MV1000 Model, Suffix and Option Codes

Model Code
 

Suffix Code

Optional Code

Description
 

MV1004

 

 

4

channel 

125ms

Fast sampling mode:

25ms

MV1006

 

 

6

channel 

1s

Fast sampling mode:

125ms

MV1008 Note 9

 

 

8

channel 

125ms

Fast sampling mode:

25ms

MV1012

 

 

12

channel

1s

Fast sampling mode:

125ms

MV1024 Note 9

 

 

24

channel

1s

Fast sampling mode:

125ms

Internal Memory

-1

 

Standard Memory 80 MB

-2

Large Memory 200 MB

External Media

-4

CF Card (with Media) + USB

Language

-2

English/German/French

-4

Korean

Input Terminal

-1

Clamped Terminal

-2

Screw Terminal (M4)

Power Supply

-1

100V AC, 240V AC

-2

12V DC Note 1

-3

Rechargeable Battery Note 1

Power Cord

D

Power Cord UL/CSA Standard

F

Power Cord VDE Standard

R

Power Cord SAA Standard

Q

Power Cord BS/PSB Standard Note 11

H

Power Cord GB Standard

P

Power Cord EK Standard Note 10

W

Power Cord without AC Adapter Note 2

Options

 

/A1

Alarm Output 2 points Note 3 and Note 9

/A2

Alarm Output 4 points Note 3 and Note 9

/A3

Alarm Output 6 points Note 3  Note 4 and Note 9

/C2

RS-232 Interface Note 5

/C3

RS-422/485 interface Note 5

/F1

Fail/Status Output Note 4 and Note 9

/M1

Mathematical Functions

/N1

Cu10, Cu25 RTD input/3 leg isolated RTD

/N2

3 leg isolated RTD Note 6

/N3

Extended Input Type (PR40-20, Pt50, etc.)

/R1

Remote Control

/TPS2

24V DC Transmitter Power Supply (2 loops) Note 7 and Note 8

/PM1

Pulse Input Note 8 and Note 9

(including remote control and Maths function)

/CC1

Calibration Correction Function

 

Note 1:

An AC adapter is included as a standard accessory.

Note 2:

'W' can be specified for only 12V DC.

Note 3:

/A1, /A2 and /A3 cannot be specified together.

Note 4:

/A3 and /F1 cannot be specified together.

Note 5:

/C2 and /C3 cannot be specified together.

Note 6:

/N2 can be supplied for only MV1006, MV1012 and MV1024.

Note 7:

In case that /TPS2 is specified, /A2, /A3, /F1 and /PM1 cannot be specified together.

Note 8:

In case that /PM1 is specified, /A3, /M1, /R1, and /TPS2 cannot be specified together.

 

And combination of /A2/F1 cannot be specified together.

Note 9:

In case that MV1008, MV1024 is specified, /A1, /A2, /A3, /F1, /R1, /TPS2 and /PM1 cannot

 

be specified together.

Note 10:

In case that 100V AC, 240V AC is specified, 'P' cannot be specified together.

Note 11:

BS standard is specified only 100V AC, 240V AC.

 

 

 

MV2000 Model, Suffix and Option Codes

Model Code
 

Suffix Code

Optional Code

Description
 

MV2008

 

 

8

channel 

125ms

Fast sampling mode:

25ms

MV2010

 

 

10

channel 

1s

Fast sampling mode:

125ms

MV2020

 

 

20

channel 

1s

Fast sampling mode:

125ms

MV2030

 

 

30

channel

1s

Fast sampling mode:

125ms

MV2040

 

 

40

channel

1s

Fast sampling mode:

125ms

MV2048

 

 

48

channel

1s

Fast sampling mode:

125ms

Internal Memory

-1

 

 

 

Standard Memory 80 MB

-2

Large Memory 200 MB

External Media

-4

CF Card (with Media) + USB

Language

-2

English/German/French

-4

Korean

Input Terminal

-1

Clamped Terminal

-2

Screw Terminal (M4)

Power Supply

-1

100V AC, 240V AC

-2

12V DC Note 1

-3

Rechargeable Battery Note 1

Power Cord

D

Power Cord UL/CSA Standard

F

Power Cord VDE Standard

R

Power Cord SAA Standard

Q

Power Cord BS/PSB Standard Note 11

H

Power Cord GB Standard

P

Power Cord EK Standard Note 10

W

Power Cord without AC Adapter Note 2

Options

 

 

/A1

Alarm Output 2 points Note 3

/A2

Alarm Output 4 points Note 3

/A3

Alarm Output 6 points Note 3

/A4

Alarm Output 12 points Note 3 and Note 4

/C2

RS-232 Interface Note 5

/C3

RS-422/485 interface Note 5

/F1

Fail/Status Output Note 4

/M1

Mathematical Functions

/N1

Cu10, Cu25 RTD input/3 leg isolated RTD

/N2

3 leg isolated RTD Note 6

/N3

Extended Input Type (PR40-20, Pt50, etc.)

/R1

Remote Control

/TPS4

24V DC Transmitter Power Supply (2 loops) Note 7

/PM1

Pulse Input Note 8

(including remote control and Maths function)

/CC1

Calibration Correction Function

/MC1

External Input Function Note 9

 

Note 1:

An AC adapter is included as a standard accessory.

Note 2:

'W' can be specified for only 12V DC.

Note 3:

/A1, /A2, /A3 and /A4 cannot be specified together.

Note 4:

/A4 and /F1 cannot be specified together.

Note 5:

/C2 and /C3 cannot be specified together.

Note 6:

/N2 can be supplied for only MV2010, MV2020, MV2040 and MV2048.

Note 7:

In case that /TPS4 is specified, /A4 cannot be specified together. And combination of /A3/F1

 

cannot be specified together.

Note 8:

In case that /PM1 is specified, /A4, /M1, /R1, and /TPS2 cannot be specified together.

 

And combination of /A2/F1 and /A3/TPS4 cannot be specified together.

Note 9:

MC1 can be specified for only MV2010, MV2020, MV2030, MV2040 and MV2048.

Note 10:

In case that 100V AC, 240V AC is specified, 'P' cannot be specified together.

Note 11:

BS standard is specified only 100V AC, 240V AC.