Description
The MW100 is a scalable, high performance data
acquisition/data-logging platform designed for both
PC-controlled and stand-alone operation under harsh
operating conditions. Open Ethernet connectivity with
web-based configuration and data monitoring functions allow
MW100 to handle a wide range of monitoring and historical
logging functions.
See real-time trends with your web
browser from any PC and no special software. A full range of
input/output modules handle all of your process inputs with
fast measurement speed and high noise immunity for a
rock-solid performance. |
|
 |
|
Featuring
- A wide range of temperatures -20°C
to 60°C. Notes: 1,2,3,4
- Reinforced insulation: between
input terminal and case Note 5,
3700Vrms (for one minute) or 600Vrms/Vdc (continuous).
- A wide variety of network
functions: HTTP, FTP, DHCP, SNTP, E-mail, and others.
- DC power supply (12V to 28 V)
option available.
|
|
Smart Logging
- High speed measurement with a single unit (10
channels/10ms or 60 channels/100ms): Shortest measurement
interval of 10ms.
- Multi-interval: Enables mixing of three different
measurement intervals in a single unit (measurement
intervals can be set for each module).
- Supports CompactFlash (CF) cards Note 6 of
up to 2GB. (continuous data acquisition is possible on 60
channels at 100ms for approximately ten days with a 2-GB
card, or for three months on 60 channels at 1 second).
- MATH function on the main module available with the
/M1 option.
- Collective data acquisition on 360 channels (via
Modbus with the /M1 option).
|
|
Notes: |
|
|
|
|
Note 1:
|
The operating temperature range
for the input modules and main module. The operating
temperature range of the output modules is -20°C
to 50°C. |
|
Note 2:
|
Note that the power cord
supplied with the main module differs depending on the
operating temperature range (see specifications). If the
operating temperature range specification of the supplied
standard power cord does not meet your requirements, it is
recommended that you select a screw-type terminal rather
than the plug type for the main module power inlet, and
supply your own power input cable. |
|
Note 3: |
The operating temperature range
of the AC adapter used with DC power supplies is 0°C
to 40°C. |
|
Note 4: |
Please consult with a
representive for applications involving temperatures below
-20°C. |
|
Note 5: |
The withstand voltage value for
all models (see specifications). |
|
Note 6: |
CF card not installed (sold
separately). |
|
|