Rapid-Tech Equipment Logo Combo Kit Power Quality Recorder Power Quality Analyzer Multifunction Digital Multimeter

Nationwide - Call 1800 358 531 

 Yokogawa Test Instruments Logo

MW100 Data Acquisition System
Feature/Benefit - Page 1.

 
System Configuration
 

MW100 Data Acquisition Sytem Configuration

 

A custom MW100 measuring system is comprised of three elements; the MW100 main module, MX Series input/output modules, and MX150 Series base plate. The system can be bench mounted as-is or DIN rail mounted for rack or panel installations. A DIN rail-mounting bracket is included with the MX150.

The input/output modules, base plate, and accessories are all the same as those for the MX100 DAQMASTER series (AC adapter is for the MW100 only).

Input Modules 

10 channel
Pulse Input Module
 
30 channel
General Purpose
Input Module
30 channel
General Purpose
Input Module
 
MX114-PLS-M10 10 channel Pulse Input Module MX110-VTD-L30 (30 channel General Purpose Input Module) Clamp Terminals MX110-VTD-L30/H3 (30 channel General Purpose Input Module) M3 Screw Terminals  
MX114-PLS-M10
 
MX110-VTD-L30
(Clamp Terminal)
MX110-VTD-L30/H3
(M3 Screw Terminal)
 

 

Name Model Number
 of
 Channels
Shortest
 Measurement
 Interval
Description

10 channel pulse input module

MX114-PLS-M10 10 100ms Non-voltage contact/open collector
(10,000 samples/sec Integration speed)

30 channel general purpose input

MX110-VTDL30 30 500ms Clamp terminal, DCV/TC/D1

30 channel module with 500ms scan speed

MX110-VTDL30/H3 30 500ms M3 screw terminal, DCV/TC/D1
 
MX110-UNV-H04 Universal Input Module 4 channels MX110-UNV-M10 Universal Input Module 10 channels MX110-VAR-M06 4-wire RTD and Resistance Module 6 channels MX112--B12-M04 Strain Input Module 4 channels
MX110-UNV-H04 MX110-UNV-M10 MX110-VAR-M06 MX112--B12-M04
MX112-B35-M04 Strain Input Module 4 channels MX112-NDI-M04 Strain Input Module 4 channels MX115-D05-H10 (5V Digital Input Module) 10 channels MX115-D24-H10 (24V Digital Input Module) 10 channels
MX112-B35-M04 MX112-NDI-M04 MX115-D05-H10 MX115-D24-H10
 
 
Name

 
Model

 
Number
of
Channels
Shortest
Measurement
Interval
Description

 

Universal Input Modules

MX110-UNV-H04 4 10ms

DC voltage, thermocouple, 3-wire
RTD, DI (non-voltage contact, Level (5V logic)). Mixed input allowed

MX110-UNV-M10 10 100ms

DC voltage, thermocouple, 3-wire
RTD, DI (non-voltage contact, Level (5v logic)). Mixed input allowed.

4-Wire RTD and Resistance Input Module

MX110-VAR-M06 6 100ms

DC voltage, 4-wire RTD, 4-wire resistance, DI (non-voltage contact, Level (5V logic)). Mixed input allowed.

Strain Input Modules

MX112-B12-M04 4 100ms

Built-in bridge resistance of
120 ohms.

MX112-B35-M04

Built-in bridge resistance of
350 ohms.

MX112-NDI-M04

For connection with an external bridge head & strain gauge type sensor (NDIS connector).

5V Digital Input Module

MX115-D05-H10 10 10ms

Non-voltage contact, open collector, and Level (5V logic). Mixed input allowed.

24V Digital Input Module

MX115-D24-H10 10 10ms

Level (24V logic), Vth=12V

 
 
Output Modules
 
MX120-VAO-M08 Analog Output Module 8 channels MX120-PWM-M08 (PWM Output Module 8 Channels) MX125-MKC-M10 (Digital Output Module 10 Channels)  
MX120-VAO-M08 MX120-PWM-M08 MX125-MKC-M10  
 
Name

 
Model

 
Number
of
Channels
Shortest
Measurement
Interval
Description

 

Analog Output Module

MX120-VAO-M08 8 100ms

Allowed mixed voltage (±10V) and current (4 to 20mA) output.

PWM Output Module

MX120-PWM-M08 8 100ms

Pulse width modulation output module

Digital Output Module

MX125-MKC-M10 10 100ms

"A" contact (SPST)

 
 
Base Plate
 
MX150






 
Base Plate configurations Base plates available for all configurations, from 1 to 6 input/output modules.

When used for the MW100/MX100, you must replace the attachment with the one that comes standard with the MW100/MX100.




 

 
Accessories
 
#772066 Connector covers for open slots. #772066 Connector covers for open slots.
#772075 AC adapter for the DC power model. Operating temperature range: 0°C to 40°C (only for MW100). #772075 AC adapter for the DC power model.
Operating temperature range: 0°C to 40°C (only for MW100).
Input/Output Terminal configurations All input/output terminals are removable except for those of the   MX112-NDI-M04. If multiple terminals are prepared ahead of time, no  re-wiring is needed between measurements.
 
 

Removeable Terminals

 
 
Model Description
772061

Screw (M4) terminal block (reference junction compensation) (RJC included).
For use in combination with 772062. Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10.

772062

Connection cable between input modules and screw terminal block.
Compatible with MX100-UNV-M10, MX115-D05-H10, and MX115-D24-H10.

772063

Plate with clamp terminals (RJC included).
Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10

772064

Clamp terminals. Complete with MX110-UNV-H04.

772065

Clamp terminals. Complete with MX120-VAO-M08, MX120-PWM-M08, and MX125-MKC-M10.

772067

Plate with clamp terminals. Complete with MX110-V4R-M06.

772068

Plate with clamp terminals (Built-in bridge resistance of 120 ohms).
Complete with MX112-Bxx-M04.

772069

Plate with clamp terminals IBuilt-in bridge resistance of 350 ohms).
Compatible with MX112-Bxx-M04.

772080

Plate with screw (M3) terminal (RJC included).
Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10.

772081

Plate with clamp terminal for current with 10 ohm built-in bridge resistance,
applies to MX110-UNV-M10.

772082

Plate with clamp terminal for current with 100 ohm built-in bridge resistance,
applies to MX110-UNV-M10.

772083

Plate with clamp terminal for current with 250 ohm built-in bridge resistance,
applies to MX110-UNV-M10.


Fluke | Hart | Reed | Yokogawa | EuroSMC | Kyoritsu | Megger | | Tenmars | Tektronix | Amprobe | CIE | Silvertronic |
 Site Map | Search | About Us | Contact Us

 

Rapid-Tech Equipment
ABN 79 883 184 102
1300 Ferntree Gully Road. Scoresby. Victoria 3179
P.O. Box 4243 Knox City Centre. Victoria 3152

Phone: +61 3 9763 3299     Fax: +61 3 9753 2132