XL120 Series
Datum-Y Portable Data Loggers |
|
Models XL121, XL122 and XL124 portable loggers for maintenance
service |
|
| |
|
 |
Features
- Wide viewing angle 3.5" TFT-LCD with both Digital graph
and Bar graph Displays.
- Auto-set and Auto-run function with use of external
memory.
- Measure current and electrical power with additional
Clamp-on Accessories.
- Thermocouple measurements.
- RTD 3-wire measurements.
- Alarm outputs.
- Trigger function.
- Automatic battery change when power failure occurs.
- Computing function.
Datum-Y Datasheet (PDF)
(documents
are in PDF format and will open in a new window) |
|
|
|
|
Specifications |
|
Parameter |
Specification |
|
Terminal Shape |
Push-lock screw (model XL121, XL122),
M3 screw (XL124)
RTD for model XL121 and XL122 only. |
|
Number of Inputs |
8 channels (XL121), 16 channels
(XL122, XL124) |
|
Measurement Interval |
100ms to 1 hour (8 channel terminal
block is used) |
|
|
200ms to 1 hour (16 channel terminal
block is used) |
|
Storage |
Internal memory (16MB) |
|
External Storage
|
Compact Flash memory card (Type II),
SD card USB memory (only the copy function is supported by USB
memory) |
|
Input (range)
|
DCV (100mV - 50V, 1 - 5V f.s.),
Thermocouples K, E, J, T, L, U, N, W, R, S, B,
RTD's Pt100, JPt100, Digital (Pulse, Logic) (RTD's for models
XL121 & XL122 only) |
|
Functions
|
Alarm output (4ch), Trigger function
(pre trigger/trigger delay), calculation (four arithmetic
operations between 2 channels, linear scaling, Statistical
operation), Average function, Automatic Measurement function. |
|
Communication Function |
LAN, USB, RS-232, RS-485 |
|
|
|
|
General Specifications |
|
Parameter |
Specification |
|
Operating Temperature |
0C to 50C, RH 5 to 85%
(non-condensing) |
|
Storage Temperature |
-20C to 60C, RH 90% or less |
|
Size |
Approx 155mm (W) x 155mm (H) x 55mm
(D) (without projecting parts/rubber boot) |
|
Weight |
Approx 800g (without battery and
rubber boots) |
|
|
|