TY530 Digital Multimeter |
|
|
|
|

|
Details
- High Precision.
- Basic accuracy 0.09%.
- True RMS measurement.
- Ensured Field Site Safety.
- Conforms to safety standards EN 61010-1,
1000V CAT III, 600V CAT IV.
- Safety shutters for preventing erroneous insertion of test
leads into current measurement terminals.
- Current direct reading function provided by current clamp
sensor (optional accessory).
- Low-pass Filter (LPF).
- Logging-mode memory for 1600 data.
- USB communication, applicable software
(Optional DMM communication package).
- Closed Case Calibration.
- 3-year Warranty.
Standard Accessories (included)
- Four type 'AA' (R6) dry cells, test lead set #98015,
440mA/1000V and 10A/1000V fuses (installed), and instruction
manual.
|
|
|
Accuracy Specifications |
|
Measurement |
Range |
Accuracy |
|
DC Volts |
600.0mV to 1000V |
0.09% + 2 digits |
|
AC Volts (RMS) |
600.0mV to 1000V |
0.5% + 5 digits |
|
DC Current |
600.0µA to
10.00A |
0.2% + 2 digits |
|
AC Current (RMS) |
600.0µA to
10.00A |
0.75% + 5 digits |
|
Continuity Check |
buzzer sounds
at 50Ω ±30Ω or less Range:
600Ω |
|
Resistance |
600.0Ω to
60.00 MΩ |
0.4% + 1 digit |
|
Diode Test |
2.000V |
1.0% + 2 digits |
|
Temperature Note1 |
-50°C to
600°C |
2.0% + 2°C |
|
Capacitance |
10.00nF to
1000µF |
2.0% + 5 digits |
|
Frequency |
10.00 Hz to 99.9 kHz |
0.02% + 1 digit |
|
| |
|
Note1: |
Temperature Probe: Type 'K'
Thermocouple sensor (optional) |
|
|
|
|
|
|
General Specifications |
|
Measurement Functions: |
DC voltage, AC voltage, DC
current, AC current, resistance, frequency, temperature,
capacitance, continuity check, diode test and Low-pass filter
(can be switched on/off) and RMS/MEAN detection.
For AC voltage/current, RMS/MEAN detection can be switched. |
|
Additional Functions: |
Data hold/auto hold/range hold,
maximum/minimum/average values, resistance, relative and
percentage value calculation, memory function, communication
function, logging-mode memory, auto power off and backlight. |
|
Display: |
3.5-digit LCD: 7-segment
Digital display: Main display 6000 counts
Bar graph display: 31 segment
Polarity indicator: "-" appears automatically when the
polarity is negative
Overrange indicator: "OL" appears |
|
Measuring Rate: |
Instrument: 5 times/sec
Frequency: 1 time/sec
Capacitance: max. 0.014 times/sec (1000µF)
Resistance: 2.5 times/sec
Temperature: 0.7 times/sec
Bar graph display: 25 times/sec
DC voltage: 5 times/sec
Diode test: 5 times/sec |
|
Operating Temperature: |
-10°C to
55°C; 80% RH or less (no condensation)
40°C to 55°C; 70% RH or less
|
|
Storage Temperature: |
-30°C to
70°C; 70% RH or less (no condensation) |
|
Temperature coefficient: |
Add the accuracy 0.1/°C
to the basic accuracy at a temperature within
-10°C to 18°C and 28°C
to 55°C |
|
Power Supply: |
Four type "AA" (R6) dry cells |
|
Battery Life: |
Approx. 300 hours (for continuous
DC voltage measurement with Alkaline cells) |
|
Withstanding Voltage: |
6.88kV for 5 seconds (between
input terminals and casing) |
|
Compliance/Standards: |
safety EN61010-1, EN61010-031,
1000V CAT III, 600V CAT IV,
pollution level 2, 2000m max. above sea level
EMC: EN61326-1 Class B, EN55011 Class B Group 1 |
|
Dimensions: |
Approx. 90mm (W) x 192mm (H) x
49mm (D) |
|
Weight: |
Approx. 570g (including batteries |
|
|
|
|