

Average, maximum value, minimum value,

integrated value, and instantaneous value.

 
 

RTD Input/3-wire Isolated RTD Input

Cu10/Cu25 RTD input/3-wire Isolated RTD Input
               Option (/N1)

Enables the use of Cu10 and Cu25 inputs in addition to the standard inputs.
 

 
 

3-Wire Isolated RTD Input

3-wire Isolated RTD Input
             Option (/N2)
 

All RTD terminals (A, B, and b) are isolated.
Note: Only available with Models MV1006, MV1012, MV2010, MV2030, MV2040 and MV2048.

 
 

External Input

External Input
                Option (/N3)




 

Enables the use of the following thermocouples and RTD's in addition to the standard inputs.

Thermocouples (TC)

Kp vs Au7Fe, PLATINEL, PR40-20, NiNiMo, W/Wre26, TypeN(AWG14).

RTD's

Pt25, Pt50, Ni100(SAMA), Ni100(DIN), Ni120, J263*B, Cu53, Cu100.

 
 

Remote Control

Remote Control
               Option (/R1)

The MV models can be controlled through contact input (up to eight (8)  inputs can be set).

 
 

24V DC Transmitter Power Supply

24V DC Transmitter Power
Supply
               Options (/TPS2*),
                              (/TPS4*)

 

Output Voltage

22.8 to 25.2V DC (for rated current load)

Rated Output Current

4 to 20mA DC

Max. Output Current

25mA DC (over-current protection level: approximately 68mA DC).

*/TPS2

is only available for MV1000 Series

*/TPS4

is only available for MV2000 Series

 
 

Pulse Input

Pulse Input
               Option (/PM1)

 

Contact and open-collector pulse input is possible through the use of special remote input terminals. The calculation (/M1) and remote control (/R1) options are included in with the pulse input option.

Number of Inputs

3 channels (however, if the remote control input terminals are used for pulse input, then up to 8 channels can be made available).

Input Methods

Photocoupler isolation (no isolation between channels). Internal isolated power supply (approx. 5V).

Input Types

Dry contact, open collector (TTL or transistor)

 
 

Input Value Correction

Input Value Correction
             Option (/CC1)

Ten-segment linearizer approximation can be used on every measurement channel to correct input values.

Settable Points

2 to 16 (settable broken-line points)

 
 

Channel Expansion

Channel Expansion
                 Option (/MC1*)
 

You can use the Modbus master function to load data from other devices, and set data through the use of communication input commands. Additional channels are provided for communication input.

Note*

This option only available with Models MV2010, MV2020, MV2030, MV2040 and MV2048.

Note 1

When equipped with external input channel option, the High-Speed mode measurement interval is unavailable.

External Input Channels

240 channels (channel numbers 201 to 440)

 